ROHN 55G110R140 140' foot 55G Guyed Tower Complete Kit 110/90 MPH Rated


ROHN 55G110R140 140' foot 55G Guyed Tower Complete Kit 110/90 MPH Rated
Price: $13,028.00

Highlights:

Hot Dip Galvanized
Double Bolted Joints
Zig-Zag Rod Bracing
1-1/2" Steel Tubing
Side Rails
17" Equilateral
Triangular Design
Can be used in:
Self Support Config


Availability: Call to Order or Request Quote
Weight: 2050 lb
Description

ROHN 55G110R140 140' foot 55G Guyed Tower Complete 110/90 MPH Rated Kit
Made in the USA!Made in the USA!
The ROHN 55G110R140 140' foot 55G Guyed Tower Kit comes Complete and Pre-engineered as Specified in the ROHN Catalog for Use at the Rated Height, Antenna Load and Wind Speed indicated. This 55G110R140 Kit is comprised of the following BOM (Less Foundation and Installation) in accordance for use as a 140 Foot ROHN 55G Tower with EPA Ratings (Effective Projected Area) for 110 MPH (Rev. G) and 90 MPH (Rev. F).

This ROHN 55G Tower is to be used in a Guyed Configuration for Wireless Internet, Amateur and Business Radio, SCADA, DBS and Satellite Services, Cellular and Repeater, Smaller Microwave, Narrow Beamwidth Antenna or Broadcast Installations according to Specifications in the ROHN Catalog.
As a Guyed Structure, a 110 MPH Rated ROHN 55G Tower can rise to a Maximum of 300 Feet.
Click on the More Info and Specification Tabs above for all the Information You Need on this Product including EPA (Effective Projected Area wind load permissible of Antenna Surface Area in Square Feet), Foundation, Guying, Assembly and Grounding Detail Information.
This Item Ships LTL Freight ONLY!

 

EPA for Exposure B / Revision G = 23.6 (Sq. Ft.)
EPA for Exposure C / Revision G = 18.9 (Sq. Ft.)
EPA at ( 90 MPH) per Revision F = 17.2 (Sq. Ft.)

 

THE 55G110R140 KIT INCLUDES THE FOLLOWING:
BILL OF MATERIALS: 55G110R140 110/90 MPH RATED PRE-ENGINEERED KIT
QUANTITY PART NUMBER DESCRIPTION
1 APL55G Top Beacon Plate for 55G
14 55G 10' Main Tower Section
14 25JBK Bolt Kit for 55G Tower Section
1 BPC55G Standard Concrete Base Plate
4 GA55GD Guy Wire Bracket Assembly
575 ft 1/4EHS 1/4” Extra High Strength Strand
1,275 ft 3/16EHS 3/16” Extra High Strength Strand
12 PLP-115 Yellow Plastic Guard for Down Guys
6 BG2144 1/4" Big Grip Preform Dead-ends
18 BG2142 3/16" Big Grip Preform Dead-ends
6 3/8THH 3/8" Heavy Duty Thimble
18 5/16THH 5/16" Heavy Duty Thimble
12 1/2TBE&J 1/2" x 12" Turnbuckle Eye-to-Jaw
3 TBSAFETY Turnbuckle Safety Wire and Clamps Kit includes:
(1) 14001 – 1/4” Galvanized Guy Clamp
(1) 1/44GW15 – 1/4” x 15’ Guy Wire
3 GAC3455TOP 81" Guy Anchor with 5 Hole Equalizer Plate
1 AGK1GGX Anchor Rod Ground Kit includes:
(3) 15' of 7/16 EIP IWRC RRL
(3) 5/8" x 10' Galvanized Ground Rod (AKA 6260)
(3) 3/4” Clamp No. 8034 WB (AKA 340016)
(3) CPC.5/.75 Anchor Rod Clamp
3 BGK2GGX Tower Base Section Grounding Kit includes:
(1) 15' of 7/16 EIP IWRC RRL
(1) 5/8" x 10' Copper Clad Ground Rod
(1) 3/4" Clamp Ground Rod Clamp
(1) CPC1.5/2 Tower Section Rail Clamp
3 CPC.5/.75 Anchor Rod Clamp
1 3/4x12PP Concrete Base Plate Pier Pin Insert
1 ASSEMBLY GUIDE Printed Specification/Assembly Guide

Note:

Guyed Towers are limited in Height due to the nature of Antenna and Ice loads versus the Cantilever Nature Of Wind against them, offset by the Downward force of all Downguy tensioned as specified, terminated to a properly embedded Anchor, the weight/size of the Foundation and the cohesive of the soil to prevent skid/pullout and all together to counter a Structural Failure or Tower tip-over moment, as well as the strength of the tower members to withstand these Forces against them. ROHN Tower Kits are designed based on assumptions made regarding Windspeed, EPA (Antenna Load), Ice Load, Transmission Cable Loads, Height, Standard Soil Conditions, Surrounding Environment and Duty (Exposure Categories).
The Pre-packaged Kits contain the parts called for based on this Stock Design. The Stock Design of these Kits does not account for the Variations of Historic Windspeed, Number of Antenna(e) Loading at Specific Height(s), Soil Engineering recommendations, Adjacent Structures, Communications Purpose, or Geo-Political Rules, Laws and Codes That will be Applicable to Your Project.
It is Recommended that you take the time to engage an local Engineer that has the expertise and available Information necessary to evaluate the Stock design for Applicability, and/or Fill Out the Tower Quote Data Sheet Form found by clicking the Specification Tab above and send to 3 Star Inc./ROHN for a review.
*Per Rev G requirements, any structure greater than 10' foot requires a climber safety device.


Specification
Specification Sheet
buyers guide PDF DownloadDownload PDF
specification sheet PDF DownloadDownload PDF
wind speed rating 110

Images

ROHN 55G110R140 140' foot 55G Guyed Tower Complete Kit
ROHN 55G110R140 140' foot 55G Guyed Tower Complete Kit