Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN 65G 10...1$1,250.00
5' Foot X 1...1$16.00
Telescopic...10$120.00
3 Foot Tripod...1$36.88
ROHN 18 inch...9$86.00
20 Foot Telescopic...1$126.00
Dual Side Arm...1$169.95
1/4 inch Heavy...2$1.15
ROHN 25G Tower...1$824.00
EZ60A 620 Steel...1$82.95
20 Foot Telescopic...1$158.00
ROHN 12 inch...8$84.00
ROHN 55FK 20...1$6,430.00
6 inch TV Antenna...2$10.82
ROHN 25G Tower...1$1,985.00
EZ32A Telescopic...5$21.95
Complete Grounding...10$32.00
ROHN 25G Thrust...1$78.00
EZ32C Telescopic...6$24.95
125 FT RG11...3$59.00
2 Pair CAT...2$89.95
ROHN 25G Tower...1$289.00
Thomas & Betts...1$1.30
Cat6 UTP 550...1$1.30
HOLLAND 2-Way...1$2.60
ROHN 25G Tower...1$146.00
40 Foot Telescopic...1$309.00
ROHN 25G 40...2$865.00
ROHN 24 inch...8$88.00
EZ TM-40-U...1$139.95
ROHN H40 Telescopi...5$163.00
ROHN Universal...9$70.38
EZ32 Telescopic...14$14.95
5' Foot X 1...4$16.30
ROHN 25G Tower...1$205.00
ROHN 25G Tower...1$7.95
ROHN 65G 50...1$6,607.00
ROHN 25G Adjustabl...1$214.00
HOLLAND LA...1$11.95
10' Foot X...1$28.90
Dual Port Coaxial...1$1.35
12 inch Telescopic...12$23.50
50 FT RG11...5$35.00
Telescopic...15$117.00
ROHN 25G Adjustabl...1$203.00
18 inch Telescopic...11$28.40
ROHN RSL TOWER...7$33.00
ROHN H50 Telescopi...55$189.00
EZ19B Roof...2$18.08
Rohn RSL Tower...4$196.00
Rohn RSL Tower...6$1,345.00
ROHN RSL 100...9$6,636.00
Rohn RSL Tower...7$592.00
ROHN 4 inch...9$39.00
50 Foot Telescopic...8$282.00
ROHN 8 inch...10$79.00
75 FT RG11...3$45.00
TTRSL100 Safety...4$850.00
RASK12 Accessory...6$296.00
Rohn RSL Tower...3$58.00
PPC EX6 PLUS...1$0.24
ROHN RSL 100...2$6,090.00
30 inch Telescopic...8$24.95
ROHN Lightning...5$145.00
Gripple 1/8"...1$6.25
ROHN 65G Tower...1$1,350.00
HOLLAND 9 dB...1$2.65
PPC EX6XL PLUS...1$0.26
Rohn RSL Tower...4$310.00
ROHN 65g Top...1$319.95
ROHN TUF TUG...8$335.00
Rohn RSL Tower...3$345.00
Rohn RSL Tower...6$1,150.00
RG11 RG7 RG6...2$12.95
Telescopic...35$164.00
53" X 2.00"...2$17.95
ROHN TUF TUG...1$325.00
ROHN Universal...2$595.00
#12 Solid Copper...3$24.95
EZ46-3 Pitch...3$3.95
Broadband Digital...1$26.95
ROHN 65G Adjustabl...2$745.00
Rohn RSL RGKG...2$430.00
ROHN 45G 55G...2$745.00
Rohn RSWGB...5$260.00
Rohn RSL Tower...3$1,540.00
Rohn RSL Tower...5$625.00
4 inch Heavy...4$11.95
TTRSL50 Safety...1$580.00
24 inch Deluxe...4$34.95
Coaxial Cable...1$1.95
100 FT RG11...4$55.00
50 Foot Telescopic...1$325.00
Rohn RSL Tower...4$372.00
40 Foot Telescopic...1$240.00
MCR 3-Way Horizont...1$3.60
Non-Penetrating...1$131.00
ROHN 55G Tower...1$332.00
EZ TM-50-U...5$164.00
1 HDMI + 3...1$18.00
Holland G-F81F*...1$0.39
ROHN 45G 35...1$1,715.00
PPC EX6WS AquaTigh...1$0.28
ROHN GAS625...1$79.95
225 FT RG11...1$99.00
Adjustable...1$8.95
RG6 Underground...1$38.00
Heavy Duty...1$39.95
ROHN 45G 10...1$570.00
EZ DM 166-2...1$17.95
RG6 Coaxial...1$4.95
ROHN Universal...1$695.00
Thomas and...1$4.90
30 Foot Telescopic...1$166.00
EZ DM 166-2...1$22.00
Rohn RSL Tower...1$156.00
ROHN 55G Tower...1$778.50
ROHN 25G 10...1$156.00
3/16" Down...1$0.99
RG11 RG7 RG6...1$24.95
Rohn RSL Tower...2$3,710.00
21" J Pipe...2$19.95
ROHN 65G 20...1$2,600.00
DC Voltage...1$1.95
ROHN 65G 10...1$1,908.00
1/8" Down...1$0.95
RJ45 8P8C Plug...1$21.95
ROHN 25G Replaceme...1$32.95
ROHN 45G Tower...1$204.00
Six Port Keystone...1$1.05
ROHN 25G 20...1$540.00
HOLLAND 12...1$2.65
ROHN Leg Mounted...1$165.00
RG6 RG59 RG58...1$8.95
ROHN Tower...1$38.00
ROHN 45G 40...1$1,605.00
HOLLAND 6 dB...1$2.65
ROHN 25G Complete...1$4,480.00
ROHN 55G Tower...1$298.00
8' Foot X 1...1$27.95
HOLLAND 20...1$2.65
ROHN BGK2G...1$89.00
Rohn RSL Tower...1$60.50
ROHN 65G 10...1$1,695.00
ROHN 25G Antenna...1$415.00
5/8 X 8 Foot...1$16.95
LNS5000 Big...1$67.95
Goods Total489$199,505.16
View Cart Check out

Sort by:

25G Bracketed

ROHN 25G 40 Foot Bracketed Tower 25BRKT040

ROHN 25G 40 Foot Bracketed Tower R-25BRKT040
Price$1,639.00
Manufacturer Code: 25BRKT040
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 50 Foot Bracketed Tower 25BRKT050

ROHN 25G 50 Foot Bracketed Tower R-25BRKT050
Price$1,790.00
Manufacturer Code: 25BRKT050
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 60 Foot Bracketed Tower 25BRKT060

ROHN 25G 60 Foot Bracketed Tower R-25BRKT060
Price$1,780.00
Manufacturer Code: 25BRKT060
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 70 Foot Bracketed Tower 25BRKT070

ROHN 25G 70 Foot Bracketed Tower R-25BRKT070
Price$2,130.00
Manufacturer Code: 25BRKT070
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 80 Foot Bracketed Tower 25BRKT080

ROHN 25G 80 Foot Bracketed Tower R-25BRKT080
Price$2,300.00
Manufacturer Code: 25BRKT080
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 90 Foot Bracketed Tower 25BRKT090

ROHN 25G 80 Foot Bracketed Tower R-25BRKT080
Price$2,475.00
Manufacturer Code: 25BRKT090
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G 100 Foot Bracketed Tower 25BRKT100

ROHN 25G 100 Foot Bracketed Tower R-25BRKT100
Price$2,585.00
Manufacturer Code: 25BRKT100
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 25G Bracketed Tower

The 25G Bracketed Tower can be installed adjacent to buildings using a bracket to secure the tower in one or two locations along the height of the structure.

Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a susbstitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 25G Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.


 

ROHN 25G Bracketed Tower

DESIGN NOTES:
1.
Tower designs are in accordance with approved national standard ANSI/EIA-222-F.
2. All towers must have "fixed" bases. Pinned bases may not be used.
3. Designs assume transmission lines symmetrically placed as follows:
25G Tower - One 5/8" Line on each face ( Total =3)
4. Antennas and mounts assumed symmetrically placed at tower apex.
5. Allowable antenna areas assume all round antenna members.
6. Allowable flat-plate antenna areas, based on EIA RS-222-C, may be obtained by multiplying areas shown by 0.6.
7. All brackets are to be ROHN (P/N HBUTVRO)
8. The interface of tower brackets to supporting structure is to be designed by others and must support a minimum horizontal force of 815 lbs.

FEATURES:
o
Completely hot-dip galvanized after fabrication to provide absolute corrosion protection.
o Cross bracing is formed by a continuous solid rod bracing in a zig-zag pattern for strength.
o Pre-engineered loading charts meet varying individual specs and site conditions.
o Typical uses include small dishes, broadband, security and two-way communication.


ROHN 25G Bracketed



ROHN G-Series Bracketed Towers


Get Adobe Reader



This ROHN G-Series Bracketed Towers Guide will answer many questions you may have on this Product Line. For more detailed information and Specification Sheets covering many aspects of Various Parts, Accessories and Installation Scenarios... Please refer to the "ROHN 25G Tower" Link appearing in the Footer of this Page Below!


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections