Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN 4 inch...16$39.00
EZ TM-50-5U...2$115.00
ROHN 8 inch...19$79.00
EZ TM-50-U...30$164.00
EZ32A Telescopic...25$21.95
50 Foot Telescopic...21$282.00
ROHN 45G 30...1$1,260.00
225 FT RG11...16$99.00
ROHN Lightning...4$69.00
Rohn RSL Tower...13$372.00
ROHN 55G Complete...1$15,710.00
EZ32 Telescopic...16$14.95
ROHN 18 inch...21$86.00
3 inch wall...3$12.95
Rohn RSL Tower...20$60.50
4 inch Heavy...22$11.95
Rohn RSWGB...13$260.00
EZ32C Telescopic...22$24.95
Rohn RSL Tower...21$196.00
BNC Male to...1$1.90
ROHN Universal...14$70.38
Rohn RSL Tower...12$625.00
Telescopic...110$164.00
Dual Port Coaxial...5$1.65
ROHN 25G 45G...2$318.00
ROHN 12 inch...19$84.00
ROHN 55G Tower...3$778.50
Rohn RSL Tower...13$345.00
ROHN 25G Tower...2$335.00
53" X 2.00"...12$17.95
ROHN RSL 100...16$6,636.00
PPC Single...3$1.25
Rohn RSL Tower...24$58.00
RG11 RG7 RG6...4$24.95
50 FT RG11...19$35.00
ROHN 25G Antenna...3$415.00
PPC AquaTight...2$2.95
5' Foot X 1...23$16.30
ROHN Lightning...22$145.00
RASK12 Accessory...16$296.00
ROHN 25G 40...3$865.00
Rohn RSL Tower...16$1,540.00
12 inch Telescopic...26$23.50
TTRSL100 Safety...17$850.00
Rohn RSL Tower...9$592.00
Non-Penetrating...1$131.00
ROHN 24 inch...31$88.00
Rohn RSL RGKG...18$430.00
RG11 Tri Shield...1$44.95
Complete Grounding...20$32.00
ROHN 25AG 45AG...1$49.00
ROHN Tower...4$38.00
Rohn RSL Tower...18$3,710.00
Cat6 UTP 550...1$16.95
Telescopic...5$117.00
ROHN 65G Tower...2$780.00
18 inch Telescopic...22$28.40
Push on F Connector...2$0.79
PPC EX6XL PLUS...4$0.26
BNC Male to...4$1.55
Rohn RSL Tower...21$156.00
Rohn RSL Tower...13$1,150.00
21" J Pipe...5$19.95
EZ46-3PO Pitch...3$1.90
ROHN TUF TUG...12$335.00
50 Foot Telescopic...23$325.00
75 FT RG11...12$45.00
EZ60A 620 Steel...2$82.95
4 inch W type...2$10.95
ROHN RSL 100...20$6,090.00
ROHN H50 Telescopi...95$189.00
30 inch Telescopic...20$24.95
3/8 X 4 Foot...4$16.00
HOLLAND HFS...1$2.50
24 dB 1 GHz...2$2.65
DC Voltage...4$1.95
Holland TSTL...1$24.95
125 FT RG11...11$59.00
ROHNJACK G...2$329.00
ROHN Universal...1$595.00
ROHN 55G Tower...1$1,350.00
18 inch Deluxe...1$26.95
RG6 Underground...1$68.00
24 inch Deluxe...19$34.95
30 Foot Telescopic...2$206.00
Rohn RSL Tower...13$1,345.00
FAM-8HR 8 dB...1$2.75
EZ19B Roof...5$18.08
ROHN 25G Accessory...3$74.00
BNC Female...1$1.55
ROHN TUF TUG...1$325.00
ROHN 55G Tower...2$420.00
ROHN 65G Tower...1$425.00
ROHN Bolt Kit...1$14.95
EZ46-3 Pitch...6$3.95
ROHN 45G 10...1$570.00
5' Foot X 1...7$16.00
30 dB 2 Port...1$2.89
100 FT RG11...14$55.00
ROHN 65G Tower...1$734.00
HOLLAND 2-Way...2$1.60
RG6 Coaxial...4$3.95
RG6 Underground...3$62.00
RG11 RG7 RG6...1$12.95
Holland G-F81F*...2$0.39
ROHN 45G/55G...3$558.00
Thomas and...2$0.35
ROHN RSL TOWER...17$33.00
27 dB 2 Port...2$2.89
2 inch W type...1$10.95
ROHN 25G Top...7$298.00
3 dB Power...1$3.65
RG6 Twist-on...2$0.19
ROHN 12 inch...1$45.00
In-Line Cable...1$32.95
ROHN 65G Tower...1$390.00
ROHN 25G Tower...2$369.00
Six Port Keystone...2$1.05
ROHN 25G 35...2$897.00
HOLLAND 6 dB...2$2.65
ROHN 25G 10...2$156.00
Thomas and...1$4.90
ROHN 25G 30...1$694.00
ROHN 65g Top...3$319.95
RG6 Underground...1$34.00
Rohn RSL Tower...11$310.00
Holland F-811...1$0.15
Dual Port Coaxial...2$1.35
12 dB 2 Port...1$2.89
6 inch TV Antenna...2$10.82
45G Main Straight...1$13.95
1 HDMI + 3...1$18.00
HOLLAND 20...3$2.65
75 Ohm F Port...100$0.45
ROHN 25G Tower...1$289.00
Non-Penetrating...5$115.00
Holland Electronic...1$2.95
ROHN 25G Tower...4$358.00
ROHN 65G 20...1$3,582.00
Universal Tower...1$146.00
ROHN BGK2G...2$89.00
ROHN 25G Thrust...2$78.00
ROHN 25G Tower...4$260.00
ROHN 25G Tower...1$398.00
618 Telescopic...2$134.00
Protective...3$24.95
12 inch Deluxe...1$19.95
ROHN 65G 10...2$1,908.00
ROHN 65G 35...1$4,836.00
8-Way Vertical...1$9.95
EZ47-S1 2"...1$2.00
TTRSL50 Safety...1$580.00
ROHN 25G Complete...1$4,480.00
24 inch Telescopic...4$34.75
Gripple 1/8"...1$8.95
40 Ft Aluminum...2$1,648.00
BNC Connector...1$1.45
40 Foot Telescopic...1$309.00
ROHN 65G 10...1$1,695.00
Portable 3...1$27.95
Broadband Digital...1$26.95
PL-259 SO-239...1$6.59
20 Foot Telescopic...2$158.00
10' Foot X...1$27.00
8' Foot X 1...1$27.00
HOLLAND 8-Way...1$9.95
EZ48 48" Single...1$32.95
ROHN 25G Top...1$264.00
8' Foot X 1...1$27.95
ROHN 65G 45...1$6,253.00
2 Foot Roof...1$27.95
ROHN 55G Tower...1$298.00
Frequency Agile...1$27.95
3 inch HDG...2$13.95
ROHN 25G Tower...1$101.00
PPC EX6 PLUS...2$0.24
Cat6 Shielded...1$389.95
Dual Port Coaxial...4$1.30
Cat6 Aerial...1$310.70
1/8" Down...1$0.95
HOLLAND 12...2$2.65
8 inch Deluxe...1$16.95
16 dB 2 Port...1$2.89
CAT6 Direct...1$249.95
ROHN RSL 100...2$6,400.00
LNS5010 Black...1$39.95
DS-3000 J Pipe...1$28.95
PPC EX6WS AquaTigh...1$0.28
EZ TM-40-U...1$139.95
Holland HPF...1$2.45
Non-Penetrating...1$131.00
ROHN 8 inch...1$47.00
ROHN Bolt Kit...1$7.50
9 dB 2 Port...3$2.89
618 Telescopic...1$10.95
ROHN 45G Assembly...1$290.00
HOLLAND 9 dB...3$2.65
Commscope 2...1$1.25
FAM-6HR 6 dB...1$2.75
Telescopic...5$120.00
24 dB 2 Port...1$2.89
ROHN 25G Tower...1$239.00
TFC RG11-OR...1$225.00
Adjustable...1$8.95
ROHN D1130...2$379.00
ROHN 45G 55G...1$290.00
ROHN 45G Top...1$338.00
RG6 Underground...1$38.00
30 dB 1 GHz...1$2.65
EZ TM-20-U...1$83.00
RASK34 Accessory...1$425.00
FAM-16HR 16...25$2.45
Gripple Tensioning...1$87.00
ROHN 65G 40...1$5,090.00
RG6 RG59 RG58...1$8.95
1/4 inch Heavy...1$1.15
ROHN NPPK Non...2$469.95
ROHN 45AG Tower...1$14.95
Concrete Base...2$14.95
ROHN 25G Tower...1$7.95
ROHN 3 Foot...1$389.95
#12 Solid Copper...1$24.95
HOLLAND 16...1$2.65
Heavy Duty...1$15.95
ROHN 25G Tower...1$79.00
ROHN 25G 10...1$334.00
ROHN 55G Tower...1$753.00
BNC Female...1$1.10
ROHN 45G 55G...1$745.00
HDG 14 Gauge...1$19.95
27 dB 1 GHz...1$2.65
Goods Total1500$603,068.45
View Cart Check out

Sort by:

25G Bracketed

ROHN 25G 40 Foot Bracketed Tower 25BRKT040

ROHN 25G 40 Foot Bracketed Tower R-25BRKT040
Price$1,639.00
Manufacturer Code: 25BRKT040
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 50 Foot Bracketed Tower 25BRKT050

ROHN 25G 50 Foot Bracketed Tower R-25BRKT050
Price$1,790.00
Manufacturer Code: 25BRKT050
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 60 Foot Bracketed Tower 25BRKT060

ROHN 25G 60 Foot Bracketed Tower R-25BRKT060
Price$1,780.00
Manufacturer Code: 25BRKT060
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 70 Foot Bracketed Tower 25BRKT070

ROHN 25G 70 Foot Bracketed Tower R-25BRKT070
Price$2,130.00
Manufacturer Code: 25BRKT070
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 80 Foot Bracketed Tower 25BRKT080

ROHN 25G 80 Foot Bracketed Tower R-25BRKT080
Price$2,300.00
Manufacturer Code: 25BRKT080
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 90 Foot Bracketed Tower 25BRKT090

ROHN 25G 80 Foot Bracketed Tower R-25BRKT080
Price$2,475.00
Manufacturer Code: 25BRKT090
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 100 Foot Bracketed Tower 25BRKT100

ROHN 25G 100 Foot Bracketed Tower R-25BRKT100
Price$2,585.00
Manufacturer Code: 25BRKT100
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G Bracketed Tower

The 25G Bracketed Tower can be installed adjacent to buildings using a bracket to secure the tower in one or two locations along the height of the structure.

Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a susbstitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 25G Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.


 

ROHN 25G Bracketed Tower

DESIGN NOTES:
1.
Tower designs are in accordance with approved national standard ANSI/EIA-222-F.
2. All towers must have "fixed" bases. Pinned bases may not be used.
3. Designs assume transmission lines symmetrically placed as follows:
25G Tower - One 5/8" Line on each face ( Total =3)
4. Antennas and mounts assumed symmetrically placed at tower apex.
5. Allowable antenna areas assume all round antenna members.
6. Allowable flat-plate antenna areas, based on EIA RS-222-C, may be obtained by multiplying areas shown by 0.6.
7. All brackets are to be ROHN (P/N HBUTVRO)
8. The interface of tower brackets to supporting structure is to be designed by others and must support a minimum horizontal force of 815 lbs.

FEATURES:
o
Completely hot-dip galvanized after fabrication to provide absolute corrosion protection.
o Cross bracing is formed by a continuous solid rod bracing in a zig-zag pattern for strength.
o Pre-engineered loading charts meet varying individual specs and site conditions.
o Typical uses include small dishes, broadband, security and two-way communication.


ROHN 25G Bracketed



ROHN G-Series Bracketed Towers


Get Adobe Reader



This ROHN G-Series Bracketed Towers Guide will answer many questions you may have on this Product Line. For more detailed information and Specification Sheets covering many aspects of Various Parts, Accessories and Installation Scenarios... Please refer to the "ROHN 25G Tower" Link appearing in the Footer of this Page Below!


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections