ROHN 25G Complete 40 Foot 130/ 110 MPH Guyed Tower 25G130R040

Price$3,340.00
Manufacturer Code25G130R040
Top Cap:
Qty
AvailabilityShips in 1 to 3 Days
ShippingCan ship only within USA

Highlights

Hot Dip Galvanized
Double Bolted Joints
Zig-Zag Rod Bracing
1-1/4" Steel Tubing
Side Rails
12-1/2" Equalateral
Triangular Design
Can be used in:
Guyed Config

Bulk Quantities Available Here!

ROHN 25G Complete 40 Foot 130 MPH (REV. G) 110 MPH (REV. F) Guyed Tower
This Product Order Supplies the Following BOM (Less Foundation and Installation) in accordance for Use as a 40 Foot ROHN 25G Tower with EPA's (Effective Projected Area) Ratings for 130 MPH (REV. G) or 110 MPH (REV. F). Refer to Larger Image for EPA Information.

 

 

THIS KIT INCLUDES
25G130R040
QUANTITY PART NUMBER DESCRIPTION
1 25AG2 Top Cap Tower Section
3 25G 10' Tower Section
1 25AJBK Bolt Kit for 25G Top Section
3 25JBK Bolt Kit for 25G Tower Section
1 BPC25G Standard Concrete Base Plate
1 GA25GD Guy Wire Bracket
175 FT 3/16" Guy Wire
3 PLP-115 Yellow Plastic Guard for Guy Wire
6 BG2142 3/16" Big Grip Pre-Formed Deadends
6 5/16THH 5/16" Thimble
3 1/2TBE&J 1/2" x 12" Turnbuckle - Eye-to-Jaw
3 TBSAFETY Turnbuckle Safety Wire and Clamps Kit
3 GAC3455TOP Anchor Rod with 5 Hole Equalizer Plate
1 AGK1GGX

Anchor Rod Ground Kit

This Kit Includes:

(3) 15' of 7/16 EIP IWRC RRL

(3) 5/8" x 10' Galvanized Ground Rod (aka 6260)

(3) 3/4" Clamp No. 8034 WB (aka 340016)

(3) CPC.5/.75 - Anchor Rod Clamp

3 BGK3GGX

Tower Base Section Grounding Kit

This Kit Includes:

(1) 15' of 7/16 EIP IWRC RRL

(1) 5/8" x 10' Copper Clad Ground Rod

(1) 3/4" Clamp Ground Rod Clamp

(1) CPC1/1.25 - Anchor Rod Clamp

3 CPC.5/.75 Anchor Rod Clamp
1 3/4x12PP Pier Pin Insert for 25G Tapered Base
1 ASSEMBLY GUIDE

 

The 25AG2 Top Cap Tower Section is the standard top section for the 25G Tower Series,

but can be replaced with the following options.

 

TOP CAP TOWER SECTION OPTIONS
PART NUMBER DESCRIPTION HEIGHT O.D.
25AG Top Cap 9' 2"
25AG1 Top Cap 9' - 3" 1.66"
25AG2 Top Cap* 9' - 9" 2.25"
25AG3 Top Cap 9' - 3 1/2" 2.25"
25AG4 FLAT Top Cap 8' - 3/16" FLAT
25AG5 Top Cap 8' - 1/2" 2.75"

 

 

This 25G Tower is to be used in a Guyed Configuration according to Specifications in the ROHN Catalog. As a Guyed Structure, a 130 MPH rated Tower can rise to a maximum of 100 feet. Refer to ROHN catalog for Foundation and Grounding Detail Information. Consult ROHN Catalog Links at Footer Section at Bottom of Page for more ROHN 25G Tower Details.

 

This Item Ships LTL Freight ONLY...

Specification Sheet
buyers guide
wind speed rating
130
specification sheet
Rate this product.
Product isn't rated yet. Write a review.

Rohn 25G Series Tower

ROHN 25G Tower series is the Workhorse of America's Large and Small Communications needs; from Governments, Institutions, Space Program, Olympics, TV AM FM Broadcast, Terrestrial Microwave to Business-Band Radio, HAM Radio Operators, to Off-Air Antenna TV and DTV Reception in Fringe areas outside the Suburban Broadcast Area. ROHN fabricates their towers from the highest quality steel. They maintain mill certification on the raw materials they receive to verify the material composition of each structural member. With a focus on quality, their fabrication facility has been awarded Certification by the American Institute of Steel Construction and the Canadian Welding Bureau. They have also been approved by the City of Los Angeles, CA and Clark County, NV as a certified fabricator. They are confident that their facility and staff can produce superior grade towers and poles that will meet your standards and weather the test of time. If you need more information you can always contact us to get support or visit the knowledge base 24/7 for help.

Tower & Foundation Installation

Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the 25G tower. All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance.

Wind Loading

Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a substitution; for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 25G Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.

 


 

ROHN Complete Tower ID Nomenclature

DESIGN NOTES:
1.
Tower designs are in accordance with ANSI/TIA-222-F-1996 and ANSI/TIA-222-G-2005, Class I Structures.
2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain.
3. Designs assume two 1/2" diameter lines on each tower face.
4. Anchor radius is from tower base to intersection of anchor rod with ground.
5. Tower designs and guy chord lengths shown are based on level ground. Initial tensions for guys in pounds at 60º Fahrenheit are shown in ( ).
6. Antenna and mounts are assumed symmetrically placed at the tower top.

PARTS LIST NOTES:
1.
Items listed are required for complete (ground) guyed towers. Base and anchor details will be required for installation on roofs or for sites located on unusual terrains and wind loading criteria, for all roof type installations.
2. Standard guys provided with each standard tower include an additional 6% length.
3. Anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.
4. Installation information and a safety package (P/N: ACWS) are included with each tower


25G Buyers Guide

ROHN 25G Buyers Guide


Download the ROHN 25G Buyers Guide


This Buyers Guide will answer many questions you may have on this Product Line. We have detailed information and Specifications sheets covering many aspects of Various Parts, Accessories and Installation Scenarios.

GUIDELINES FOR THE PREPARATION OF A GEO-TECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geo-technical Engineer.

b) It is not ROHN´s purpose or intent to supersede the Geo-technical Engineer´s knowledge, judgement and/or experience. It is the Geo-technical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geo-technical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geo-technical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressible strengths should be determined.

IV. GEOTECHNICAL REPORT

  • The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

 

 

  1. Soil classification and elevations
  2. Standard penetration values
  3. Unconfined compression strength
  4. Angle of internal friction
  5. Cohesion
  6. "In-Situ" soil density and moisture content
  7. Rock quality designation (RQD) and percent rock sample recovered
  8. Other properties unique to site conditions

 

 

  • The following items should be discussed in the geotechnical report:

 

 

  1. Geological description of site
  2. Observed and expected ground water conditions
  3. Expected frost penetration depth
  4. Corrosion potential of soil and corrosion protection recommendations
  5. Site access and potential construction difficulties
  6. Dewatering or site drainage requirements
  7. Backfill material recommendations
  8. Settlement considerations
  9. Additional information to aid foundation designer
  10. Recommended types of foundations
  11. Design parameters for uplift, download and lateral load
  12. Factor of safety considered when allowable vs. ultimate design parameters are provided
  13. Recommended construction techniques and inspections