Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN 25G Tower...1$7.95
18 inch Telescopic...1$28.40
5' Foot X 1...1$16.30
18 inch Deluxe...1$26.95
53" X 2.00"...1$17.95
EZ19B Roof...2$18.08
3 inch wall...3$12.95
10' Foot X...1$27.95
50 FT RG11...1$35.00
ROHN 25G 10...3$334.00
Complete Grounding...2$32.00
100 FT RG11...1$55.00
Telescopic...10$120.00
ROHN 25G Tower...1$101.00
24 inch Telescopic...1$34.75
4 inch Heavy...1$11.95
10' Foot X...1$28.90
ROHN 4 inch...1$39.00
1/4 inch Heavy...1$1.15
EZ TM-30-U...1$112.00
ROHN 25G 20...1$540.00
3 Foot Tripod...1$31.50
12 inch Deluxe...2$19.95
ROHN 25G Tower...1$205.00
ROHN H40 Telescopi...10$163.00
3 Foot Tripod...1$36.88
8' Foot X 1...1$27.95
ROHN 45G 55G...1$290.00
ROHN 25G 35...1$897.00
ROHN 25AG 45AG...1$49.00
40 Foot Telescopic...1$240.00
ROHN 25G Assembly...1$186.00
Goods Total57$7,058.49
View Cart Check out
Printer View Tell a Friend

ROHN BGK3G Tower Base Ground Kit

Price$92.00
Manufacturer CodeBGK3G
Qty
AvailabilityUsually ships in 24 Hrs
ShippingCan ship Canada

Highlights

(1) 5/8" x 8' Ground Rod
(1) Ground Rod Clamp
(10') of #4 Solid Copper Wire
(1) 5/16 x 2-3/8 G5 HDG Bolt
(1) 5/16 Hex HDG Nut
(1) Hy-Lug YA4C-L4 Compression Terminal Lug

Bulk Quantities Available Here!

 

ROHN BGK3G Tower Base Section Grounding Kit
Primarily for 25G and 45G REV. F Towers with Fixed Bases

 

 

THIS KIT INCLUDES
BGK3G
QUANTITY DESCRIPTION
1 10' of #4 Solid Copper Wire
1 5/8" x 8'  HDG Ground Rod
1 5/8" Ground Rod Clamp
1 5/16" x 2 3/8" Grade 5 HDG Bolt
1 5/16" Hex HDG Nut
1  Hy-Lug YA4C-L4 Compression Terminal Lug 


Comprises enough material to ground at 1 Tower Base Section Joint Bolt. Terminal Lug does NOT come compressed onto the copper wire from the Factory.

 


These are REV. F Tower structure Grounding Kits. The NEW REV. G Tower structure Grounding Kits use wire rope vs. the solid copper found here, in addition to revised clamping methodogies. 

 

This Item Can Ship UPS!

Specification Sheet
grounding type
Grounding Kits
Rate this product.
Product isn't rated yet. Write a review.

Understanding which Grounding Kits to use for what application can be a challenge. Again, REV. F and REV. G play a role in delineating the major differences between the kits and parts supplied with the Complete Tower Packages you purchase. As the approach to Grounding differs between the two, let's first understand which REV.# your Tower may be...

REV. F - All Self-Supporting Towers, all Bracketed Towers and those Guyed Tower Kits with a Part number containing a D between the windspeed and height designations ( ie. R-45G110D040) in the nominclature are REV. F classification and therefore will have these characteristics in common...

REV. F Tower Base Grounding - each Base Grounding Kit will come with material to bond one tower section rail to ground via a clamp, ten foot of solid copper wire and an eight foot ground rod. Depending on the Tower height and Base style, the Tower Kit may contain one, two or three of these Base Grounding Kits. For example; a ten foot Self-Supporting Tower Kit will come with one Base Rail Grounding Kit, the rest will come with two. A Bracketed Tower Kit likewise will come with the same number of Kits depending on Height. A Guyed Tower Kit will come with three of these Kits. A Tower with a Tapered Base Section will come with a Grounding Kit designed to attach via a Lug to one of the side panel plates on the section; rather than a Rail Clamp connection.

REV. F Tower Guy Grounding - each Tower Down Guy Grounding Kit will come with material to bond three Tower Down Guy Anchor locations via a Split Bolt clamp to each Down Guy Stranded Wire with 15 feet of Solid Copper wire to pass through all Split Bolt Bonds on its way to connect with one 8 foot Ground Rod.

REV. G - All Guyed Tower Kits with a a part number containing an R between the windspeed and height designations (ie. R-45G130R040) in the nomenclature are REV. G classification and will have these characteristics in common. The Base and Anchor Grounding Kits model number will end with a "GX"...

REV. G Tower Base Grounding - each Base Grounding Kit will come with material to bond one tower section rail to ground via a clamp, ten foot of solid copper wire and a ten foot ground rod. All Guyed Tower Kits will come with three of these Base Grounding Kits. Those Tower Kits with Tapered Bases will come with hardware to connect to that Base accordingly.

REV. G Tower Guy Grounding - each Tower Down Guy Grounding Kit will come with material to bond three Tower Down Guy Anchor locations via attachment to the Down Guy Anchor Rod itself with a Clamp, 15 feet of Braided Steel Wire Rope to a ten foot Ground Rod.

REV G GROUNDING REQUIREMENT FOR STRUCTURES

Rev G made signicant changes regarding the grounding requirements for structures. A prescriptive approach to grounding was used in Rev F where providing specic grounding leads and ground rods were considered adequate to protect a structure.

Rev G adopted a performance specication approach that requires providing a grounding system that will result in a maximum 10 ohm resistance to earth. Rev G also requires minimum ground lead and ground rod sizes that are greater than the Rev F prescriptive requirements.

Another change is that Rev G does not require specic grounding materials. Rev F required the use of galvanized ground rods with tinned copper leads. Rev G only requires that the leads and connections be compatible with the ground rods from a corrosion standpoint (i.e. minimize di-erence between metals connected).

Rev G does provide default grounding arrangements for various types of structures that are intended to meet the 10 ohm requirement for a wide variety of soil conditions. In accordance with Rev G, the actual resistance of a default grounding system must be veried based on site conditions. Additional ground rods or special grounding systems may be required.

It should be noted that the TIA-222 grounding requirements are meant to protect the structure and foundation from high fault currents. Other grounding requirements are often needed for the protection of antennas, radio equipment and other appurtenances.