Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN RSL 100...5$6,090.00
50 FT RG11...3$35.00
Dual Port Coaxial...1$1.65
EZ TM-50-U...9$164.00
ROHN Universal...7$70.38
ROHN 18 inch...4$86.00
24 inch Deluxe...4$34.95
Rohn RSWGB...6$260.00
50 Foot Telescopic...8$282.00
EZ46-3 Pitch...2$3.95
ROHN RSL TOWER...4$33.00
Rohn RSL RGKG...5$430.00
EZ32 Telescopic...8$14.95
ROHN 24 inch...7$88.00
Complete Grounding...4$32.00
Rohn RSL Tower...1$196.00
ROHN 4 inch...8$39.00
ROHN 12 inch...5$84.00
ROHN 65G Section...1$84.95
18 inch Telescopic...10$28.40
EZ32C Telescopic...1$24.95
5' Foot X 1...4$16.30
ROHN Tower...1$38.00
ROHN 25G 5...1$165.00
ROHN Lightning...5$145.00
ROHN RSL 100...6$6,636.00
BNC Male to...3$1.55
ROHN 12 inch...1$45.00
ROHN Lightning...1$69.00
30 Foot Telescopic...1$166.00
Rohn RSL Tower...4$310.00
Rohn RSL Tower...9$1,540.00
4 inch Heavy...9$11.95
100 FT RG11...2$55.00
3 Foot Tripod...1$31.50
Rohn RSL Tower...3$345.00
225 FT RG11...2$99.00
EZ32A Telescopic...6$21.95
ROHN 45G 40...1$1,605.00
75 FT RG11...3$45.00
MCR 4-Way Horizont...1$4.60
RG11 RG7 RG6...1$12.95
Rohn RSL Tower...4$1,150.00
EZ TS-50 Free...2$69.95
50 Foot Telescopic...5$325.00
12 inch Telescopic...4$23.50
ROHN 8 inch...5$79.00
ROHN 25G Tower...1$298.00
ROHN H20 Telescopi...10$75.00
HOLLAND 20...1$2.65
ROHN 65G Tower...2$734.00
Rohn RSL Tower...5$625.00
RG6 Coaxial...4$3.95
ROHN 25G 45G...1$318.00
ROHN 25G 40...2$865.00
ROHN TUF TUG...1$325.00
ROHN 55G Tower...1$420.00
ROHN BGK2G...3$89.00
ROHN 45G 45...1$2,150.00
ROHN 25G Complete...1$4,275.00
Rohn RSL Tower...3$372.00
Rohn RSL Tower...4$156.00
EZ19B Roof...2$18.08
ROHN H50 Telescopi...25$189.00
LNS5000 Big...1$67.95
ROHN 55G Tower...1$332.00
4 inch W type...1$10.95
ROHN 45G Tower...1$162.00
ROHN 25G Tower...1$260.00
30 inch Telescopic...3$24.95
Broadband Digital...1$26.95
Commscope RG11...1$230.00
3 dB Power...1$3.65
Rohn RSL Tower...3$60.50
ROHNJACK G...1$329.00
Telescopic...25$164.00
ROHN 25G Tower...1$97.00
RASK12 Accessory...6$296.00
3S60 620 Plastic...1$108.00
TTRSL100 Safety...6$850.00
Rohn RSL Tower...1$1,345.00
ROHN 25G Assembly...1$186.00
618 Telescopic...1$134.00
ROHN RSL 100...1$6,400.00
Turnbuckle...2$3.05
125 FT RG11...3$59.00
ROHN 45G Assembly...1$290.00
HOLLAND LA...1$14.95
ROHN 25G 80...1$2,300.00
ROHN Tripod...1$284.00
ROHN 25G Tower...1$358.00
ROHN 25G 10...1$156.00
ROHN Leg Mounted...1$165.00
BNC Connector...1$1.45
Dual Port Coaxial...1$1.35
RG6 Underground...1$34.00
Rohn RSL Tower...3$3,710.00
DC Voltage...1$1.95
ROHN 65G 20...1$2,600.00
ROHN 25G Tower...1$289.00
CTB-15 Self...1$8.95
ROHN 65G Tower...1$1,350.00
EZ46-3PO Pitch...1$1.90
ROHN TUF TUG...4$335.00
Rohn RSL Tower...3$58.00
Non-Penetrating...1$24.95
5' Foot by...1$14.50
ROHN 25G Tower...1$205.00
ROHN 25G Adjustabl...1$186.00
Cat6 UTP 550...1$9.00
HOLLAND LA...1$11.95
ROHN 55G 20...1$1,405.00
Holland HPF...1$2.45
53" X 2.00"...1$17.95
Holland G-F81F*...1$0.39
ROHN 25AG 45AG...1$49.00
21" J Pipe...1$19.95
Rohn RSL Tower...1$592.00
3 Foot Roof...1$54.00
ROHN 65G 40...1$5,090.00
Push on F Connector...1$0.79
ROHN NPPK Non...1$469.95
20 dB 2 Port...1$2.89
ROHN 65G 30...1$3,406.00
1/8" Down...1$0.95
Coaxial Cable...1$1.95
FAM-16HR 16...25$2.45
Dual Port Coaxial...1$1.30
36 Inch Roof...1$49.00
Goods Total392$182,649.89
View Cart Check out
Printer View Tell a Friend

5/8 X 8 Foot Ground Rod Galvanized

Price$16.95
Manufacturer CodeGR-8-GAL
Qty
AvailabilityUsually ships in 24 Hrs
ShippingCan ship Canada

Highlights

5/8" x8'

Galvanized

Bulk Quantities Available Here!

GR8GROD 5/8" x 8' Galvanized Ground Rod
Galvanized over Electrolytic Copper On Steel Core, use 5/8 inch Ground Rod Clamp for #6, #4 copper, use 3/4 inch clamp with 7/16 inch steel wire rope (sold separately). Suitable for burial after attachment (see our self amalgamating sealant tape). Use for REV. F Grounding of Tower Base and Down Guys or Telescopic Antenna Masts. Select a ground rod clamp based on conductor to be attached (see details).


REV. F Tower Grounding kits are based on 8 foot ground rod use, REV. G Tower Grounding Kits use 10 foot ground rods (that can only be shipped LTL Freight). REV. F Tower Grounding Kits use #4 Solid or Stranded Copper (use a regular 5/8 inch ground rod clamp), whereas REV. G Tower Grounding Kits rely on 7/16 inch Galvanized Steel Wire Rope (select the 3/4 inch ground rod clamp we sell here).
Specification Sheet
grounding type
Ground Rods
Rate this product.
Product isn't rated yet. Write a review.

Ground your Coaxial Cable System

Commensurate with Coaxial Cable TV Antenna and Satellite TV Splitter Installation, you want to Ground your Cable TV or HDTV Antenna Coaxial Cable System Outside before bringing the TV Cable Inside. This way, Lightning Strikes and Power Surges have an opportunity to arrest before reaching your Satellite Receiver and TV Set(s). The Integral Grounding Block designed onto most Outdoor Use Compatible Satellite Signal Splitter we sell will effectively convey this unwanted Electrical Energy to a Ground Rod via a Copper Ground Wire that you Install (not included). Consult your Local Building Code and NEC for guidance to Properly Grounding your HD TV Antenna, Satellite TV, Cable TV, WI-FI, Wireless Internet, Business Band, CB or Amateur Radio Antenna Installation.

Grounding & Bonding Are Important

Ground Blocks and Proper Grounding are an Important, often overlooked, aspect of Your Over-all Cable TV, HDTV or Satellite Antenna Installation and Safety. Proper Grounding can also Reduce the Reception of Interfering RF Signals. Grounding of Masts, Antennas, Cable TV and other RF Distribution Systems are covered by the NEC. Grounding can be as simple as a 12 AWG Ground Wire connected a short distance away to a 8 foot 5/8" DIA Copper Ground Rod (not supplied) or Bonded to the Existing Power Ground by the Power Meter installed on the side of your Home or Office. You may notice that most new Cable TV, Satellite and TV Antenna Installations are effected in this Manner. However, most State and some Local codes will contain requirements that supercede that of the NEC. Please Refer to Your Local Building and Electrical Codes...