Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
Telescopic...95$164.00
EZ32A Telescopic...33$21.95
ROHN 12 inch...33$84.00
EZ32C Telescopic...40$24.95
3 inch wall...7$12.95
EZ32 Telescopic...28$14.95
ROHN 4 inch...38$39.00
Single Port...3$0.95
4 inch Heavy...44$11.95
Rohn RSL RGKG...23$430.00
50 Foot Telescopic...27$282.00
30 inch Telescopic...43$24.95
Rohn RSL Tower...33$156.00
Non-Penetrating...3$115.00
Rohn RSL Tower...25$592.00
Complete Grounding...28$32.00
EZ60 620 Plastic...1$7.95
5' Foot X 1...22$16.30
18 inch Telescopic...35$28.40
BNC Male to...4$1.55
50 Foot Telescopic...31$325.00
12 inch Telescopic...21$23.50
Rohn RSL Tower...25$196.00
ROHN Universal...33$70.38
Rohn RSL Tower...18$310.00
EZ19B Roof...9$18.08
Rohn RSL Tower...13$1,540.00
ROHN RSL 100...20$6,636.00
75 Ohm F Port...125$0.45
ROHN H50 Telescopi...160$189.00
Rohn RSL Tower...21$58.00
EZ46-3 Pitch...8$3.95
HOLLAND LA...5$11.95
HOLLAND 8-Way...2$9.95
TTRSL100 Safety...26$850.00
ROHN Lightning...31$145.00
ROHN 24 inch...31$88.00
4 inch W type...5$10.95
ROHN 25G Tower...1$166.00
ROHN TUF TUG...19$335.00
HOLLAND 6 dB...3$2.65
EZ DM 166-2...1$22.00
Mastic Sealing...2$1.95
ROHN 25G Accessory...3$74.00
21" J Pipe...1$19.95
50 FT RG11...18$35.00
ROHN 8 inch...20$79.00
225 FT RG11...23$99.00
1/8" Down...3$0.95
ROHN 18 inch...43$86.00
Rohn RSL Tower...23$3,710.00
ROHN 55G Tower...3$332.00
HOLLAND HFS...3$2.50
3 Foot Tripod...1$28.60
Rohn RSL Tower...10$372.00
ROHN RSL TOWER...19$33.00
10' Foot X...1$27.95
ROHN Lightning...4$69.00
Rohn RSL Tower...1$660.00
Rohn RSWGB...19$260.00
Protective...4$24.95
ROHN 25G Antenna...11$415.00
24 inch Deluxe...17$34.95
EZ TM-50-U...25$164.00
HOLLAND 9 dB...4$2.65
HOLLAND 16...2$2.65
20 Foot Telescopic...2$126.00
J Pipe Adapter...1$9.95
ROHN Universal...1$695.00
618 Telescopic...2$134.00
Rohn RSL Tower...22$60.50
Rohn RSL Tower...20$1,345.00
75 FT RG11...20$45.00
DC Voltage...5$1.95
ROHN 25G Tower...2$260.00
RG11 RG7 RG6...4$12.95
#12 Solid Copper...1$24.95
EZ46-3PO Pitch...12$1.90
Rohn RSL Tower...27$345.00
Rohn RSL Tower...11$1,150.00
Non-Penetrating...4$131.00
ROHN RSL 100...29$6,090.00
ROHN 55G Tower...4$420.00
LNS5000 Big...2$67.95
RASK12 Accessory...25$296.00
125 FT RG11...16$59.00
ROHN 55FK 40...1$8,200.00
EZ TS-50 Free...3$69.95
ROHN 25G Tower...4$101.00
Rohn RSL Tower...19$625.00
30 Foot Telescopic...5$166.00
ROHN 65G 40...1$5,090.00
ROHN 25G Tower...1$325.00
53" X 2.00"...14$17.95
ROHN BGK2G...3$89.00
ROHN 12 inch...1$45.00
Telescopic...10$117.00
Six Port Keystone...1$1.05
ASKA GB-5UL...1$4.95
ROHN 65G 20...2$1,668.00
ROHN GAS604...2$69.95
Dual Port Coaxial...2$1.30
RG6 Underground...1$34.00
RG6 Underground...2$38.00
ROHN 25G 45G...8$210.00
RG11 RG7 RG6...2$24.95
24 dB 2 Port...1$2.89
24 inch Telescopic...9$34.75
ROHN 65G Tower...2$665.00
ROHNJACK G...3$329.00
Non-Penetrating...3$24.95
ROHN 65G Tower...4$1,350.00
RCA Female...1$1.10
Telescopic...5$144.00
16 dB 2 Port...1$2.89
RG6 Coaxial...4$4.95
100 FT RG11...21$55.00
24 dB 1 GHz...3$2.65
ROHN 45G Tower...1$425.00
57" Inch X...2$18.95
EZ TM-30-U...5$112.00
BNC Female...2$2.25
ROHN TUF TUG...1$325.00
ROHN Bolt Kit...6$7.50
EZ TM-40-U...1$139.95
PPC EX6 PLUS...1$0.24
27 dB 1 GHz...2$2.65
Digital Broadband...1$29.95
ROHN 25G Tower...5$97.00
1/4 inch Heavy...1$1.15
ROHN 55G Tower...2$778.50
ROHN 25G Tower...1$110.00
Channel Master...4$1.40
FAM-12HR 12...25$2.45
Push on F Connector...4$0.79
ROHN 65g Top...2$319.95
10' Foot X...1$36.00
HOLLAND 2-Way...3$2.60
RG6 RG59 RG58...4$8.95
ROHN 25G Tower...2$205.00
ROHN 65G Adjustabl...2$745.00
Heavy Duty...1$54.95
Holland HPF...6$2.45
ROHN 55G Tower...7$298.00
ROHN 25G Top...5$298.00
ROHN 45G/55G...2$558.00
Turnbuckle...4$3.05
PLA1000 F Connecto...2$49.95
ROHN 55G Tower...1$1,478.00
ROHN Tripod...1$284.00
EZ DM 166-2...1$17.95
ROHN 45G Assembly...1$290.00
RG6 Coaxial...2$3.95
ROHN 65G 30...2$3,406.00
ROHN 8 inch...3$47.00
EZ TM-20-U...2$83.00
ROHN 25G 10...7$156.00
27 dB 2 Port...2$2.89
EZ30 30" Single...3$17.95
"Y" Style Chimney...1$23.50
EZ60A 620 Steel...2$82.95
Wide Band Satellit...1$8.95
3 dB Power...3$3.65
ROHN 65G Tower...1$390.00
Dual Port Coaxial...1$1.65
Broadband Digital...3$26.95
ROHN 6 inch...2$39.00
RG6 Coaxial...1$12.95
ROHN 25G Tower...3$1,985.00
Telescopic...10$78.00
16 AWG 4 Conductor...1$187.00
ROHN 45G 55G...1$156.00
DS-3000 J Pipe...2$28.95
5' Foot X 1...6$16.00
ROHN Leg Mounted...1$165.00
HOLLAND 12...3$2.65
ROHN 45G 40...3$1,605.00
30 Foot Telescopic...3$206.00
EZ48 48" Single...1$32.95
TTRSL50 Safety...1$580.00
5 Foot Tri-Mount...1$42.00
3 Foot Tripod...1$31.50
PPC Single...3$1.25
Adjustable...4$8.95
Commscope RG11...2$230.00
ROHN 45G Top...1$338.00
40 Foot Telescopic...1$240.00
ROHN 25G Tower...2$7.95
HOLLAND 8-Way...1$9.95
4 inch TV Antenna...3$12.00
8' Foot X 1...2$27.95
18 inch Deluxe...2$26.95
ROHN 45GSR...1$1,800.00
ROHN 25G Tower...2$298.00
Holland Electronic...2$2.95
3/8 X 4 Foot...3$16.00
Dual Port Coaxial...3$1.35
6 inch TV Antenna...3$10.82
Thomas & Betts...1$14.95
Universal Down...1$29.95
ROHN 65G 45...1$6,253.00
ROHN 25G Tower...3$335.00
ROHN 45G Tower...1$1,100.00
ROHN 45G 35...1$1,715.00
Protective...2$84.00
ROHN 65G Section...2$84.95
ROHN 45GSR...1$1,150.00
BNC Male to...2$1.55
10 Foot Tri-Mount...1$59.95
ROHN 55G 20...2$1,405.00
HOLLAND 20...1$2.65
Holland G-F81F*...2$0.39
ROHN 55G 40...2$2,005.00
Rohn Universal...2$49.00
Heavy Duty...1$29.95
Holland G-F811...1$0.29
30 dB 1 GHz...2$2.65
ROHN RSL 100...2$6,400.00
ROHN H20 Telescopi...5$75.00
ROHN 24 inch...1$48.00
RG6 Underground...1$68.00
ROHN Tower...2$38.00
ROHN 45G 55G...2$745.00
ROHN 65G 20...1$2,600.00
500 FT RG11...1$134.95
Dual Side Arm...2$159.95
ROHN 65G Tower...1$734.00
5 Foot Heavy...1$79.95
ROHN 45G Complete...1$17,380.00
ROHN 25G 45G...2$318.00
ROHN 25G 30...1$694.00
Thomas and...1$4.90
FAM-10HR 10...25$2.45
Thomas and...2$0.35
ROHN 45G 55G...2$290.00
Coaxial Cable...2$1.95
8 inch Deluxe...1$16.95
HOLLAND 2-Way...1$1.60
ROHN 45GSR...1$640.00
ROHN 25G Tower...1$79.00
Telescopic...5$120.00
4 inch W type...1$10.95
HOLLAND HDA...1$189.95
PPC TR75-SS...25$0.49
1 HDMI + 2...1$16.00
5' Foot by...1$14.50
RG6 Underground...1$62.00
ROHN NPPK Non...3$469.95
Gripple 1/8"...1$6.25
APICA AP-RCA...1$1.39
ROHN 25G Universal...1$128.00
Commscope 2...1$1.25
ROHN 25G Tower...3$369.00
ROHN 55G Tower...1$1,350.00
ROHN 25G Tower...1$358.00
Non-Penetrating...1$99.56
PPC EX6WS AquaTigh...1$0.28
9 dB 2 Port...3$2.89
ROHN 25G 45G...1$316.00
Thomas & Betts...1$2.60
12 inch Deluxe...1$19.95
3/16 inch Big...1$8.95
Holland TSTL...1$24.95
ROHN 45G Tower...1$204.00
ROHN 25G 10...1$334.00
5/8 X 8 Foot...1$24.95
PPC AquaTight...1$2.20
12 dB 2 Port...1$2.89
3 inch HDG...1$13.95
PPC AquaTight...1$2.95
ROHN 65G 10...2$1,695.00
Rohn RSL Tower...1$715.00
LNS5010 Black...2$39.95
Dual Port Keystone...1$1.15
ROHN 18 inch...3$47.00
HOLLAND Horz...1$4.95
ROHN 25G Tower...1$478.00
ROHN 25G 40...1$865.00
ROHN 3 Foot...1$389.95
Locking Terminator...1$16.70
ROHN 65G 20...1$4,706.00
ROHN 45AG Tower...1$14.95
Heavy Duty...1$39.95
EZ TM-50-5U...1$115.00
ROHN RTL 140...1$0.00
Universal Tower...1$146.00
Goods Total2172$820,793.49
View Cart Check out
Printer View Tell a Friend

ROHN 45GSR Complete 320 Foot 110 MPH Guyed Tower R-45GSR110R320

Price$41,554.00
Manufacturer Code45GSR110R320
Qty
AvailabilityCall to Order or Request Quote
ShippingCan ship only within USA

Highlights

Hot Dip Galvanized
Flanged Bolted Joints
Zig-Zag Rod Bracing
1-1/4" Solid Steel Tubing Side Rails
16-3/4" Equalateral
Triangular Design
Can be used in:
Guyed Config

Bulk Quantities Available Here!

ROHN 45GSR Complete 320 Foot 110 MPH (REV. G) Guyed Tower
This Product Order Supplies the Following BOM (Less Foundation and Installation) in accordance for use as a 320 Foot ROHN 45GSR Tower with EPA's (Effective Projected Area) Ratings for 110 MPH (REV. G). Refer to Larger Image for EPA Information.

(15) 45GSR20
(1) 45GSR20L82
(1) APL4A
(1) 45GSRSB
(7) GA45GD
(4225') 1/4EHS
(1200') 142265
(1300') 142261
(36) BG2144
(6) BG2146
(6) BG2147
(36) 3/8THH
(6) 7/16THH
(6) 1/2THH
(24) 5/8TBE&J
(6) TBSAFETY
(6) GAC5655TOP
(2) AGK1GGX
(3) BGK3GGX
(6) CPC1/1.25
(3) 5/8S

This 45GSR Tower is to be used in a Guyed Configuration according to Specifications in the ROHN Catalog. As a Guyed Structure, a 110 MPH rated Tower can rise to a maximum of 350 feet. Refer to ROHN catalog for Foundation and Grounding Detail Information. Consult ROHN Catalog Links at Footer Section at Bottom of Page for more ROHN 45GSR Tower Details.

Specification Sheet
buyers guide
wind speed rating
110
Rate this product.
Product isn't rated yet. Write a review.

TIA/EIA-222-G, the national standard´s seventh revision for Steel Antenna Towers and Antenna Supporting Structures, became effective January 1, 2006. REV. F wind loading is calculated according to the Fastest-Mile Wind Speed for the structure´s location as recorded from the 1-in-50-year wind speeds encountered at that location that were constant over a distance of one mile. REV. G requires that wind loading be calculated according to the three-second-gust wind speed, allowing the tower´s design to accommodate instantaneous loads. Loadings will be determined by specific local county criteria from wind, ice, and seismic maps.
Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the 45GSR tower. All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance.

 Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a susbstitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 45GSR Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.

 


 

ROHN Complete Tower ID Nomenclature

DESIGN NOTES:

1. Tower designs are in accordance with ANSI/TIA-222-G, Class I Structures, Topographic Category 1.

2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites

located on unusual terrain.

3. Designs assume two 7/8" diameter lines on each tower face.

4. Anchor radius is from tower base to intersection of anchor rod with ground.

5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit.

6. Antenna and mounts are assumed symmetrically placed at the tower top.

 

PARTS LIST NOTES:

1. Items listed are required for complete guyed towers.

2. Base and anchor foundations listed refer to standard foundation designations.

3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.

4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.

5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.

6. Parts lists are subject to change based on availability or revised design criteria.

 


 

ROHN 45GSR Buyers Guide



ROHN 45GSR Buyers Guide


Get Adobe Reader



This Buyers Guide will answer many questions you may have on this Product Line.

ROHN Tower series is the Workhorse of America's Large and Small Communications needs; from Governments, Institutions, Space Program, Olympics, TV AM FM Broadcast, Terrestrial Microwave to Business-Band Radio, HAM Radio Operators, to Off-Air Antenna TV and DTV Reception in Fringe areas outside the Surburban Broadcast Area. ROHN fabricates their towers from the highest quality steel. They maintain mill certification on the raw materials they receive to verify the material composition of each structural member. With a focus on quality, their fabrication facility has been awarded Certification by the American Institute of Steel Construction and the Canadian Welding Bureau. They have also been approved by the City of Los Angeles, CA and Clark County, NV as a certified fabricator. They are confident that their facility and staff can produce superior grade towers and poles that will meet your standards and weather the test of time. ROHN Towers, Accessories and their Construction/Assembly Assistance are also available via 3StarInc.com... Call 877-660-0974 at anytime for assistance.


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections