Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
Rohn RSL Tower...23$3,710.00
Rohn RSL Tower...21$58.00
50 Foot Telescopic...28$282.00
ROHN RSL TOWER...13$33.00
ROHN 4 inch...25$39.00
Rohn RSL Tower...16$625.00
24 inch Deluxe...32$34.95
Dual Port Coaxial...4$1.65
DS-3000 J Pipe...3$28.95
ROHN 8 inch...8$79.00
Rohn RSL Tower...13$60.50
ROHN 25G Top...4$298.00
HOLLAND LA...7$11.95
EZ32A Telescopic...25$21.95
ROHN 45G 40...2$1,605.00
ROHN 45G Tower...3$240.00
ROHN TUF TUG...15$335.00
40 Foot Telescopic...1$240.00
18 inch Telescopic...30$28.40
EZ32 Telescopic...19$14.95
Telescopic...125$164.00
Rohn RSL Tower...22$156.00
Rohn RSL Tower...18$372.00
MOBILE/RACKMOUNT...1$199.00
5' Foot X 1...29$16.30
HOLLAND 12...2$2.65
ROHN 24 inch...22$88.00
4 inch Heavy...23$11.95
3 inch wall...5$12.95
Holland HPF...2$2.45
ROHN 55G Top...2$425.00
Turnbuckle...4$3.05
BNC Male to...5$1.55
ROHN RSL 100...24$6,636.00
ROHN 25G 30...2$694.00
ROHN Tower...7$38.00
50 FT RG11...14$35.00
Rohn RSL RGKG...21$430.00
ROHN 45G Tower...1$425.00
30 inch Telescopic...21$24.95
Rohn RSL Tower...18$592.00
3S60 620 Plastic...2$108.00
12 inch Telescopic...24$23.50
HOLLAND 6 dB...5$2.65
3 dB Power...4$3.65
Complete Grounding...19$32.00
ROHN 65G 60...1$7,150.00
75 FT RG11...11$45.00
ROHN BGK2G...3$89.00
Concrete Base...2$14.95
RG6 RG59 RG58...2$8.95
Push on F Connector...3$0.79
100 FT RG11...10$55.00
21" J Pipe...1$19.95
ROHN Lightning...2$69.00
ROHN 18 inch...26$86.00
TTRSL100 Safety...17$850.00
ROHN 45G 55G...3$290.00
Tower Side...1$139.95
LNS5010 Black...3$39.95
2 inch W type...2$10.95
50 Foot Telescopic...26$325.00
Rohn RSL Tower...18$345.00
Rohn RSL Tower...15$1,540.00
53" X 2.00"...10$17.95
HOLLAND 2-Way...4$2.60
ROHN 25G 10...1$334.00
ROHN TUF TUG...1$325.00
125 FT RG11...14$59.00
ROHN 12 inch...25$84.00
ROHN 25G 35...2$897.00
ROHN 65G 20...1$2,600.00
ROHN 25G Accessory...3$74.00
Non-Penetrating...6$24.95
EZ32C Telescopic...17$24.95
RG6 Twist-on...1$0.19
Thomas and...1$4.90
Cat6 UTP 550...2$9.00
ROHN H50 Telescopi...125$189.00
Rohn RSL Tower...18$1,345.00
BNC Male to...1$2.25
Rohn RSL Tower...20$1,150.00
PPC EX6 PLUS...3$0.24
Thomas & Betts...1$6.65
ROHN 65G 20...2$3,582.00
Rohn Universal...3$49.00
#12 Solid Copper...2$24.95
ROHN RSL 100...22$6,090.00
1/8" Down...3$0.95
ROHN Bolt Kit...5$7.50
ROHN 55G Tower...2$298.00
DC Voltage...7$1.95
ROHN 45G 35...1$1,715.00
PPC AquaTight...3$2.95
Thomas & Betts...1$0.36
EZ TM-50-U...25$164.00
RASK12 Accessory...20$296.00
PLA1000 F Connecto...4$49.95
225 FT RG11...17$99.00
Rohn RSWGB...16$260.00
ROHN 45G 20...2$915.00
Rohn RSL Tower...15$310.00
BNC Female...1$2.25
EZ46-3 Pitch...3$3.95
4 inch W type...3$10.95
HOLLAND LA...1$14.95
ROHN 55G Tower...2$420.00
57" Inch X...1$18.95
ROHN Lightning...20$145.00
Holland G-F81F*...4$0.39
ROHN 25G Tower...1$335.00
EZ TM-30-U...2$112.00
Holland TSTL...1$24.95
ROHN 25G Tower...6$97.00
ROHN 25G Tower...2$260.00
ROHN RSL 100...1$6,400.00
Portable 3...3$27.95
CAT6 Plenum...1$310.50
ROHN Universal...12$70.38
FAM-12HR 12...25$2.45
ROHN 25G Tower...2$289.00
ROHN 25G Tower...1$310.00
ROHN 45AG Tower...1$14.95
Commscope RG11...1$230.00
30 Foot Telescopic...2$206.00
ROHN 65G 30...2$3,406.00
Dual Side Arm...1$159.95
3/4 Inch Ground...1$3.80
8' Foot X 1...2$27.00
ROHN 65G Adjustabl...3$745.00
Rohn RSL Tower...20$196.00
In-Line Power...1$28.95
5 Foot Heavy...1$79.95
ROHN RSL 90...1$6,140.00
3/8 X 4 Foot...1$16.00
EZ19B Roof...5$18.08
ROHN NPPK Non...5$469.95
EZ48 48" Single...3$32.95
ROHN Universal...5$695.00
ROHN 65g Top...1$319.95
ROHNJACK G...4$329.00
27 dB 1 GHz...2$2.65
24 dB 2 Port...1$2.89
RG6 Underground...2$70.00
RG11 RG7 RG6...5$12.95
RG11 RG7 RG6...2$24.95
30 Foot Telescopic...1$166.00
12 dB 2 Port...1$2.89
Six Port Keystone...2$1.05
36 Inch Roof...2$49.00
3/8TBE&J Turnbuckl...1$10.95
ROHN 55G 40...2$2,005.00
BNC Male to...2$1.90
PL-259 Teflon...1$2.25
RG6 Underground...3$68.00
PPC AquaTight...1$2.20
75 Ohm F Port...75$0.45
PPC EX6XL PLUS...3$0.26
TFC RG11-OR...1$225.00
EZ30 30" Single...3$17.95
RG6 Underground...1$38.00
HDMI v1.4 High...1$59.95
ROHN R-CPC1/1...1$37.00
3S-SCX4 Crossover...1$15.95
Non-Penetrating...4$131.00
ROHN 25G 40...1$1,639.00
ROHN 65G 10...1$1,908.00
LNS5000 Big...2$67.95
Protective...1$24.95
EZ DM 166-2...3$22.00
30 dB 1 GHz...1$2.65
ROHN 25G Anti...3$598.00
ROHN 25G 10...3$156.00
Thomas & Betts...1$1.50
ROHN 25G Tower...1$7.95
5' Foot X 1...7$16.00
Gripple 1/8"...1$6.25
20 Foot Telescopic...2$126.00
ROHN 65G 40...1$5,090.00
UHF Female...1$4.89
HOLLAND 2-Way...3$2.60
618 Telescopic...3$134.00
8 inch Deluxe...2$16.95
ROHN 25G Tower...4$101.00
Telescopic...10$120.00
BNC Male to...1$3.00
ROHN 55G Tower...1$1,350.00
2 Inch Top...1$48.00
TTRSL50 Safety...1$580.00
Dual Port Coaxial...2$1.35
60 Inch Roof...1$73.00
Galvanized...1$6.45
Aluminum Mast...1$71.00
ROHN 65G 10...1$1,250.00
ROHN Universal...1$595.00
ROHN 45G 10...2$570.00
ROHN 65G 20...1$1,668.00
EZ46-3PO Pitch...5$1.90
ROHN Protective...1$450.00
ROHN 25G 40...2$865.00
Digital Broadband...1$29.95
ROHN H20 Telescopi...10$75.00
Coaxial Cable...1$1.95
U-Bolt Kit...1$6.95
1/4" Down...1$1.20
MCR 4-Way Horizont...1$4.60
ROHN 25G Adjustabl...1$186.00
RG6 Underground...1$62.00
ROHN 65G 10...2$1,695.00
ROHN Leg Mounted...2$165.00
Thomas & Betts...1$1.30
ROHN 25G Adjustabl...2$203.00
9 dB 2 Port...1$2.89
5/16 inch Heavy...1$1.65
Channel Master...1$1.40
Non-Penetrating...1$115.00
ROHN H40 Telescopi...5$163.00
Holland F-811...1$0.15
4 inch W type...1$10.95
F-81 Coupler...1$1.05
40 Foot Telescopic...2$309.00
ASKA 4-Way...1$4.60
20 dB 2 Port...1$2.89
Aluminum Mast...1$54.00
ROHN RTL 150...1$0.00
ROHN 25G 45G...1$210.00
Telescopic...10$117.00
ROHN GAS625...2$79.95
PPC EX6WS AquaTigh...3$0.28
ROHN Bolt Kit...1$14.95
20 Foot Telescopic...3$158.00
LNS5082 RG6...1$27.95
4 inch TV Antenna...1$12.00
ROHN 45G/55G...1$558.00
ROHN 6 inch...2$39.00
ROHN 45G Self...1$595.00
ROHN 25AG 45AG...1$49.00
EZ60 620 Plastic...2$7.95
Heavy Duty...1$18.95
RG6 Coaxial...1$19.95
ROHN 65G Tower...2$780.00
ROHN 55G Torque...1$250.00
EZ60A 620 Steel...1$82.95
1 HDMI + 2...1$16.00
APICA AP-BNC...1$1.50
ROHN 25G 45G...1$316.00
ROHN 25G Antenna...2$415.00
ROHN 25G 45G...2$318.00
ROHN 65G Tower...1$665.00
ROHN Heavy...1$468.00
10' Foot X...1$28.90
HOLLAND 20...3$2.65
ROHN 25G Thrust...1$78.00
1/4 inch Heavy...1$1.15
ROHN 25G Tower...1$79.00
ASKA 2-Way...1$1.60
ROHN 25G Tower...1$398.00
24 inch Telescopic...2$34.75
ROHN 25G Assembly...1$186.00
HOLLAND HFS...1$2.50
ROHN D1130...1$379.00
500 FT RG11...1$134.95
30 dB 2 Port...1$2.89
ROHN 25G Tower...2$358.00
ROHN 55G Tower...1$332.00
ROHN 45G 55G...1$745.00
12 inch Deluxe...1$19.95
FAM-8HR 8 dB...1$2.75
ROHN 45G Tower...1$1,100.00
Broadband Digital...1$26.95
Thomas and...1$0.35
8' Foot X 1...1$27.95
ROHN 25G 70...1$2,130.00
ROHN 25G Tower...1$290.00
EZ DM 166-2...1$17.95
MM2 Universal...1$13.95
EZ TM-20-U...1$83.00
Dual Port Coaxial...1$1.30
Goods Total1727$740,954.07
View Cart Check out
Printer View Tell a Friend

4C/14 AWG SOLID FPLP SHIELDED PLENUM- RED - 1000 FT

Price$650.00
Manufacturer Code14/4FPLP-SH
Qty
AvailabilityUsually ships in 24 Hrs

Highlights

- 1000 ft
- 14/4FPLR
- Solid
- Shielded
- Plenum

Bulk Quantities Available Here!

14/4FPLP-SH 4C/14 AWG SOLID FPLP SHIELDED PLENUM - RED - 1000 FT

Power limited fire alarm and communications cable for Riser and Non-Riser applications. Fire Alarm, Fire Protective Circuits, Smoke Detectors, Monitor/Detection, Signal, Control Circuits, Initiating Circuits, and Notification Circuits.

Features:
Multi-Conductor Shielded FPLP- Low smoke PVC insulated solid bare copper conductors, twisted with an overall AL shield and low smoke PVC jacket. Ripcord and sequential foot markings printed on jacket.

Construction Details:
Total Number Conductors: 4
Awg: 14
Stranding: Solid Strand
Conductor Material: Bare copper
Insulation Material: Low smoke copolymer
Insulation Thickness: .010”
Nominal Insulation Diameter: .084”
Drain wire: 24 awg solid tinned copper
Tape Material: Low Smoke Aluminum/Mylar Foil
Nominal Cabling Diameter: .172”
Final Jacket Material: Low smoke copolymer
Nominal Thickness: .018”
Jacket Color: Red
Nominal Jacket Diameter: .208”
Ripcord: Yes

Rate this product.
Product isn't rated yet. Write a review.

NEC Article 760:

NEC Article 760 covers the installation of wiring and equipment of fire alarm systems, including all circuits controlled and powered by the fire alarm system.These systems are defined in the NEC as "The portion of the wiring system between the load side of the overcurrent devices or the power-limited supply and the connected equipment of all circuits powered and controlled by the fire alarm system."


POWER-LIMITED FIRE ALARM SYSTEM CABLES:

1.Type FPL- FPL power-limited fire alarm cable is listed by the NEC as being suitable for general purpose fire alarm use. This listing excludes installation in riser, ducts, plenums and other spaceused for environmental air unless the cable is installed in conduit. All FPL cables are listed as being resistant to the spread of fire and must pass both UL test 1424 and the vertical flame test UL 1581.

2.Type FPLR- FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling from floor to floor. Riser cables must pass both UL test 1424 and the Vertical riser test UL 1666.

3.Type FPLP- FPLP power-limited fire alarm cable is listed by the NEC as being suitable for usein ducts, plenums and other space used for environmental air. All FPLP cable are listed as having adequate fire resistant and low-smoke producing characteristics and must pass both UL test 1424 and UL Stiener tunnel test 910. (NFPA262)

o No Voltage Rating Markings on PLFA Cables

o CL3 and CM rated cables, which have a voltage rating of 300V are permitted to be used as PLFA cables.

o Power-limited is inherently limited by the power supply

o Transformer

o Other Power Supply Devices


NON POWER-LIMITED FIRE ALARM SYSTEM CABLES:

1.Type NPLF- NPLF Non power-limited fire alarm cable is listed by the NEC as being suitable for general purpose fire alarm use. This listing excludes installation in riser, ducts, plenums and other space used for environmental air unless the cable is installed in conduit. All NFPL cables are listed as being resistant to the spread of fire and must pass both UL test 1424 and the vertical flame test UL 1581.

2.Type NPLFP- NPLFP Non power-limited fire alarm cable is listed by the NEC as being suitable for use in ducts, plenums and other space used for environmental air. All NPLFP cable are listed as having adequate fire resistant and low-smoke producing characteristics and must pass both UL test 1424 and UL Stiener tunnel test 910.(NFPA262)

o Power source of NPLFA circuits output voltage shall not exceed 600 volts Nominal

o Marking on NPLF cables are not addressed as 150V. For use in 150V or less on NPLF circuits (out of tray or conduit)

o Class 1 cables can be installed and used as NPLFA, but must be placed in a tray or conduit.

o Overcurrent devices shall be located at the point where the device to be protected receives its supply.


CONVENTIONAL ( STANDARD) FIRE ALARM SYSTEM

Conventional Fire Alarm Systems, in their various forms, have been around for many of years and have changed little in that time in terms of technology although design and reliability have impoved significantly. However, Conventional systems are a well proven technology protecting many hundreds of thousands of properties worldwide. A Conventional Fire Alarm System is often the natural choice for smaller systems or where budget constraints exist. In a Conventional Fire Alarm System the "Intelligence" of the system resides solely within the Fire Alarm Control Panel. The panel receives a trigger signal from a Conventional Detector or Initiating Device Circuit (Smoke, heat, flame detectors) which in turn signals the condition to the Notification (Indicating) Device Circuit such as alarm sounders, horns, strobes and other remote signalling equipment. Conventional detectors are normally connected to the Fire Control Panel via dedicated circuits, each circuit protecting a designated "Zone"or area of the building. The system has different modes: Normal, Alarm, Trouble, and others, depending on the Fire Alarm Manufacturer.

 

CONVENTIONAL FIRE ALARM CABLE SELECTION

The designer must be sure that the last device on the circuit has sufficient voltage to operate the device within its rated voltage. When calculating the voltage available to the last device, it is necessary to consider the voltage drop due to the resistance of the wire. The larger the wire, the less the voltage drop. Generally, for purposes of determining the wire size necessary for the system, it is best to consider all of the devices as "lumped"on the end of the supply circuit, this simulates the worst case.

Typical wire size resistance: Loop Resistance

18 AWG solid: Approximately 6.5ohms/1000ft. 13ohms/1000ft.

16 AWG solid: Approximately 4.1ohms/1000ft. 8.2ohms/1000ft.

14 AWG solid: Approximately 2.6ohms/1000ft. 5.2ohms/1000ft.

12 AWG solid: Approximately 1.8ohms/1000ft. 3.6ohms/1000ft.