Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
225 FT RG11...10$99.00
100 FT RG11...11$55.00
ROHN 25G Thrust...1$78.00
75 FT RG11...9$45.00
18 inch Deluxe...1$26.95
618 Telescopic...1$134.00
125 FT RG11...6$59.00
ROHN 65G Anti...3$960.00
HOLLAND LA...1$11.95
ROHN 25G 40...4$865.00
30 inch Telescopic...7$24.95
EZ TM-50-5U...1$115.00
Six Port Keystone...3$1.05
ROHN 45G Tower...1$162.00
EZ NP-60-125...1$89.45
Complete Grounding...6$32.00
10' Foot X...1$36.00
EZ TM-40-U...1$139.95
ROHN 4 inch...14$39.00
4 inch W type...4$10.95
40 Foot Telescopic...1$240.00
12 inch Telescopic...16$23.50
ROHN 25G Tower...2$7.95
24 inch Deluxe...16$34.95
ROHN 65G 20...1$2,600.00
EZ32 Telescopic...3$14.95
5' Foot X 1...11$16.30
BNC Female...1$2.25
2.5" to 3.75"...1$14.50
EZ32A Telescopic...11$21.95
Dual Port Coaxial...1$1.35
ROHN H50 Telescopi...25$189.00
ROHN 25G Tower...1$298.00
ROHN 24 inch...10$88.00
EZ30 30" Single...1$17.95
Thomas & Betts...1$1.30
ROHN 45G/55G...1$558.00
ROHN 25G Anti...1$598.00
ROHN 25G Tower...1$985.00
ROHN Tower...2$38.00
ROHN H20 Telescopi...10$75.00
EZ19B Roof...2$18.08
ROHN 12 inch...17$84.00
ROHN Universal...8$70.38
ROHN 55G Tower...1$1,350.00
ROHN 18 inch...4$86.00
Telescopic...5$144.00
Telescopic...10$117.00
3/8 inch Heavy...1$2.50
18 inch Telescopic...13$28.40
Telescopic...50$164.00
36 Inch Roof...1$49.00
ROHN TUF TUG...1$325.00
Rohn RSL Tower...5$310.00
Rohn RSL Tower...12$1,540.00
ROHN RSL 100...11$6,090.00
Rohn RSL Tower...8$345.00
ROHN 8 inch...13$79.00
Rohn RSL Tower...5$1,150.00
Rohn RSL Tower...11$1,345.00
Rohn RSL Tower...10$3,710.00
ROHN 25G Tower...2$97.00
Rohn RSL Tower...9$196.00
50 FT RG11...10$35.00
Rohn RSL Tower...9$592.00
ROHN 25G Tower...1$1,985.00
ROHN 65G 30...1$4,395.00
50 Foot Telescopic...8$325.00
RASK12 Accessory...11$296.00
4 inch Heavy...3$11.95
ROHN TUF TUG...12$335.00
53" X 2.00"...2$17.95
Turnbuckle...1$3.05
ROHN 25G 20...1$540.00
EZ TM-50-U...10$164.00
21" J Pipe...2$19.95
FAM-3 dB In...1$2.25
TTRSL50 Safety...2$580.00
Rohn RSL Tower...9$60.50
ROHN GAS604...1$69.95
ROHN RSL 100...11$6,636.00
Rohn RSL Tower...8$625.00
EZ32C Telescopic...8$24.95
ROHN 25G Antenna...2$415.00
Rohn RSL RGKG...11$430.00
Rohn RSL Tower...6$372.00
EZ48 48" Single...2$32.95
ROHN 25G Assembly...1$186.00
ROHN 65G Tower...4$1,350.00
ROHN 65G 45...1$6,253.00
EZ46-3PO Pitch...3$1.90
Dual Port Coaxial...1$1.65
Rohn RSL Tower...6$58.00
ROHN 25G Tower...1$79.00
Rohn RSWGB...8$260.00
ASKA SB-4UL...1$1.50
ROHN 25G Tower...1$239.00
Thomas and...1$0.35
24 inch Telescopic...2$34.75
Rohn RSL Tower...5$156.00
TTRSL100 Safety...10$850.00
ROHN 65G Tower...1$665.00
BNC Male to...3$1.55
HOLLAND 16...1$2.65
ROHN RSL 100...1$6,400.00
Holland G-F81F*...2$0.39
50 Foot Telescopic...9$282.00
ROHN Lightning...8$145.00
16 dB 2 Port...1$2.89
ROHN 25G 10...2$334.00
ROHN 55G Tower...2$420.00
ROHN RSL TOWER...6$33.00
8' Foot X 1...1$27.00
ROHN 65G Tower...2$390.00
RG11 RG7 RG6...1$24.95
ROHN 25G 45G...2$210.00
12 inch Deluxe...1$19.95
Telescopic...5$120.00
27" - 42" FLAT...1$32.00
Non-Penetrating...1$24.95
24 dB 2 Port...3$2.89
Digital Broadband...1$29.95
ROHN 25G Tower...2$335.00
DS-3000 J Pipe...2$28.95
HOLLAND 2-Way...1$2.60
EZ46-3 Pitch...2$3.95
ROHN 25AG 45AG...2$49.00
PPC EX6XL PLUS...2$0.26
ROHN 25G Tower...1$289.00
IN WALL BOX...1$91.00
HOLLAND 2-Way...1$2.60
ROHN 25G Accessory...2$74.00
ROHN 65G Section...1$84.95
10' Foot X...1$27.95
Butyl Weather...1$3.20
57" Inch X...2$18.95
ROHN 45G 40...1$1,605.00
ROHN 45GSR...1$1,872.00
1/4 inch Heavy...1$1.15
ROHN 25G Tower...1$184.00
ROHN H40 Telescopi...5$163.00
Protective...2$24.95
HOLLAND HFS...2$2.50
EZ TM-20-U...1$83.00
EZ60 620 Plastic...1$7.95
RG11 Quad Shield...20$154.95
5' Foot X 1...2$16.00
ROHN 45G 10...1$570.00
ROHN 25G 10...1$156.00
ROHN Bolt Kit...1$7.50
HOLLAND 3-Way...1$3.60
ROHN 25G 60...1$1,780.00
ROHN NPPK Non...1$469.95
ROHN 25G Tower...1$290.00
ROHN 24 inch...1$48.00
Holland TSTL...1$24.95
ROHN 65G Tower...1$425.00
1/2 inch Round...1$7.95
27” – 42”...1$110.00
Power Passing...1$4.95
Concrete Base...1$14.95
Non-Penetrating...1$115.00
EZ47-S3 2.5"...1$1.95
RG6 Coaxial...1$4.95
ROHN 65G Tower...1$780.00
27 dB 2 Port...1$2.89
ROHN 55G Tower...2$298.00
ROHN 65G 20...2$3,582.00
3/16" Extra...1$179.95
RG11 Quad Shield...1$310.00
3 inch HDG...1$13.95
HOLLAND 12...1$2.65
ROHN Lightning...1$69.00
PPC EX6 PLUS...1$0.24
ROHN 25G 35...1$897.00
12 dB 2 Port...1$2.89
Goods Total722$362,356.73
View Cart Check out

ROHN 45GSR Towers

ROHN Tower Accessories
Original OEM Plates, Brackets,
Bearings, Shelves, Hardware
Mounts and other Accessories
ROHN Tower Sections
Middle, Top Cap, Solid Rail, Base
and Specialty Tower Sections to
Build a ROHN Tower Installation

ROHN Guyed Towers
Pre-Engineered Tower Kits
TIA/EIA-222-F & TIA/EIA-222-G
Wind Speeds 70 to 130 MPH

ROHN Self Supporting Towers
ROHN G Series are available as 
self-supporting tower in Kits that
are Specifically Pre-Engineered

ROHN 45GSR Meteorological Towers
ROHN Meteorological Tower Kits
TIA/EIA-222-G Wind to 110 MPH
Structure Class II / Exposure C
ROHN 45GSR Towers, Sections, Parts and Accessories

Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the 45GSR tower. All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance.

 Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a susbstitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 45GSR Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.

 


 

ROHN Complete Tower ID Nomenclature

DESIGN NOTES:

1. Tower designs are in accordance with ANSI/TIA-222-G, Class I Structures, Topographic Category 1.

2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites

located on unusual terrain.

3. Designs assume two 7/8" diameter lines on each tower face.

4. Anchor radius is from tower base to intersection of anchor rod with ground.

5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit.

6. Antenna and mounts are assumed symmetrically placed at the tower top.

 

PARTS LIST NOTES:

1. Items listed are required for complete guyed towers.

2. Base and anchor foundations listed refer to standard foundation designations.

3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.

4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.

5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.

6. Parts lists are subject to change based on availability or revised design criteria.

 


 

ROHN 45GSR Buyers Guide



ROHN 45GSR Buyers Guide


Get Adobe Reader



This Buyers Guide will answer many questions you may have on this Product Line.

ROHN Tower series is the Workhorse of America's Large and Small Communications needs; from Governments, Institutions, Space Program, Olympics, TV AM FM Broadcast, Terrestrial Microwave to Business-Band Radio, HAM Radio Operators, to Off-Air Antenna TV and DTV Reception in Fringe areas outside the Surburban Broadcast Area. ROHN fabricates their towers from the highest quality steel. They maintain mill certification on the raw materials they receive to verify the material composition of each structural member. With a focus on quality, their fabrication facility has been awarded Certification by the American Institute of Steel Construction and the Canadian Welding Bureau. They have also been approved by the City of Los Angeles, CA and Clark County, NV as a certified fabricator. They are confident that their facility and staff can produce superior grade towers and poles that will meet your standards and weather the test of time. ROHN Towers, Accessories and their Construction/Assembly Assistance are also available via 3StarInc.com... Call 877-660-0974 at anytime for assistance.


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections