Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
225 FT RG11...15$99.00
100 FT RG11...12$55.00
ROHN 25G Thrust...1$78.00
75 FT RG11...10$45.00
18 inch Deluxe...1$26.95
618 Telescopic...1$134.00
125 FT RG11...7$59.00
ROHN 65G Anti...3$960.00
HOLLAND LA...1$11.95
ROHN 25G 40...5$865.00
30 inch Telescopic...10$24.95
EZ TM-50-5U...1$115.00
Six Port Keystone...3$1.05
ROHN 45G Tower...1$162.00
EZ NP-60-125...1$89.45
Complete Grounding...11$32.00
10' Foot X...1$36.00
EZ TM-40-U...1$139.95
ROHN 4 inch...20$39.00
4 inch W type...4$10.95
40 Foot Telescopic...1$240.00
12 inch Telescopic...20$23.50
ROHN 25G Tower...2$7.95
24 inch Deluxe...22$34.95
ROHN 65G 20...1$2,600.00
EZ32 Telescopic...8$14.95
5' Foot X 1...16$16.30
BNC Female...1$2.25
2.5" to 3.75"...1$14.50
EZ32A Telescopic...18$21.95
Dual Port Coaxial...1$1.35
ROHN H50 Telescopi...55$189.00
ROHN 25G Tower...1$298.00
ROHN 24 inch...13$88.00
EZ30 30" Single...1$17.95
Thomas & Betts...1$1.30
ROHN 45G/55G...1$558.00
ROHN 25G Anti...2$598.00
ROHN 25G Tower...1$985.00
ROHN Tower...2$38.00
ROHN H20 Telescopi...10$75.00
EZ19B Roof...2$18.08
ROHN 12 inch...21$84.00
ROHN Universal...11$70.38
ROHN 55G Tower...3$1,350.00
ROHN 18 inch...6$86.00
Telescopic...5$144.00
Telescopic...10$117.00
3/8 inch Heavy...1$2.50
18 inch Telescopic...17$28.40
Telescopic...65$164.00
36 Inch Roof...1$49.00
ROHN TUF TUG...1$325.00
Rohn RSL Tower...7$310.00
Rohn RSL Tower...16$1,540.00
ROHN RSL 100...14$6,090.00
Rohn RSL Tower...10$345.00
ROHN 8 inch...20$79.00
Rohn RSL Tower...7$1,150.00
Rohn RSL Tower...16$1,345.00
Rohn RSL Tower...14$3,710.00
ROHN 25G Tower...3$97.00
Rohn RSL Tower...10$196.00
50 FT RG11...11$35.00
Rohn RSL Tower...15$592.00
ROHN 25G Tower...2$1,985.00
ROHN 65G 30...1$4,395.00
50 Foot Telescopic...13$325.00
RASK12 Accessory...14$296.00
4 inch Heavy...4$11.95
ROHN TUF TUG...20$335.00
53" X 2.00"...2$17.95
Turnbuckle...1$3.05
ROHN 25G 20...3$540.00
EZ TM-50-U...14$164.00
21" J Pipe...3$19.95
FAM-3 dB In...1$2.25
TTRSL50 Safety...2$580.00
Rohn RSL Tower...13$60.50
ROHN GAS604...1$69.95
ROHN RSL 100...17$6,636.00
Rohn RSL Tower...10$625.00
EZ32C Telescopic...12$24.95
ROHN 25G Antenna...2$415.00
Rohn RSL RGKG...14$430.00
Rohn RSL Tower...10$372.00
EZ48 48" Single...3$32.95
ROHN 25G Assembly...1$186.00
ROHN 65G Tower...5$1,350.00
ROHN 65G 45...1$6,253.00
EZ46-3PO Pitch...4$1.90
Dual Port Coaxial...1$1.65
Rohn RSL Tower...12$58.00
ROHN 25G Tower...1$79.00
Rohn RSWGB...12$260.00
ASKA SB-4UL...1$1.50
ROHN 25G Tower...1$239.00
Thomas and...2$0.35
24 inch Telescopic...2$34.75
Rohn RSL Tower...8$156.00
TTRSL100 Safety...12$850.00
ROHN 65G Tower...1$665.00
BNC Male to...3$1.55
HOLLAND 16...1$2.65
ROHN RSL 100...1$6,400.00
Holland G-F81F*...3$0.39
50 Foot Telescopic...12$282.00
ROHN Lightning...11$145.00
16 dB 2 Port...1$2.89
ROHN 25G 10...2$334.00
ROHN 55G Tower...2$420.00
ROHN RSL TOWER...9$33.00
8' Foot X 1...1$27.00
ROHN 65G Tower...2$390.00
RG11 RG7 RG6...2$24.95
ROHN 25G 45G...2$210.00
12 inch Deluxe...1$19.95
Telescopic...5$120.00
27" - 42" FLAT...1$32.00
Non-Penetrating...1$24.95
24 dB 2 Port...3$2.89
Digital Broadband...1$29.95
ROHN 25G Tower...3$335.00
DS-3000 J Pipe...2$28.95
HOLLAND 2-Way...1$2.60
EZ46-3 Pitch...3$3.95
ROHN 25AG 45AG...2$49.00
PPC EX6XL PLUS...2$0.26
ROHN 25G Tower...1$289.00
IN WALL BOX...1$91.00
HOLLAND 2-Way...2$2.60
ROHN 25G Accessory...2$74.00
ROHN 65G Section...1$84.95
10' Foot X...1$27.95
Butyl Weather...1$3.20
57" Inch X...4$18.95
ROHN 45G 40...1$1,605.00
ROHN 45GSR...1$1,872.00
1/4 inch Heavy...2$1.15
ROHN 25G Tower...1$184.00
ROHN H40 Telescopi...10$163.00
Protective...2$24.95
HOLLAND HFS...2$2.50
EZ TM-20-U...2$83.00
EZ60 620 Plastic...2$7.95
RG11 Quad Shield...20$154.95
5' Foot X 1...2$16.00
ROHN 45G 10...1$570.00
ROHN 25G 10...1$156.00
ROHN Bolt Kit...1$7.50
HOLLAND 3-Way...1$3.60
ROHN 25G 60...2$1,780.00
ROHN NPPK Non...1$469.95
ROHN 25G Tower...1$290.00
ROHN 24 inch...1$48.00
Holland TSTL...1$24.95
ROHN 65G Tower...2$425.00
1/2 inch Round...1$7.95
27” – 42”...1$110.00
Power Passing...1$4.95
Concrete Base...1$14.95
Non-Penetrating...1$115.00
EZ47-S3 2.5"...1$1.95
RG6 Coaxial...1$4.95
ROHN 65G Tower...1$780.00
27 dB 2 Port...1$2.89
ROHN 55G Tower...2$298.00
ROHN 65G 20...2$3,582.00
3/16" Extra...1$179.95
RG11 Quad Shield...1$310.00
3 inch HDG...1$13.95
HOLLAND 12...1$2.65
ROHN Lightning...1$69.00
PPC EX6 PLUS...1$0.24
ROHN 25G 35...1$897.00
12 dB 2 Port...1$2.89
ROHN 65G 35...1$4,836.00
ROHN 45G 55G...1$290.00
HOLLAND 8-Way...1$9.95
#12 Solid Copper...1$24.95
ROHN 45G Self...1$595.00
8 inch Deluxe...1$16.95
ROHN 65G 10...1$1,250.00
ROHN 25G Tower...1$101.00
RG6 Coaxial...1$3.95
Commscope RG11...1$230.00
ROHN 65G 10...1$2,794.00
ROHN 25G Tower...1$168.00
Frequency Agile...1$27.95
DS-1111 S TV...1$12.95
ROHN 25G Tower...1$358.00
ROHN 65G 30...1$3,406.00
Wide Band Satellit...1$8.95
In-Line Cable...1$32.95
ASKA GB-5UL...1$4.95
30 Foot Telescopic...1$166.00
10' Foot X...2$28.90
ROHN 65G Adjustabl...1$745.00
3/8TBE&J Turnbuckl...2$10.95
BNC Male to...1$1.90
DC Voltage...1$1.95
Mastic Sealing...1$1.95
ROHN 25G Tower...3$260.00
Thomas & Betts...1$14.95
ROHN 25G Tower...1$369.00
ROHN 45GSR...1$640.00
Thomas and...1$4.90
PPC AquaTight...1$2.95
8' Foot X 1...1$27.95
ROHN 65G 10...1$1,908.00
20 Foot Telescopic...1$126.00
Goods Total1006$513,532.51
View Cart Check out

ROHN 45G Towers

ROHN Tower Accessories

Original OEM Plates, Brackets, Bearings, Shelves, Hardware Mounts and other Accessories

45G Brackets & Mounts

Original OEM Brackets, Mounts and Accessories

ROHN Tower Sections

Middle, Top Cap, Solid Rail, Base and Specialty Tower Sections to Build a ROHN Tower Installation

ROHN Self Supporting Towers

ROHN G Series are available as self-supporting Pre-Engineered tower Kits.

ROHN Bracketed Towers

The ROHN Tower can be installed onto buildings using two brackets along the height of the Structure.

ROHN Guyed Towers

Pre-Engineered Tower Kits
TIA/EIA-222-F
TIA/EIA-222-G
Max Wind 70 to 130 MPH
ROHN 45G Towers, Sections, Parts and Accessories

The Rohn 45G Series Multipurpose Tower

Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the 45G tower. All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance.

Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a substitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 45G Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.

 


 

 

 

ROHN Complete Tower ID Nomenclature

 

DESIGN NOTES:

  1. Tower designs are in accordance with ANSI/TIA-222-F-1996 and ANSI/TIA-222-G-2005, Class I Structures.
  2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain.
  3. Designs assume one 1/2" and one 7/8" diameter lines on each tower face.
  4. Anchor radius is from tower base to intersection of anchor rod with ground.
  5. Tower designs and guy chord lengths shown are based on level ground. Initial tensions for guys in pounds at 60º Fahrenheit are shown in ( ).
  6. Antenna and mounts are assumed symmetrically placed at the tower top.

PARTS LIST NOTES:

  1. Items listed are required for complete (ground) guyed towers. Base and anchor details will be required for installation on roofs or for sites located on unusual terrains and wind loading criteria, for all roof type installations.
  2.  Standard guys provided with each standard tower include an additional 6% length.
  3. Anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.
  4. Installation information and a safety package (P/N: ACWS) are included with each tower.

Rohn 45G Part Specification Sheets & Rohn 45G Buyers Guides

Guides and specification sheets are found on every products specifications tab. For a complete list of these guides organized alphabetically by manufacturer part number/code, visit the detailed information and Specifications page. These documents should answer most of the questions you may have on the Rohn 45G product line

ROHN 45G Buyers Guide

 

ROHN 45G Buyers Guide

 

Workhorse of America's Communications

 

ROHN Tower series is the Workhorse of America's Communications needs large or small. People, institutions, governments and local businesses all use and trust our products every day. These products are used by agencies and industries like:

  • The Space Program
  • The Olympics
  • TV, AM & FM Broadcasting Stations
  • Terrestrial Microwave
  • Business-Band Radio
  • HAM Radio Operators
  • Off-Air Antenna
  • and DTV
  •  

Bringing reception to fringe areas outside the Suburban Broadcast Area. Plus everything is made right here in America. ROHN fabricates their towers from the highest quality steel. While maintaining mill certification on the raw materials they receive so they can verify the material composition of each structural member. With a focus on quality, their fabrication facility has been awarded Certification by the American Institute of Steel Construction and the Canadian Welding Bureau. Plus the City of Los Angeles, CA and Clark County, NV they are a certified fabricator. The Rohn facility and it's staff can produce a superior grade tower and supporting hardware that will meet your standards and weather the test of time.

ROHN Towers, Accessories and their Construction/Assembly Assistance are also available just contact us at 877-660-0974 at anytime for assistance.


GUIDELINES FOR THE

PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections