(6) 5/16" x 2 1/2" Lag Screws
Washer Hex Head
Chrome Finish
(3) 3 x 1.5" Pitch Pads
Professional Grade

Bulk Quantities Available Here!

EZ 46-3 Pitch Pad Kit with Screws
Made in the USA!Made in the USA!
Complete with (6) Hex Head with Integral Washer Lag Screws (5/16 inches long by 2 1/2 inch Diameter, Chrome Finish, Self Starting) (3) Pitch Pads (3 inches by 1.5 inches), Professional Grade Supplied by the Manufacturer. Place these Pads between the Mounting Screw Tabs and the Wall (or other mounting surface) as to Pierce the Pad with the Mounting Screw as it Penetrates the Wall Surface, Compressing the Pad between the Tab and the Wall as it Tightens. The 2 1/2 inch length screw is the most popular for the majority of Antenna Mast Bracket Installations.

 


 

Note

Use this kit with any HD TV Antenna Mast Wall Mount, Tripod or Roof Mount to securely affix the Mount or Bracket to the mounting surface with the Pitch Pad Moisture Penetration barrier to preserve the integrity of the wall or mounting surface and thereby Weather-Proof Bracket Mounting to Exterior Surfaces.

GENERAL USE

The ROHN RSL is a light weight self-supporting tower designed for use in broadband, public safety and security applications. The RSL reaches above line-of-site obstacles such as tree tops, hilly terrain and buildings. The RSL is shipped knocked down to reduce shipping cost and time.

 

 

STRUCTURE CLASSIFICATION = I

 

 

That due to height, use or location poses a low hazard to human life and damage to property in the event of failure and/or used for services that are optional and/or where a delay in returning the services would be acceptable.

 

EXPOSURE CATEGORY = C

 

Open terrain with scattered obstructions having heights generally less than 30 ft (9.1 m) This category includes flat, open country, grasslands and shorelines in hurricane prone regions.

 

TOPOGRAPHICAL CATEGORY = 1

 

No abrupt changes in general topography, e.g. flat or rolling terrain, no wind speed-up consideration shall be required. 

 

3-SECOND GUST WIND SPEED WITH ICE = 40 MPH

 

DESIGN ICE THICKNESS = 1.0"

 

EARTHQUAKE SPECTRAL RESPONSE ACCELERATION, Ss = 2.50

 

ROHN RSL Angle Braced Class II
ROHN RSL Angle Braced Class II

The tabulated allowable effective projected areas (EPA) are limited to a maximum recommended value of 80 (ft2). EPA values shown as " - " indicate tower kit is not applicable for the corresponding wind speed. Site-specific designs are available upon request.

ANGLE BRACING
CLASS II LOADING