Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN 25G Tower...1$369.00
BNC Female...1$2.25
ROHN 25G Tower...2$79.00
ROHN 65G Anti...3$960.00
DC Voltage...1$1.95
ROHN Bolt Kit...2$7.50
225 FT RG11...7$99.00
50 FT RG11...6$35.00
125 FT RG11...3$59.00
ROHNJACK G...1$329.00
100 FT RG11...4$55.00
Push on F Connector...2$0.79
75 FT RG11...8$45.00
20 Foot Telescopic...1$158.00
Heavy Duty...1$9.95
Commscope ...1$3.60
EZ TM-40-U...2$139.95
ROHN 18 inch...10$86.00
ROHN 12 inch...6$84.00
ROHN 18 inch...1$47.00
ROHN 4 inch...5$39.00
Dual Port Coaxial...3$1.30
ROHN EP25345...1$89.00
30 inch Telescopic...14$24.95
ROHN Telescopic...1$114.00
ROHN 55G Tower...1$298.00
EZ46-3PO Pitch...2$1.90
27" - 42" FLAT...1$193.00
Holland HPF...2$2.45
Complete Grounding...7$32.00
Heavy Duty...1$18.95
Holland TSTL...1$24.95
Butyl Weather...1$3.20
53" X 2.00"...5$17.95
24 inch Telescopic...3$34.75
Telescopic...10$120.00
TFC RG11-OR...1$225.00
21" J Pipe...2$19.95
Rohn RSL Tower...4$592.00
5' Foot X 1...8$16.30
Rohn RSL Tower...10$3,710.00
ROHN 8 inch...8$79.00
Telescopic...55$164.00
18 inch Telescopic...8$28.40
RG6 Underground...2$68.00
EZ TM-50-U...9$164.00
Rohn RSL Tower...3$1,150.00
EZ32A Telescopic...9$21.95
12 inch Telescopic...6$23.50
ROHN RSL 100...7$6,090.00
Rohn RSL Tower...7$310.00
ROHN 24 inch...4$88.00
Rohn RSL Tower...7$625.00
Telescopic...10$78.00
24 inch Deluxe...9$34.95
RG11 Quad Shield...20$154.95
50 Foot Telescopic...4$325.00
ROHN RSL TOWER...4$33.00
4 inch Heavy...6$11.95
RASK12 Accessory...8$296.00
ROHN H50 Telescopi...15$189.00
ROHN 25G 10...2$156.00
ROHN Lightning...1$69.00
4 inch TV Antenna...1$12.00
ROHN 55G Tower...2$420.00
EZ32C Telescopic...6$24.95
ROHN 45G/55G...1$558.00
TTRSL50 Safety...1$580.00
Rohn RSL Tower...4$372.00
Rohn RSL Tower...5$196.00
Rohn RSL Tower...8$1,540.00
Rohn RSWGB...4$260.00
ROHN RSL 100...3$6,636.00
ROHN 25G Top...1$298.00
ROHN Universal...4$70.38
HOLLAND 12...1$2.65
ROHN BGK2G...1$89.00
HOLLAND 16...1$2.65
ROHN 25G Tower...1$335.00
27 dB 1 GHz...1$2.65
Rohn RSL Tower...4$1,345.00
Non-Penetrating...3$131.00
EZ60 620 Plastic...1$7.95
ROHN 45G 40...2$1,605.00
PPC AquaTight...3$2.95
Rohn RSL Tower...6$58.00
ROHN RSL 80...1$5,480.00
12 dB 2 Port...1$2.89
ROHN 25G Adjustabl...2$186.00
8' Foot X 1...1$27.00
Turnbuckle...1$3.05
RG11 RG7 RG6...1$12.95
Rohn RSL Tower...3$156.00
RG6 Coaxial...1$6.95
Thomas and...1$0.35
EZ32 Telescopic...3$14.95
Rohn RSL Tower...6$60.50
Rohn RSL Tower...6$345.00
ROHN Bolt Kit...2$14.95
ROHN TUF TUG...5$335.00
ROHN Universal...1$695.00
ROHN Lightning...5$145.00
EZ19B Roof...1$18.08
ROHN H40 Telescopi...5$163.00
36 Inch Roof...1$49.00
ROHN 25G Antenna...2$415.00
ROHN 65G 20...1$2,600.00
ROHN Tower...1$38.00
ROHN 45G 55G...1$156.00
Rohn RSL RGKG...3$430.00
Broadband Digital...1$26.95
50 Foot Telescopic...1$282.00
ROHN 45GSR...1$1,800.00
Protective...1$24.95
Telescopic...5$117.00
TTRSL100 Safety...4$850.00
EZ DM 166-2...1$22.00
4 inch W type...1$10.95
ROHN 25G Assembly...1$186.00
Holland G-F81F*...1$0.39
ROHN 25G Accessory...1$74.00
Dual Port Coaxial...1$1.35
ROHN 25G Tower...1$101.00
ROHN 65G Adjustabl...1$745.00
LNS5000 Big...1$67.95
ROHN 55G 40...1$2,005.00
4 inch W type...1$10.95
5/16" Extra...1$340.00
ROHN TUF TUG...1$325.00
ROHN 8 inch...2$47.00
RCA Male to...1$1.10
ROHN 25G Complete...1$4,480.00
EZ60A 620 Steel...1$82.95
Six Port Keystone...1$1.05
ROHN RSL 100...1$6,400.00
618 Telescopic...2$134.00
Channel Master...2$1.40
ROHN 25G 40...1$865.00
27 dB 2 Port...1$2.89
ROHN 45G 30...1$1,260.00
18 inch Deluxe...1$26.95
EZ30 30" Single...1$17.95
HT-2096 RJ...1$24.95
EZ TS-50 Free...1$69.95
16 dB 2 Port...2$2.89
HOLLAND 2-Way...2$2.60
RG6 Underground...1$38.00
ROHN 25G 45G...1$210.00
FAM-3 dB In...1$2.25
In-Line Power...1$28.95
ROHN 25G Tower...1$478.00
ROHN 65G 35...1$4,836.00
HOLLAND 8-Way...1$9.95
75 Ohm F Port...25$0.45
ROHN 65G 10...1$1,695.00
5' Foot X 1...1$16.00
HOLLAND 20...1$2.65
BNC Male to...1$1.55
ROHN 45G Tower...1$204.00
ROHN 25G 45G...1$318.00
Goods Total555$223,622.18
View Cart Check out

45G Self Supporting

ROHN 45G 10 Foot Self Supporting Tower 45SS010

ROHN 45G 10 Foot Self Supporting Tower R-45SS010
Price$570.00
Manufacturer Code: 45SS010
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 20 Foot Self Supporting Tower 45SS020

ROHN 45G 20 Foot Self Supporting Tower R-45SS020
Price$915.00
Manufacturer Code: 45SS020
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 30 Foot Self Supporting Tower 45SS030

ROHN 45G 30 Foot Self Supporting Tower R-45SS020
Price$1,260.00
Manufacturer Code: 45SS030
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 35 Foot Self Supporting Tower 45SS035

ROHN 45G 35 Foot Self Supporting Tower R-45SS035
Price$1,715.00
Manufacturer Code: 45SS035
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 40 Foot Self Supporting Tower 45SS040

ROHN 45G 40 Foot Self Supporting Tower R-45SS040
Price$1,605.00
Manufacturer Code: 45SS040
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

ROHN 45G 45 Foot Self Supporting Tower 45SS045

ROHN 45G 45 Foot Self Supporting Tower R-45SS045
Price$2,150.00
Manufacturer Code: 45SS045
Average Rating: 5
Top Cap:
Grounding:
Qty:
Add to Cart Read More

The Self-Supporting G-Series Towers offer an easy, low-cost solution to get light weight antennas in the air quickly. By using the G-Series tower as a self-supporting structure, you minimize land area usage. They are functional in a wide variety of wind speeds, with and without ice. See ROHN´s standard design to help identify the right structure for your project. Theses are the same sturdy, robust tower sections that ROHN has fabricated for years. Each larger model allows for more loading capacity.

Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a susbstitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 45G Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.

 


 

ROHN Self Supporting Tower Rev.F

ROHN Self Supporting Tower Rev.G

DESIGN NOTES:
1.
Tower designs are in accordance with approved national standard ANSI/EIA-222-F.
2. All towers must have "fixed" bases. Pinned bases may not be used.
3. Designs assume transmission lines symmetrically placed as follows:
25G Tower - One 5/8" Line on each face ( Total =3)
45G Tower - One 7/8" Line on each face ( Total = 3 @ 7/8" & 3 @ 1/2")
55G & 65G Towers - Two 7/8" Lines on each face ( Total =6)
4. Antennas and mounts assumed symmetrically placed at tower apex.
5. Allowable antenna areas assume all round antenna members.
6. Allowable flat-plate antenna areas, based on EIA RS-222-C, may be obtained by multiplying areas shown by 0.6.
7. Standard foundation designs are based on Rev. F normal soil and Rev. G presumptive clay soil parameters. .

FEATURES:
o
Completely hot-dip galvanized after fabrication to provide absolute corrosion protection.
o Cross bracing is formed by a continuous solid rod bracing in a zig-zag pattern for strength.
o Pre-engineered loading charts meet varying individual specs and site conditions.
o Typical uses include small dishes, broadband, security and two-way communication.


ROHN 25G Buyers Guide



ROHN G-Series Self Supporting Towers


Get Adobe Reader



This ROHN G-Series Self Supporting Towers Guide will answer many questions you may have on this Product Line. For more detailed information and Specification Sheets covering many aspects of Various Parts, Accessories and Installation Scenarios... Please refer to the "ROHN 45G Tower" Link appearing in the Footer of this Page Below!


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections