Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
40 Foot Telescopic...1$240.00
ROHN 12 inch...7$84.00
Push on F Connector...4$0.79
24 inch Telescopic...5$34.75
Complete Grounding...11$32.00
30 inch Telescopic...10$24.95
EZ19B Roof...3$18.08
Channel Master...1$1.40
24 inch Deluxe...7$34.95
ROHN 24 inch...13$88.00
ROHN 25G Tower...1$985.00
ROHN 25G 45G...3$210.00
Cat6 UTP 550...1$1.70
ROHN 18 inch...12$86.00
ROHN RSL TOWER...9$33.00
MM2 Universal...1$13.95
EZ19A Roof...1$12.85
50 Foot Telescopic...4$282.00
Telescopic...5$120.00
ROHN 55G Tower...1$1,350.00
ROHN H30 Telescopi...1$22.95
EZ32A Telescopic...9$21.95
ROHN 65G Section...1$84.95
ROHN 65g Top...1$319.95
75 FT RG11...11$45.00
ROHN BGK2G...2$89.00
EZ TM-30-U...1$112.00
EZ TM-50-U...12$164.00
30 Foot Telescopic...3$166.00
ROHN 25G 35...1$897.00
100 FT RG11...6$55.00
ROHN 65G Anti...1$960.00
FAM-16 dB In...1$2.25
ROHN 25G 45G...2$318.00
5' Foot X 1...10$16.30
ROHN 4 inch...10$39.00
HOLLAND HFS...1$3.55
ROHN Universal...11$70.38
EZ32C Telescopic...7$24.95
18 inch Telescopic...8$28.40
Telescopic...5$144.00
225 FT RG11...7$99.00
Dual Port Coaxial...2$1.35
TTRSL100 Safety...7$850.00
Rohn RSL Tower...6$58.00
Rohn RSL Tower...9$592.00
ROHN TUF TUG...8$335.00
53" X 2.00"...4$17.95
4 inch Heavy...16$11.95
Rohn RSL Tower...3$156.00
ROHN 55G Top...1$425.00
RASK12 Accessory...5$296.00
Telescopic...30$164.00
Rohn RSL Tower...5$1,150.00
50 FT RG11...4$35.00
ROHN Universal...2$695.00
ROHN 25G Accessory...3$74.00
ROHN TUF TUG...1$325.00
ROHN 65G 20...1$3,582.00
ROHN 8 inch...9$79.00
ROHN H50 Telescopi...50$189.00
Rohn RSL RGKG...6$430.00
Rohn RSL Tower...6$1,345.00
5 Foot Heavy...2$79.95
ROHN Bolt Kit...1$7.50
ROHN Lightning...7$145.00
ROHN RSL 100...7$6,090.00
125 FT RG11...2$59.00
Dual Side Arm...2$159.95
ROHN Complete...1$0.00
Rohn RSL Tower...7$1,540.00
ROHN 25G 10...4$156.00
HOLLAND 2-Way...1$2.60
Rohn RSL Tower...8$625.00
ROHN RSL 100...7$6,636.00
ROHN 65G Tower...1$665.00
DC Voltage...1$1.95
50 Foot Telescopic...11$325.00
ROHN 45G 10...1$570.00
Gripple 1/8"...2$6.25
"Y" Style Chimney...1$17.50
75 Ohm F Port...25$0.45
5' Foot X 1...1$16.00
ROHN Bolt Kit...1$14.95
Rohn RSL Tower...8$310.00
ROHN 25G Antenna...2$415.00
EZ46-3PO Pitch...2$1.90
Rohn RSL Tower...5$372.00
3 inch HDG...1$13.95
ROHN 6 inch...1$39.00
8 inch TV Antenna...1$13.90
ROHN 25G Tower...1$97.00
Square U-Bolt...1$6.45
Rohn RSL Tower...6$3,710.00
ROHN 25G Tower...4$335.00
EZ32 Telescopic...9$14.95
PPC AquaTight...1$2.95
ROHN Lightning...2$69.00
EZ46-3 Pitch...3$3.95
20 Foot Telescopic...1$126.00
FAM-8HR 8 dB...1$2.75
Rohn RSL Tower...8$345.00
Telescopic...10$117.00
ROHN 45G Tower...1$240.00
ROHN 55G 35...1$2,230.00
LNS5000 Big...1$67.95
RG11 RG7 RG6...2$24.95
Template and...1$3.95
Rohn RSL Tower...2$60.50
RG6 RG59 RG58...1$8.95
HOLLAND 2-Way...1$2.60
HOLLAND HFS...1$2.50
Holland HPF...1$2.45
ROHN 25G Tower...1$110.00
12 inch Telescopic...11$23.50
Dual Port Coaxial...1$1.65
Rohn RSL Tower...3$196.00
HOLLAND 20...1$2.65
3 inch wall...1$12.95
Rohn Universal...1$49.00
Rohn RSWGB...4$260.00
ROHN 45G Tower...2$204.00
BNC Male to...1$1.55
3S-2025 Crossover...1$26.95
ROHN 25G Tower...2$260.00
ROHN 12 inch...1$45.00
Frequency Agile...1$27.95
7 Inch Cable...1$2.50
ROHN 45G 55G...2$290.00
ROHN Tower...1$21.00
EZ60A 620 Steel...1$82.95
3/8 X 4 Foot...1$16.00
ROHN Tower...3$38.00
ROHN 8 inch...1$47.00
Non-Penetrating...2$115.00
DS-3000 J Pipe...1$28.95
ROHN 25G Tower...1$824.00
EZ DM 166-2...1$22.00
3S60 620 Plastic...1$108.00
1/8" Down...1$0.95
4 inch TV Antenna...1$12.00
ROHN 25G Assembly...1$186.00
ROHN 65G Tower...1$780.00
ROHN 55G Tower...1$332.00
4 inch W type...1$10.95
ROHN 65G 20...1$2,600.00
RG6 Underground...1$34.00
Protective...1$24.95
Six Port Keystone...1$1.05
ROHN 65G 20...1$1,668.00
Concrete Base...1$14.95
2 inch W type...1$10.95
Portable 3...1$27.95
BNC Male to...1$1.55
ROHN 45G 30...1$1,260.00
ROHN 18 inch...1$47.00
Broadband Digital...1$26.95
ROHN 45G 45...1$2,150.00
Gripple 3/8"...1$32.95
3 Foot Tripod...1$28.60
8' Foot X 1...1$27.00
ROHN 25G 45G...1$316.00
HOLLAND 9 dB...1$2.65
ROHN 25G 30...1$694.00
Goods Total633$236,504.73
View Cart Check out

Sort by:

45G Bracketed

ROHN 45G 40 Foot Bracketed Tower 45BRKT040

ROHN 45G 40 Foot Bracketed Tower R-45BRKT040
Price$2,360.00
Manufacturer Code: 45BRKT040
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 50 Foot Bracketed Tower 45BRKT050

ROHN 45G 50 Foot Bracketed Tower R-45BRKT050
Price$2,695.00
Manufacturer Code: 45BRKT050
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 60 Foot Bracketed Tower 45BRKT060

ROHN 45G 60 Foot Bracketed Tower R-45BRKT060
Price$3,025.00
Manufacturer Code: 45BRKT060
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 70 Foot Bracketed Tower 45BRKT070

ROHN 45G 70 Foot Bracketed Tower R-45BRKT070
Price$3,360.00
Manufacturer Code: 45BRKT070
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 80 Foot Bracketed Tower 45BRKT080

ROHN 45G 80 Foot Bracketed Tower R-45BRKT080
Price$3,690.00
Manufacturer Code: 45BRKT080
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 90 Foot Bracketed Tower 45BRKT090

ROHN 45G 80 Foot Bracketed Tower R-45BRKT090
Price$4,020.00
Manufacturer Code: 45BRKT090
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 100 Foot Bracketed Tower 45BRKT100

ROHN 45G 100 Foot Bracketed Tower R-45BRKT100
Price$4,355.00
Manufacturer Code: 45BRKT100
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

The 45G Bracketed Tower can be installed adjacent to buildings using a bracket to secure the tower in one or two locations along the height of the structure.

Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a susbstitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 45G Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control. 

 


 

ROHN 45G Bracketed Tower

DESIGN NOTES:
1.
Tower designs are in accordance with ANSI/EIA-222-F.
2. All towers must have "fixed" bases. Pinned bases may not be used.
3. Designs assume transmission lines symmetrically placed as follows:
45G Tower - One 1/2" and One 7/8" Line on each face ( Total =6)
4. Antennas and mounts assumed symmetrically placed at tower apex.
5. Allowable antenna areas assume all round antenna members.
6. Allowable flat-plate antenna areas, based on EIA RS-222-C, may be obtained by multiplying areas shown by 0.6.
7. All brackets are to be ROHN (P/N HBUTVRO)
8. The interface of tower brackets to supporting structure is to be designed by others and must support a minimum horizontal force of 1810 lbs.

FEATURES:
o
Completely hot-dip galvanized after fabrication to provide absolute corrosion protection.
o Cross bracing is formed by a continuous solid rod bracing in a zig-zag pattern for strength.
o Pre-engineered loading charts meet varying individual specs and site conditions.
o Typical uses include small dishes, broadband, security and two-way communication.


ROHN 25G Bracketed



ROHN G-Series Bracketed Towers


Get Adobe Reader



This ROHN G-Series Bracketed Towers Guide will answer many questions you may have on this Product Line. For more detailed information and Specification Sheets covering many aspects of Various Parts, Accessories and Installation Scenarios... Please refer to the "ROHN 45G Tower" Link appearing in the Footer of this Page Below!


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections