Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
EZ32 Telescopic...17$14.95
Holland Electronic...2$2.95
225 FT RG11...11$99.00
24 dB 1 GHz...1$2.65
ROHN Telescopic...1$114.00
24 inch Deluxe...8$34.95
ROHN TUF TUG...1$325.00
ROHN 55G Tower...3$332.00
Rohn RSL Tower...11$196.00
TTRSL50 Safety...4$580.00
ROHNJACK G...1$329.00
EZ TS-50 Free...1$69.95
Banana Plug...1$3.50
ROHN RSL 100...10$6,090.00
125 FT RG11...11$59.00
ROHN 8 inch...9$79.00
EZ19B Roof...5$18.08
30 inch Telescopic...12$24.95
TTRSL100 Safety...9$850.00
ROHN RSL 100...12$6,636.00
50 Foot Telescopic...9$325.00
Commscope 2...1$1.25
ROHN RSL TOWER...9$33.00
4 inch TV Antenna...2$12.00
Rohn RSL Tower...14$60.50
57" Inch X...2$18.95
ROHN 12 inch...13$84.00
100 FT RG11...9$55.00
5' Foot X 1...13$16.30
ROHN 18 inch...18$86.00
Rohn RSL Tower...10$310.00
50 Foot Telescopic...10$282.00
Rohn RSL RGKG...11$430.00
Rohn RSL Tower...7$1,150.00
DS-3000 J Pipe...5$28.95
ROHN Rubber...1$110.00
ROHN 65G 40...3$5,090.00
3 dB Power...5$3.65
ROHN 65G Tower...1$780.00
ROHN Universal...8$70.38
RG11 RG7 RG6...2$24.95
Rohn RSL Tower...9$1,540.00
Rohn RSL Tower...13$1,345.00
Rohn RSL Tower...7$372.00
Rohn RSL Tower...11$58.00
EZ32A Telescopic...15$21.95
HOLLAND LA...2$11.95
21" J Pipe...1$19.95
PPC Single...1$1.25
Rohn RSL Tower...15$592.00
ROHN H50 Telescopi...40$189.00
75 FT RG11...12$45.00
ROHN 24 inch...17$88.00
RASK12 Accessory...8$296.00
ROHN 25G Tower...2$335.00
12 inch Telescopic...16$23.50
18 inch Telescopic...21$28.40
"Z" Style Chimney...1$17.90
ROHN 45G 45...1$2,150.00
ROHN 4 inch...11$39.00
Complete Grounding...15$32.00
ROHN Bolt Kit...2$7.50
LNS5010 Black...1$39.95
50 FT RG11...6$35.00
Rohn RSL Tower...7$625.00
ROHN TUF TUG...12$335.00
Rohn RSL Tower...7$3,710.00
ROHN 25G Tower...3$358.00
4 inch W type...3$10.95
EZ46-3PO Pitch...3$1.90
ROHN Tower...4$38.00
EZ46-3 Pitch...1$3.95
4 inch Heavy...17$11.95
Holland TSTL...1$24.95
18 inch Deluxe...1$26.95
PPC EX6XL PLUS...1$0.26
Holland HPF...1$2.45
Dual Port Coaxial...2$1.65
75 Ohm F Port...25$0.45
EZ32C Telescopic...14$24.95
ROHN GAS604...1$69.95
ROHN 25G 45G...3$318.00
ROHN 25G 40...4$865.00
2 inch W type...1$10.95
ROHN 65G 20...2$2,600.00
EZ46-5 Pitch...1$4.50
EZ TM-50-U...13$164.00
Rohn RSWGB...11$260.00
Channel Master...2$1.40
ROHN 25G Accessory...4$74.00
ROHN BGK2G...1$89.00
HOLLAND 16...1$2.65
ROHN 25G Tower...4$289.00
Push on F Connector...1$0.79
ROHN 45G 55G...1$745.00
Power Passing...1$4.95
8' Foot X 1...1$27.95
DC Voltage...2$1.95
ROHN Universal...1$695.00
EZ60A 620 Steel...2$82.95
ROHN 45G/55G...3$558.00
Rohn RSL Tower...12$156.00
30 Foot Telescopic...2$206.00
Non-Penetrating...2$24.95
ROHN 25G Tower...3$97.00
Portable 3...2$27.95
FAM-12HR 12...25$2.45
Rohn Universal...1$49.00
5' Foot X 1...3$16.00
ROHN 25G 45G...2$210.00
ROHN 25G Tower...1$79.00
ROHN Lightning...12$145.00
ROHN 55G Tower...1$1,350.00
Thomas & Betts...1$2.60
Thomas and...1$4.90
PPC AquaTight...1$2.95
ROHN 25G Tower...1$7.95
HOLLAND 20...1$2.65
RG6 Underground...1$62.00
ROHN 45G 20...2$915.00
ROHN D1130...1$379.00
Rohn RSL Tower...13$345.00
ROHN 65G Adjustabl...1$745.00
24 inch Telescopic...2$34.75
#12 Solid Copper...1$24.95
PLA1000 F Connecto...1$49.95
RCA Male to...1$0.99
ROHN 25G Tower...2$101.00
ROHN Lightning...2$69.00
RG6 Underground...1$68.00
Cat6 UTP 550...1$1.30
LNS5000 Big...2$67.95
ROHN 25G Top...1$298.00
ROHN 24 inch...1$48.00
12 dB 2 Port...1$2.89
Telescopic...10$120.00
53" X 2.00"...2$17.95
Telescopic...35$164.00
Thomas & Betts...1$1.50
PPC EX6 PLUS...2$0.24
ROHN Bolt Kit...1$14.95
DS-1111 S TV...1$12.95
ROHN 25G Complete...1$3,125.00
Holland G-F81F*...1$0.39
ROHN H20 Telescopi...5$75.00
EZ TM-30-U...1$112.00
Mastic Sealing...1$1.95
BNC Female...1$2.25
ROHN 65g Top...1$319.95
ROHN NPPK Non...1$469.95
40 Foot Telescopic...1$309.00
Single Port...2$0.95
Six Port Keystone...1$1.05
Non-Penetrating...2$115.00
EZ30 30" Single...1$17.95
RG6 Coaxial...3$3.95
618 Telescopic...1$134.00
618 Telescopic...1$10.95
Dual Port Coaxial...1$1.35
36 Inch Roof...1$49.00
ROHN 45G 55G...1$290.00
16 dB 2 Port...1$2.89
ROHN 25G Tower...1$146.00
24 dB 2 Port...1$2.89
ROHN 65G Tower...2$665.00
Thomas & Betts...1$1.50
HOLLAND 12...2$2.65
48" - 72" TELESCOP...1$93.00
ROHN RSL 90...1$6,232.00
BNC Male to...1$1.55
ROHN 65G 35...1$4,836.00
12 inch Deluxe...2$19.95
ROHN 55FK 40...1$8,200.00
ROHN 25G 20...1$540.00
Gripple 1/8"...1$6.25
ROHN Leg Mounted...1$165.00
ROHN 25G Tower...1$398.00
6 inch TV Antenna...2$10.82
TFC RG11-OR...1$225.00
20 Foot Telescopic...1$126.00
8-Way Vertical...1$9.95
ROHN 65G 10...2$1,908.00
RG11 RG7 RG6...1$12.95
HOLLAND HDA...1$189.95
HOLLAND 8-Way...1$9.95
3 Foot Tripod...1$31.50
ROHN 25G Tower...1$184.00
ROHN 25G Antenna...2$415.00
ROHN 25G 10...1$334.00
ROHN RSL 100...1$6,400.00
ROHN 65G Tower...1$425.00
Dual Port Coaxial...1$1.30
5' Foot by...1$14.50
27 dB 1 GHz...1$2.65
Goods Total895$379,685.16
View Cart Check out
Printer View Tell a Friend

RG7 Quad Shield CAT5E Aerial Cable 1000' CS

Price$359.95
Manufacturer CodeF7SSVV-APD
Stock Level: 1
Qty
AvailabilityUsually ships in 24 Hrs
ShippingCan ship Canada

Highlights

PVC Jacket
FLooded
(2)100% Foil Coverage
(1)40% Braid
(1)60% Braid
QUAD Shield!
5 pr. 22 AWG Telco
Integral 0.083 Messenger

Bulk Quantities Available Here!

CommScope F7SSVV-APD 1000' RG-7 Coaxial Cable -w- CAT5E Aerial Messengered
BONDED LAMINATED ALUMINUM TAPE, 60% BRAID, LAMINATED ALUMINUM TAPE, 40% BRAID, FLOODED for Weather, PVC JACKET... CommScope F7SSVV-APD is Commercial Grade for Aerial Combination Telco Broad-Band Distribution Systems. RG-7 Coaxial and 5 pair of 22 AWG Service Wire all in one Integral package with a Sturdy Messenger.

 


 

Note

SuperShield (Quad Shield) - Taking the Tri-Shield construction one step further, this construction adds an additional layer of shielding braid to provide the greatest strength, durability and immunity from network interference. Provides low attenuations for service drops greater than 150 feet in length. Quad Shield Provides Maximum Shielding Integrity in a Pliable Coaxial Drop Package. This is the same Commercial Grade Low Loss Cable your local Cable TV company uses to get from the Telephone Pole to your House. Our Customers use this in their MHP Hotel Motel SMATV Cable TV, Video Surveillance and Hi Speed Internet Systems to distribute around Larger Properties.

Specification Sheet






Rate this product.
Product isn't rated yet. Write a review.

This RG11 Cable Product is designed for Aerial Suspension and Usage. It Features an Integral Steel Messenger in Siamese Configuration with the Coaxial Cable Jacket. This integral messenger precludes the need of the coaxial cable itself being utilized as the structural component in the suspension of the cable in the Air, from point to point. Steel messenger is separated and stripped away from the coaxial cable at the point of termination, and terminated with a suspension clamp that will loop around a "J" Hook (or equivalent) or simply wrapped around a screw-in "P" Hook for the same purpose. RG11 (RG-11) is to 75 Ohm as RG213 or RG214 is to 50 Ohm cable. RG11 Cable featuring 60% Braided Shield is comprised of an Aluminum Foil bonded to the Foam Dialectric with Aluminum Braided Shield with 60% coverage. Quad Shield RG11 would denote alternating Aluminum Foil and Aluminum Braided Shield Layers, starting with the Bonded Foil Layer around the Foam Dialectric, with the best Quad Shield having 2 Layers of Braided Aluminum Shield, one of 60% and the 2nd at 40%. Tri-Shield RG11 will have 77% Braided Aluminum Shield Coverage Between 2 Layers of Aluminum Foil Shield, the 1st Foil Layer being Bonded to the Foam Dialectric. RG11 is the lowest loss Flexible Braided Shield Drop cable Commercially Manufactured for Satellite TV, TV Antenna and Cable TV usage. Use for distances over 150 feet or when every dB counts. For Cable with less loss than RG11, one would then have to avail themselves to Hardline Coaxial with a Single Solid Shield (typically Aluminum) that is pricey, but delivers commensurate Results for the Money. Most all RG11 Manufactured uses Aluminum Braided Shield, the difference of note being the amount of Aluminum Braid Coverage and the composition of the Center Conductor; Solid Copper vs. Copper Clad Steel. Copper Clad Steel will suffice in almost any utilization scenario, however most Satellite TV Operating companies will require Solid Copper Center Conductor to be used by their respective Sub-Contractor Installers for Maintainence and Warranty issues. This is due to the DC Voltage component being fed from the Receiver back to, and Powering the LNB(f)s mounted on the Satellite Dish. Unless the run is extremely long and the connectors applied are of dubious Quality, the DC Loop Resistance difference between Solid Bare Copper and Copper Clad Steel is negligible.