Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
In-Line Cable...1$32.95
20 dB 2 Port...1$2.89
50 FT RG11...8$35.00
ROHN 25G Tower...1$7.95
18 inch Telescopic...19$28.40
12 inch Telescopic...14$23.50
F-81 Coupler...1$1.05
125 FT RG11...5$59.00
Rohn Universal...2$49.00
1 HDMI + 3...1$18.00
Telescopic...10$120.00
4 inch W type...1$10.95
ROHN 25G Tower...1$836.00
Telescopic...10$144.00
RG11 Quad Shield...1$185.00
ROHNJACK G...4$329.00
30 inch Telescopic...10$24.95
2.5" to 3.75"...1$14.50
ROHN 65g Top...2$319.95
40 Foot Telescopic...1$240.00
Dual Port Coaxial...2$1.30
5/8 inch Round...1$14.95
ROHN 25G Accessory...3$74.00
ROHN 25G Replaceme...1$32.95
ROHN 25G Tower...2$369.00
ROHN 25G Side...1$43.00
225 FT RG11...17$99.00
ROHN 25G Universal...1$128.00
TFC RG11-OR...1$225.00
ROHN 24 inch...17$88.00
ROHN RSL 90...1$6,325.00
ROHN 18 inch...11$86.00
RG6 Coaxial...1$3.95
ROHN 25G 20...1$540.00
ROHN 25G 40...1$865.00
Complete Grounding...19$32.00
QCE 4-Way Horizont...1$3.60
ROHN 25G Tower...1$79.00
30 Foot Telescopic...2$206.00
ROHN 25G Top...2$264.00
ROHN 45GSR...1$640.00
Non-Penetrating...1$17.00
ROHN 25AG 45AG...3$49.00
BNC Male to...1$2.25
ROHN 45G Top...1$398.00
12 inch Deluxe...2$19.95
ROHN 45G Tower...3$204.00
ROHN 25G 30...1$694.00
EVO1-SP-4 Cable...1$3.60
ROHN RSL 100...11$6,090.00
24 inch Deluxe...15$34.95
Rohn RSL Tower...14$1,150.00
Rohn RSL RGKG...12$430.00
HOLLAND HDA...3$189.95
ROHN Universal...12$70.38
Telescopic...40$164.00
HOLLAND HFS...3$2.50
Rohn RSL Tower...8$1,345.00
PPC Single...1$1.25
Rohn RSL Tower...7$156.00
ROHN TUF TUG...7$335.00
Rohn RSL Tower...7$3,710.00
ROHN 4 inch...15$39.00
Turnbuckle...2$3.05
4 inch Heavy...21$11.95
EZ TM-50-U...7$164.00
Dual Port Coaxial...2$1.35
EZ TM-40-U...1$139.95
5' Foot X 1...13$16.30
ROHN 25G Tower...1$335.00
ROHN 65G Tower...1$1,350.00
ROHN Tower...5$38.00
ROHN RSL 100...11$6,636.00
3 inch wall...2$12.95
ROHN 25G 90...1$2,475.00
EZ32A Telescopic...12$21.95
Rohn RSL Tower...16$1,540.00
HOLLAND 2-Way...3$2.60
ROHN Bolt Kit...1$14.95
50 Foot Telescopic...17$325.00
Rohn RSWGB...5$260.00
RASK12 Accessory...5$296.00
618 Telescopic...1$134.00
RG6 Coaxial...1$69.95
ROHN TUF TUG...1$325.00
EZ19B Roof...8$18.08
Rohn RSL Tower...9$372.00
ROHN 12 inch...10$84.00
EZ32C Telescopic...9$24.95
30 dB 1 GHz...1$2.65
EZ46-3PO Pitch...3$1.90
30 Foot Telescopic...3$166.00
Rohn RSL Tower...11$345.00
Rohn RSL Tower...7$625.00
PPC AquaTight...1$2.95
3/8 X 4 Foot...1$16.00
ROHN H50 Telescopi...85$189.00
Dual Side Arm...1$159.95
EZ46-3 Pitch...5$3.95
ROHN 25G 10...1$156.00
30 dB 2 Port...1$2.89
ROHN Bolt Kit...3$7.50
ROHN 55G Tower...1$332.00
50 Foot Telescopic...10$282.00
Adjustable...1$8.95
ROHN 8 inch...8$79.00
Rohn RSL Tower...15$592.00
PPC EX6WS AquaTigh...2$0.28
PLA1000 F Connecto...1$49.95
ROHN 65G Tower...1$390.00
RG6 RG59 RG58...1$8.95
Dual Port Coaxial...1$1.65
100 FT RG11...5$55.00
ROHN 25G Antenna...1$415.00
ROHN RSL TOWER...6$33.00
ROHN 18 inch...1$47.00
EZ32 Telescopic...11$14.95
Rohn RSL Tower...5$58.00
ROHN 12 inch...2$45.00
53" X 2.00"...3$17.95
RG6 Coaxial...1$6.95
Rohn RSL Tower...6$60.50
Protective...3$24.95
TTRSL50 Safety...1$580.00
TTRSL100 Safety...14$850.00
ROHN 65G Tower...1$780.00
Non-Penetrating...2$24.95
ROHN 25G 35...1$897.00
EZ60A 620 Steel...1$82.95
ROHN Lightning...7$145.00
ROHN 65G 10...2$1,695.00
EZ DM 166-2...2$22.00
Telescopic...10$117.00
Rohn RSL Tower...7$310.00
ROHN 55G Tower...1$778.50
Rohn RSL Tower...4$196.00
Gripple Tensioning...1$87.00
Heavy Duty...1$9.95
RG6 Underground...2$38.00
RG11 RG7 RG6...3$24.95
Single Port...2$0.95
ROHN 25G Top...1$298.00
PPC EX6XL PLUS...1$0.26
ROHN 45G Tower...1$430.00
75 FT RG11...5$45.00
24 inch Telescopic...2$34.75
3 Foot Tripod...1$36.88
Cat6 UTP 550...1$16.95
5/8TBE&J Turnbuckl...1$19.95
2 inch W type...3$10.95
Thomas and...1$0.35
10' Foot X...1$27.00
Holland TSTL...1$24.95
1 HDMI + 1...1$13.00
ROHN 25G 100...1$2,585.00
ROHN 65G 40...2$5,090.00
EZ TS-50 Free...4$69.95
BNC Female...1$2.25
3/8TBE&J Turnbuckl...3$10.95
Holland HPF...2$2.45
ROHN 55G Tower...2$298.00
GLASS SHELF...1$46.00
RG6 Underground...1$68.00
BNC Male to...1$1.90
7 Inch Cable...1$2.50
42U Empty Equipmen...1$930.00
ROHN 65G 20...2$2,600.00
ROHN 45G 55G...1$290.00
PPC EX6 PLUS...2$0.24
ROHN 65G 20...1$3,582.00
EZ TM-30-U...1$112.00
Push on F Connector...1$0.79
24 dB 1 GHz...1$2.65
Thomas and...2$4.90
Non-Penetrating...1$115.00
4 inch TV Antenna...1$12.00
ROHN 25G 45G...1$210.00
3 Foot Tripod...1$28.60
ROHN 55G 30...1$1,820.00
U-Bolt Kit...1$6.95
57" Inch X...2$18.95
LNS5000 Big...1$67.95
Mastic Sealing...1$1.95
1/4 inch Heavy...2$1.15
ROHN 45G 30...1$1,260.00
Aluminum Mast...1$84.00
ROHN 45AG Tower...1$14.95
ROHN 25G Tower...1$97.00
ROHN 45G/55G...1$558.00
5/8 X 10 Foot...1$28.95
3/16" Extra...1$359.95
ROHN 25G 40...1$1,639.00
Thomas & Betts...1$1.30
3/8" Protective...1$68.00
ROHN 25G 45G...1$318.00
1/4" Extra...1$239.00
45G Main Straight...1$13.95
BNC Male to...1$1.55
ROHN Universal...1$695.00
ROHN 45G Self...1$595.00
ROHN 65G Adjustabl...1$745.00
75 Ohm F Port...25$0.45
ROHN 65G 10...1$1,250.00
LNS5010 Black...1$39.95
ROHN 65G 30...1$3,406.00
20 Foot Telescopic...1$126.00
ROHN 55FK 30...1$6,675.00
ROHN 45G/55G...1$840.00
Non-Penetrating...1$131.00
#12 Solid Copper...1$24.95
Broadband Digital...1$26.95
50 Ft Aluminum...1$1,347.00
F Male to BNC...1$1.55
Template and...1$3.95
Goods Total901$392,285.40
View Cart Check out
Printer View Tell a Friend

CAT6 Direct Burial Flooded 23 AWG 4 pair CMXF Rated UTP Networking Cable 1000' Ft

Price$289.95
Manufacturer CodeCAT6-DB
Qty
AvailabilityUsually ships in 24 Hrs
ShippingCan ship Canada

Highlights

UV Rated Jacket
CMXF Exterior Rated
Cat-6 23 AWG/4 Pair
550 MHz Hi-Speed 
155Mbps TP-PMD/ CDDI
SOLID Bare Copper

Bulk Quantities Available Here!

3 Star CAT6-DB-GEL CAT6 UTP CMXF 4 Pair 23 AWG SBC UV Rated Jacket (UL/ETL)
Get a 1000 Foot Reel of Fast Category 6 at 550 MHz Flooded Ethernet Cable for Direct Burial Applications. This 23-AWG / 4 Pair Solid Bare Copper Conductor CAT6 Cable Features UTP CMXF Rating (Exterior/Flooded), UL Listed and meets or exceeds EIA/TIA 568 B.2-1, UL, CSA and ISO/IEC 11801 specifications. UV Rated Black Jacket with a Rip Cord and Surface Print.

 

Cable Specifications:
Conductor: 23 AWG Bare Solid Copper
Insulation: Solid Polyethylene

Industry Standards:
UL/CSA approved
ETL Verified to ANSI/TIE/EIA568A
ISO/IECC/1801

Applications:
10 Base-T (IEEEE 802.3)
100Vg-AnyLan (IEEEE 802.12)
Token Ring (IEEEE 802.5)
100 Base-T (IEEEE 802.3)
FDDI/CDDI 100 Mbps
ATM 155, 622 Mbps
1000 Base-T

 

Rate this product.
Product isn't rated yet. Write a review.

Category 6 Operates at up to 550 MHz, instead of the 350 MHz of standard CAT 5E cables. These CAT 6 cables are fully ANSI/TIA/EIA 568 B.2-1 compliant. CAT 6 cables are compatible with the current Category 6 Equipment, as well a Legacy and CAT 5. The Enhanced Electrical Performance of CAT 6 cables ensures capacity in supporting increased Bandwidth Application Requirements. Typical applications would include, Gigabit Ethernet, Distributed Video (CCTV) over CAT 5E, Voice over IP (VoIP). These CAT 6 cables offer Excellent Performance in all aspects of Data Transmission such as Frequency, Attenuation, Impedance, Capacitance, Resistance, and NEXT Level Performance.


UTP (unshielded twisted pair) cables are found in many Ethernet networks and telephone systems. For indoor telephone applications, UTP is often grouped into sets of 25 pairs according to a standard 25-pair color code originally developed by AT&T. A typical subset of these colors (white/blue, blue/white, white/orange, orange/white) shows up in most UTP cables. Typically, UTP would be used in an office setting.

STP (shielded twisted pair) cable for environments with lots of potential interference, or if you must place cable in extremely sensitive environments that may be susceptible to the electrical current in the UTP, shielded twisted pair may be the solution. Shielded cables can also help to extend the maximum distance of the cables.

FTP (foiled twisted pair) cable contains multiple pairs of copper wire enclosed in a sheath of aluminum foil. It's used in wiring systems in buildings or other environments where heavy noise adjacent to the wire might cause interference. The foil provides insulation not afforded by UTP (unshielded twisted pair), the most common kind of structural wiring. The disadvantage of FTP is that it requires somewhat more care in "earthing" (grounding) than UTP and electrical impedances must be matched when connecting to UTP. Typically, FTP might be used in a factory setting.


Solid core cable is supposed to be used for permanently installed runs. It is less flexible than stranded cable and is more prone to failure if repeatedly flexed. Stranded cable is used for fly leads at patch panel and for connections from wall-ports to end devices, as it resists cracking of the conductors. Stranded core is generally more expensive than solid core.

Connectors need to be designed differently for solid core than for stranded. Use of a connector with the wrong cable type is likely to lead to unreliable cabling. Plugs designed for solid and stranded core are readily available, and some vendors even offer plugs designed for use with both types. The punch-down blocks on patch-panel and wall port jacks are designed for use with solid core cable.


UL 444 is the defining document by Underwriters Laboratories (UL) for communications cables.  It is in this standard that the categories CM (non-plenum, non-riser), CMR (riser-rated) and CMP (plenum-rated) originate as cable types and cable markings.  These categories are commonly used in many other diversified documents such as Article 800 of the NFPA 70 (NEC) and are printed on communications cables.  Note that other categories were also defined in UL 444.  These include MP (multi-purpose cable), MPR (multi-purpose riser cable), MPP (multi-purpose plenum cable), CMX (communications cable, limited use), CL1 and CL2.  CL1 and CL2 are often associated with signal and alarm cable.  The remainder are not used in normal communications cabling.   

UL 1581 applies to non-plenum, non-riser cable. 
UL 1666 applies to riser-rated cable.  
UL 910 (also known as the modified Steiner Tunnel Test) applies to plenum-rated cable.

 

CM - Cable meeting UL 1685 (UL 1581, Sec. 1160) Vertical-Tray, CSA FT1

CMG - Cable meeting CSA FT4

CMR - Cable meeting UL 1666, CSA FT4. This cable is used in vertical tray applications such as cable runs between floors through cable risers. Riser rated cable must self extinguish and must prevent the flame from traveling up the cable in a vertical burn test. Cable that is to be run between floors in non-plenum areas is rated as riser cable. The fire requirements on riser cable are not as strict. Thus, plenum cable can always replace riser cable, but riser cable cannot replace plenum cable in plenum spaces

CMP - Cable meeting CSA FT6 or NFPA 262 (UL 910). This cable can be installed in air plenums and ducts in accordance with NEC Article 800. A Plenum is a hidden space within a building which is used for HVAC (Heating, Ventilation, and Air Conditioning) Plenum cable is coated with a fire-retardant coating. Plenum cable must not burn easily and must not emit toxic fumes when exposed to extreme heat. Because of these requirements, plenum cable is more expensive than non-plenum cable. Plenum cable is jacketed with a fire-retardant plastic jacket of either a low-smoke polyvinyl chloride (PVC) {patented 1987} or a fluorinated ethylene polymer (FEP). Polyolefin formulations, specifically based on polyethylene compounding had been developed by at least two companies in the early to mid-1990s; however, these were never commercialized and development efforts continue in these yet-untapped product potentials. Development efforts on a non-halogen plenum compound were announced in 2007 citing new flame-retardant synergist packages that may provide an answer for an yet-under-developed plenum cable market outside the United States. All materials intended for use on wire and cables to be placed in plenum spaces are designed to meet rigorous fire safety test standards in accordance with NFPA 262 and outlined in NFPA 90A. Plenum-rated cables are restricted to only allow certain chemicals for manufacture of the wire insulation and cable sheath. Typically this results in reduced flexibility of plastic cables, making it stiff and hard to bend. The bend radius may also be increased, and tight bends can potentially crack or tear the insulation and sheathing.

CMXF - Cable meeting UL 1581, Sec. 1080 (VW-1), CSA FT1; Exterior Flooded Core is typically a UV resistant black jacket with the interior containing an anti-water migration medium for direct burial network installations.

CMXT - Cable meeting UL 1581, Sec. 1080 (VW-1), CSA FT1; Exterior Shielded cable is used in environments were extra protection from outside interference is needed. This can be heavy machinery, transformers, generators or other equipment that has a high degree of EMI. (Electro Magnetic Interference) .

CMH - Cable meeting CSA FT1.


FT1 Vertical Flame Test - per C.S.A. C22.2 No. 0.3-92 Para 4.11.1

A finished cable shall not propagate a flame or continue to burn for more than one (1) minute after five (5) fifteen (15) second applications of the test flame. There is an interval of fifteen (15) seconds between flame applications. The flame test shall be performed in accordance with Para 4.11.1 of Canadian Standards Association (CSA) Standard C22.2 No. 0.3. In addition, if more than 25% of the indicator flag is burned, the test cable fails. FT1 Cables can be used in Combustible buildings.

FT4 Vertical Flame Test - Cables in Cable Trays per C.S.A. C22.2 No. 0.3-92 Para 4.11.4

Is similar to the UL-1685 Vertical Tray Flame Test, but is more severe. The FT4 test has its burner mounted at 20° from the horizontal with the burner ports facing up. The UL-1685 Vertical Tray has its burner at 0° from the horizontal. The FT4 samples must be larger than 13mm (.512″) in diameter. If not, then the cable samples are grouped in units of at least three (3) to obtain a grouped overall diameter of 13mm. The UL-1581 Vertical Tray does not distinguish on cable size. The FT4 has a maximum char height of 1.5 m (59″) measured from the lower edge of the burner face. The UL-1685 has a flame height allowable up to approximately 78″ measured from the burner. FT4 Cables can be used in Non-Combustible buildings.

FT6 Horizontal Flame & Smoke Test - per C.S.A. C22.2 No. 0.3-92 Appendix B

Products passing the FT6 Horizontal Flame and Smoke Test are designated FT6 in the column where the trade number appears. This test is for cables which must pass a Horizontal Flame and Smoke Test in accordance with ANSI/NFPA Standard 262-1985 (UL-910). The maximum flame spread shall be 1.50 meters (4.92 ft.). The smoke density shall be 0.5 at peak optical density and 0.15 at maximum average optical density.