Coaxial Cable TV Surge Protector

× Coaxial Cable TV Surge Protector was added to your Shopping Cart.
Price$1.95
Manufacturer CodeVSGB1GTSS
Qty
AvailabilityUsually ships in 24 Hrs

Highlights
1 GHz.
Single Port
Machined Threads
DC Breakdown:
120 Volts min.
297 Volts max.
Surge Current:
10kA
Capacitance:
2 pF max.

Bulk Quantities Available Here!

Viewsonics VSGB1GTSS Coaxial Cable TV urge Protector and Ground Block
is a high performance Surge Protector ground block with machined threads and ground screw configuration. Expected Performance is as noted above. Ground block accomodates a 12 AWG Ground Wire with ease
.

Info. sheet



Info. Sheet


Get Adobe Reader




This is what you want to use to Ground your Cable TV or HDTV Antenna Coaxial Cable Outside before bringing the Signal Inside. Specifically Designed to respond to both AC and DC Transient Voltages that might harm your System. This way, Lightning Strikes and Power Surges have an opportunity to arrest before reaching your TV and Entertainment Electronics. The grounding Block will convey this unwanted Electrical Energy to a Ground Rod via a Copper Ground Wire that you Install (not included). Consult your Local Building Code and NEC for guidance to Properly Grounding your HD TV Antenna, Cable TV, WI-FI, Wireless Internet, Business Band, CB or Amateur Radio Antenna Installation.
Specification Sheet
grounding type
Ground Blocks

GENERAL USE

The ROHN RSL is a light weight self-supporting tower designed for use in broadband, public safety and security applications. The RSL reaches above line-of-site obstacles such as tree tops, hilly terrain and buildings. The RSL is shipped knocked down to reduce shipping cost and time.

STRUCTURE CLASSIFICATION = I

That due to height, use or location poses a low hazard to human life and damage to property in the event of failure and/or used for services that are optional and/or where a delay in returning the services would be acceptable.

EXPOSURE CATEGORY = C

Open terrain with scattered obstructions having heights generally less than 30 ft (9.1 m) This category includes flat, open country, grasslands and shorelines in hurricane prone regions.

TOPOGRAPHICAL CATEGORY = 1

No abrupt changes in general topography, e.g. flat or rolling terrain, no wind speed-up consideration shall be required. 

  3-SECOND GUST WIND SPEED WITH ICE = 40 MPH

 

 DESIGN ICE THICKNESS = 1.0" 

EARTHQUAKE SPECTRAL RESPONSE ACCELERATION, Ss = 2.50 

 

ROHN RSL Tube Braced Class II

ROHN RSL Tube Braced Class II

The tabulated allowable effective projected areas (EPA) are limited to a maximum recommended value of 80 (ft2). EPA values shown as " - " indicate tower kit is not applicable for the corresponding wind speed. Site-specific designs are available upon request.

 

TUBE BRACING
RSL Tube Braced Class II

ROHN RSL Tube Braced Class II

GENERAL USE

The ROHN RSL is a light weight self-supporting tower designed for use in broadband, public safety and security applications. The RSL reaches above line-of-site obstacles such as tree tops, hilly terrain and buildings. The RSL is shipped knocked down to reduce shipping cost and time.

 

STRUCTURE CLASSIFICATION = I

That due to height, use or location poses a low hazard to human life and damage to property in the event of failure and/or used for services that are optional and/or where a delay in returning the services would be acceptable.

 

EXPOSURE CATEGORY = C

Open terrain with scattered obstructions having heights generally less than 30 ft (9.1 m) This category includes flat, open country, grasslands and shorelines in hurricane prone regions.

 

TOPOGRAPHICAL CATEGORY = 1

No abrupt changes in general topography, e.g. flat or rolling terrain, no wind speed-up consideration shall be required. 

 

3-SECOND GUST WIND SPEED WITH ICE = 40 MPH

 

DESIGN ICE THICKNESS = 1.0"

 

EARTHQUAKE SPECTRAL RESPONSE ACCELERATION, Ss = 2.50

 

ROHN RSL Tube Braced Class II
ROHN RSL Tube Braced Class II

The tabulated allowable effective projected areas (EPA) are limited to a maximum recommended value of 80 (ft2). EPA values shown as " - " indicate tower kit is not applicable for the corresponding wind speed. Site-specific designs are available upon request.

TUBE BRACING
CLASS II LOADING