Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN Universal...1$595.00
75 FT RG11...12$45.00
12 inch Telescopic...24$23.50
ROHN 25G 35...1$897.00
EZ19A Roof...2$12.85
Telescopic...5$144.00
ROHN 65G Tower...1$665.00
ROHN 12 inch...14$84.00
Complete Grounding...17$32.00
ROHN Bolt Kit...2$7.50
ROHN 25G 45G...3$318.00
50 Foot Telescopic...8$325.00
ROHN 55G Top...1$425.00
30 inch Telescopic...18$24.95
ROHN 4 inch...10$39.00
BNC Male to...1$3.00
Thomas & Betts...1$0.36
4 inch Heavy...16$11.95
24 inch Telescopic...4$34.75
ROHN 55G Assembly...1$357.00
EZ19B Roof...8$18.08
ROHN Lightning...10$145.00
40 Foot Telescopic...1$309.00
ROHN 65G Adjustabl...2$745.00
EZ46-3PO Pitch...5$1.90
Hinged Wall...1$20.00
ROHN H20 Telescopi...5$75.00
BNC Male to...1$4.95
Rohn RSL Tower...12$372.00
EZ32C Telescopic...9$24.95
ROHN 45G 20...1$915.00
Rohn RSL Tower...12$625.00
Rohn RSL Tower...17$592.00
5' Foot X 1...17$16.30
50 Foot Telescopic...14$282.00
RASK12 Accessory...8$296.00
Rohn RSL RGKG...12$430.00
53" X 2.00"...3$17.95
50 FT RG11...12$35.00
EZ32 Telescopic...14$14.95
ROHN BGK2G...1$89.00
Rohn RSL Tower...14$345.00
EZ32A Telescopic...21$21.95
Heavy Duty...2$24.95
ROHN 45G Self...1$595.00
Telescopic...80$164.00
Rohn RSL Tower...11$1,345.00
ROHN Universal...17$70.38
Tower Side...1$139.95
ROHN 25G Tower...2$335.00
ROHN TUF TUG...14$335.00
Rohn RSL Tower...8$196.00
TTRSL100 Safety...12$850.00
ROHN H50 Telescopi...45$189.00
Rohn RSL Tower...19$1,150.00
4 inch W type...3$10.95
18 inch Telescopic...18$28.40
ROHN 45G 40...4$1,605.00
ROHN 25G Antenna...2$415.00
ROHN 8 inch...14$79.00
#12 Solid Copper...3$24.95
Rohn RSL Tower...15$58.00
EZ TM-50-U...18$164.00
Rohn RSL Tower...13$3,710.00
ROHN TUF TUG...1$325.00
Channel Master...1$1.40
LNS5082 RG6...2$27.95
HOLLAND 9 dB...2$2.65
ROHN RSL 100...8$6,090.00
Rohn RSL Tower...10$310.00
Rohn RSL Tower...9$156.00
125 FT RG11...13$59.00
EZ TS-50 Free...2$69.95
Aluminum Mast...1$68.00
ROHN RSL TOWER...5$33.00
DS-3000 J Pipe...3$28.95
ROHN 45G 55G...2$745.00
ROHN 12 inch...1$45.00
1/8" Down...1$0.95
ROHN 25G Tower...1$310.00
Rohn RSL Tower...8$1,540.00
3 inch wall...5$12.95
CAT6 Plenum...1$310.50
Rohn RSL Tower...6$60.50
HOLLAND 16...2$2.65
ROHN 25G Tower...1$358.00
RG6 Underground...1$70.00
Gripple Tensioning...1$87.00
FAM-12HR 12...25$2.45
36 Inch Roof...2$49.00
ROHN Tower...1$38.00
ROHN 18 inch...12$86.00
ROHN 24 inch...1$48.00
ROHN 25G 10...3$156.00
Dual Port Coaxial...1$1.35
Thomas and...2$0.35
Mastic Sealing...2$1.95
PPC EX6WS AquaTigh...2$0.28
100 FT RG11...4$55.00
RG6 Coaxial...1$12.95
In-Line Cable...1$32.95
8 inch Deluxe...1$16.95
ROHN 65G Section...2$84.95
ROHN 65G 20...2$3,582.00
ROHN 55G Tower...3$298.00
Heavy Duty...1$16.95
RG6 Underground...2$38.00
ROHN 25G Accessory...2$74.00
ROHN RSL 100...8$6,636.00
HOLLAND HDA...1$189.95
ROHN 25G 40...2$865.00
ROHN 24 inch...17$88.00
Concrete Base...1$14.95
Rohn RSWGB...7$260.00
225 FT RG11...5$99.00
ROHN 65G Tower...1$1,350.00
ROHN 8 inch...1$47.00
3 dB Power...2$3.65
PLA1000 F Connecto...2$49.95
20 Foot Telescopic...1$126.00
ROHN 65G 35...1$4,836.00
EZ TM-50-5U...2$115.00
RJ45 8P8C Plug...1$21.95
ROHN Bolt Kit...3$14.95
4 inch TV Antenna...2$12.00
ROHN 25G 45G...2$210.00
Holland Electronic...1$2.95
"Y" Style Chimney...1$35.90
EZ60A 620 Steel...3$82.95
ROHN 65G Anti...1$960.00
3 Foot Tripod...2$31.50
Holland Electronic...1$2.95
ROHN NPPK Non...2$469.95
Protective...1$24.95
12 dB 2 Port...2$2.89
Telescopic...20$117.00
3S60 620 Plastic...1$108.00
Rohn RSL Tower...1$186.00
24 inch Deluxe...8$34.95
ROHN Tower...1$63.00
ROHN 25G Tower...2$168.00
Telescopic...5$120.00
ROHN 45G 10...1$570.00
HOLLAND 8-Way...1$9.95
5/8 X 8 Foot...1$16.95
ROHN 65G Tower...1$425.00
Thomas & Betts...1$14.95
ROHN 25G Tower...2$79.00
Dual Port Coaxial...3$1.65
ROHN 65G Tower...1$734.00
ROHN 25G Tower...1$7.95
10 Foot Standard...1$275.00
RG6 Coaxial...1$6.95
ROHN 25G Top...1$264.00
ROHN 55G Tower...2$1,350.00
3 Foot Tripod...1$28.60
ROHN GAS604...2$69.95
ROHN 25G Tower...1$260.00
ROHN 18 inch...1$47.00
ROHN 45G 45...3$2,150.00
Holland TSTL...2$24.95
ROHN 25G Top...1$298.00
Broadband Digital...3$26.95
Non-Penetrating...2$131.00
ROHN 45G Tower...1$430.00
Six Port Keystone...2$1.05
Aluminum Mast...2$54.00
ROHN 25G Adjustabl...1$203.00
10' Foot X...1$27.95
Non-Penetrating...1$115.00
18 inch Deluxe...1$26.95
ROHN 25G Tower...1$97.00
ROHN 25G Tower...1$101.00
ROHN 65G 45...1$6,253.00
RG6 Twist-on...2$0.19
ROHN 25G Adjustabl...1$186.00
Single Port...1$0.95
20 dB 2 Port...1$2.89
9 dB 2 Port...1$2.89
8' Foot X 1...2$27.00
EZ46-3 Pitch...1$3.95
75 Ohm F Port...25$0.45
HOLLAND HFS...1$2.25
Non-Penetrating...3$24.95
2 Inch Top...1$48.00
ROHN 25G 45G...1$316.00
ROHN H40 Telescopi...5$163.00
30 Foot Telescopic...1$166.00
F Male to RCA...1$1.10
APICA AP-RCA...1$1.39
ROHN 25G Assembly...1$186.00
ROHN Universal...1$695.00
HOLLAND HFS...1$2.50
EZ48 48" Single...1$32.95
6 inch TV Antenna...1$10.82
DC Voltage...1$1.95
ROHN 25G Tower...1$290.00
Aluminum Mast...1$71.00
12 inch Deluxe...1$19.95
Push on F Connector...1$0.79
ROHN 25G Tower...1$110.00
RG6 Coaxial...1$3.95
ROHN 65g Top...1$319.95
Heavy Duty...1$9.95
RG11 RG7 RG6...1$24.95
27 dB 2 Port...1$2.89
Goods Total1021$371,085.00
View Cart Check out
Printer View Tell a Friend

4C/18 AWG SOLID FPLR PVC- RED - 1000 FT

Price$248.40
Manufacturer Code18/4FPLR
Qty
AvailabilityUsually ships in 24 Hrs

Highlights

- 1000 ft
- 18/4FPLR
- Solid
- Non-Shielded

Bulk Quantities Available Here!

18/4FPLR 4C/18 AWG SOLID FPLR PVC - RED - 1000 FT

Power limited fire alarm and communications cable for Riser and Non-Riser applications. Fire Alarm, Fire Protective Circuits, Smoke Detectors, Monitor/Detection, Signal, Control Circuits, Initiating Circuits, and Notification Circuits.

Features:
Multi-Conductor Unshielded FPLR- Insulated solid bare copper conductors, twisted with a sunlight resistant PVC jacket. Ripcord and sequential foot markings printed on jacket.

ETL FPLR or CL2R, NEC Article 760, California State Fire Marshall.

Construction Details:
Total Number Conductors: 4
Awg: 18
Stranding: Solid Strand
Conductor Material: Bare Copper
Insulation Material: PVC
Insulation/Dielectric Thickness: .008”
Nominal Insulation Diameter: .056”
Nylon: N/A
Nylon Thickness: N/A
Nominal Operation Diameter: N/A
Cabling pairs: N/A
Drain wire: N/A
Cabling Overall Lay: 2 1/4” left hand lay
Fillers: N/A
Tape Material: N/A
Drain Wire Material: 7 Strand 22 AWG Tinned Copper
Nominal Cabling Diameter: .112”
Copper tape: N/A
Final Jacket Material: PVC
Nominal Thickness: .015”
Jacket Color: Red
Nominal Jacket Diameter: .142”
Ripcord: Yes
Steel Messenger: N/A

Rate this product.
Product isn't rated yet. Write a review.

NEC Article 760:

NEC Article 760 covers the installation of wiring and equipment of fire alarm systems, including all circuits controlled and powered by the fire alarm system.These systems are defined in the NEC as "The portion of the wiring system between the load side of the overcurrent devices or the power-limited supply and the connected equipment of all circuits powered and controlled by the fire alarm system."


POWER-LIMITED FIRE ALARM SYSTEM CABLES:

1.Type FPL- FPL power-limited fire alarm cable is listed by the NEC as being suitable for general purpose fire alarm use. This listing excludes installation in riser, ducts, plenums and other spaceused for environmental air unless the cable is installed in conduit. All FPL cables are listed as being resistant to the spread of fire and must pass both UL test 1424 and the vertical flame test UL 1581.

2.Type FPLR- FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling from floor to floor. Riser cables must pass both UL test 1424 and the Vertical riser test UL 1666.

3.Type FPLP- FPLP power-limited fire alarm cable is listed by the NEC as being suitable for usein ducts, plenums and other space used for environmental air. All FPLP cable are listed as having adequate fire resistant and low-smoke producing characteristics and must pass both UL test 1424 and UL Stiener tunnel test 910. (NFPA262)

o No Voltage Rating Markings on PLFA Cables

o CL3 and CM rated cables, which have a voltage rating of 300V are permitted to be used as PLFA cables.

o Power-limited is inherently limited by the power supply

o Transformer

o Other Power Supply Devices


NON POWER-LIMITED FIRE ALARM SYSTEM CABLES:

1.Type NPLF- NPLF Non power-limited fire alarm cable is listed by the NEC as being suitable for general purpose fire alarm use. This listing excludes installation in riser, ducts, plenums and other space used for environmental air unless the cable is installed in conduit. All NFPL cables are listed as being resistant to the spread of fire and must pass both UL test 1424 and the vertical flame test UL 1581.

2.Type NPLFP- NPLFP Non power-limited fire alarm cable is listed by the NEC as being suitable for use in ducts, plenums and other space used for environmental air. All NPLFP cable are listed as having adequate fire resistant and low-smoke producing characteristics and must pass both UL test 1424 and UL Stiener tunnel test 910.(NFPA262)

o Power source of NPLFA circuits output voltage shall not exceed 600 volts Nominal

o Marking on NPLF cables are not addressed as 150V. For use in 150V or less on NPLF circuits (out of tray or conduit)

o Class 1 cables can be installed and used as NPLFA, but must be placed in a tray or conduit.

o Overcurrent devices shall be located at the point where the device to be protected receives its supply.


CONVENTIONAL ( STANDARD) FIRE ALARM SYSTEM

Conventional Fire Alarm Systems, in their various forms, have been around for many of years and have changed little in that time in terms of technology although design and reliability have impoved significantly. However, Conventional systems are a well proven technology protecting many hundreds of thousands of properties worldwide. A Conventional Fire Alarm System is often the natural choice for smaller systems or where budget constraints exist. In a Conventional Fire Alarm System the "Intelligence" of the system resides solely within the Fire Alarm Control Panel. The panel receives a trigger signal from a Conventional Detector or Initiating Device Circuit (Smoke, heat, flame detectors) which in turn signals the condition to the Notification (Indicating) Device Circuit such as alarm sounders, horns, strobes and other remote signalling equipment. Conventional detectors are normally connected to the Fire Control Panel via dedicated circuits, each circuit protecting a designated "Zone"or area of the building. The system has different modes: Normal, Alarm, Trouble, and others, depending on the Fire Alarm Manufacturer.

 

CONVENTIONAL FIRE ALARM CABLE SELECTION

The designer must be sure that the last device on the circuit has sufficient voltage to operate the device within its rated voltage. When calculating the voltage available to the last device, it is necessary to consider the voltage drop due to the resistance of the wire. The larger the wire, the less the voltage drop. Generally, for purposes of determining the wire size necessary for the system, it is best to consider all of the devices as "lumped"on the end of the supply circuit, this simulates the worst case.

Typical wire size resistance: Loop Resistance

18 AWG solid: Approximately 6.5ohms/1000ft. 13ohms/1000ft.

16 AWG solid: Approximately 4.1ohms/1000ft. 8.2ohms/1000ft.

14 AWG solid: Approximately 2.6ohms/1000ft. 5.2ohms/1000ft.

12 AWG solid: Approximately 1.8ohms/1000ft. 3.6ohms/1000ft.