ROHN
Made in the USA!
The ROHN 55G90R400 400' foot 55G Guyed Tower Kit comes Complete and Pre-engineered as Specified in the ROHN Catalog for Use at the Rated Height, Antenna Load and Wind Speed indicated. This 55G90R400 Kit is comprised of the following BOM (Less Foundation and Installation) in accordance for use as a 400 Foot ROHN 55G Tower with EPA Ratings (Effective Projected Area) for 90 MPH (Rev. G) and 70 MPH (Rev. F).
This ROHN 55G Tower is to be used in a Guyed Configuration for Wireless Internet, Amateur and Business Radio, SCADA, DBS and Satellite Services, Cellular and Repeater, Smaller Microwave, Narrow Beamwidth Antenna or Broadcast Installations according to Specifications in the ROHN Catalog.
As a Guyed Structure, a 90 MPH Rated ROHN 55G Tower can rise to a Maximum of 400 Feet.
Click on the More Info and Specification Tabs above for all the Information You Need on this Product including EPA (Effective Projected Area wind load permissible of Antenna Surface Area in Square Feet), Foundation, Guying, Assembly and Grounding Detail Information.
This Item Ships LTL Freight ONLY!
EPA for Exposure B / Revision G = 26.1 (Sq. Ft.)
EPA for Exposure C / Revision G = 22.7 (Sq. Ft.)
EPA at ( 70 MPH) per Revision F = 19.2 (Sq. Ft.)
| BILL OF MATERIALS: 55G90R400 90/70 MPH RATED PRE-ENGINEERED KIT | ||
|---|---|---|
| QUANTITY | PART NUMBER | DESCRIPTION |
| 1 | APL55G | Top Beacon Plate for 55G |
| 40 | 55G | 10' Main Tower Section |
| 40 | 25JBK | Bolt Kit for 55G Tower Section |
| 1 | BPC55G | Standard Concrete Base Plate |
| 8 | GA55GD | Guy Wire Bracket Assembly |
| 1,600 ft | 5/16EHS | 5/16” Extra High Strength Strand |
| 4,700 ft | 1/4EHS | 1/4” Extra High Strength Strand |
| 2,075 ft | 3/16EHS | 3/16” Extra High Strength Strand |
| 24 | PLP-115 | Yellow Plastic Guard for Down Guys |
| 6 | BG2146 | 5/16" Big Grip Preform Dead-ends |
| 24 | BG2144 | 1/4" Big Grip Preform Dead-ends |
| 18 | BG2142 | 3/16" Big Grip Preform Dead-ends |
| 6 | 7/16THH | 7/16" Heavy Duty Thimble |
| 24 | 3/8THH | 3/8" Heavy Duty Thimble |
| 18 | 5/16THH | 5/16" Heavy Duty Thimble |
| 15 | 5/8TBE&J | 5/8" x 12" Turnbuckle Eye-to-Jaw |
| 9 | 1/2TBE&J | 1/2" x 12" Turnbuckle Eye-to-Jaw |
| 6 | TBSAFETY | Turnbuckle Safety Wire and Clamps Kit includes: (1) 14001 – 1/4” Galvanized Guy Clamp (1) 1/44GW15 – 1/4” x 15’ Guy Wire |
| 3 | GAC5655TOP | 120" Guy Anchor with 5 Hole Equalizer Plate |
| 3 | GAC3455TOP | 81" Guy Anchor with 5 Hole Equalizer Plate |
| 2 | AGK1GGX | Anchor Rod Ground Kit includes: (3) 15' of 7/16 EIP IWRC RRL (3) 5/8" x 10' Galvanized Ground Rod (AKA 6260) (3) 3/4” Clamp No. 8034 WB (AKA 340016) (3) CPC.5/.75 Anchor Rod Clamp |
| 3 | BGK2GGX | Tower Base Section Grounding Kit includes: (1) 15' of 7/16 EIP IWRC RRL (1) 5/8" x 10' Copper Clad Ground Rod (1) 3/4" Clamp Ground Rod Clamp (1) CPC1.5/2 Tower Section Rail Clamp |
| 3 | CPC1/1.25 | Anchor Rod Clamp |
| 3 | CPC.5/.75 | Anchor Rod Clamp |
| 1 | 3/4x12PP | Concrete Base Plate Pier Pin Insert |
| 1 | ASSEMBLY GUIDE | Printed Specification/Assembly Guide |
Guyed Towers are limited in Height due to the nature of Antenna and Ice loads versus the Cantilever Nature Of Wind against them, offset by the Downward force of all Downguy tensioned as specified, terminated to a properly embedded Anchor, the weight/size of the Foundation and the cohesive of the soil to prevent skid/pullout and all together to counter a Structural Failure or Tower tip-over moment, as well as the strength of the tower members to withstand these Forces against them. ROHN Tower Kits are designed based on assumptions made regarding Windspeed, EPA (Antenna Load), Ice Load, Transmission Cable Loads, Height, Standard Soil Conditions, Surrounding Environment and Duty (Exposure Categories).
The Pre-packaged Kits contain the parts called for based on this Stock Design. The Stock Design of these Kits does not account for the Variations of Historic Windspeed, Number of Antenna(e) Loading at Specific Height(s), Soil Engineering recommendations, Adjacent Structures, Communications Purpose, or Geo-Political Rules, Laws and Codes That will be Applicable to Your Project.
It is Recommended that you take the time to engage an local Engineer that has the expertise and available Information necessary to evaluate the Stock design for Applicability, and/or Fill Out the Tower Quote Data Sheet Form found by clicking the Specification Tab above and send to 3 Star Inc./ROHN for a review.
*Per Rev G requirements, any structure greater than 10' foot requires a climber safety device.
Understanding which Grounding Kits to use for what application can be a challenge. Again, REV. F and REV. G play a role in delineating the major differences between the kits and parts supplied with the Complete Tower Packages you purchase. As the approach to Grounding differs between the two, let's first understand which REV.# your Tower may be...
REV. F - All Self-Supporting Towers, all Bracketed Towers and those Guyed Tower Kits with a Part number containing a D between the windspeed and height designations ( ie. R-45G110D040) in the nominclature are REV. F classification and therefore will have these characteristics in common...
REV. F Tower Base Grounding - each Base Grounding Kit will come with material to bond one tower section rail to ground via a clamp, ten foot of solid copper wire and an eight foot ground rod. Depending on the Tower height and Base style, the Tower Kit may contain one, two or three of these Base Grounding Kits. For example; a ten foot Self-Supporting Tower Kit will come with one Base Rail Grounding Kit, the rest will come with two. A Bracketed Tower Kit likewise will come with the same number of Kits depending on Height. A Guyed Tower Kit will come with three of these Kits. A Tower with a Tapered Base Section will come with a Grounding Kit designed to attach via a Lug to one of the side panel plates on the section; rather than a Rail Clamp connection.
REV. F Tower Guy Grounding - each Tower Down Guy Grounding Kit will come with material to bond three Tower Down Guy Anchor locations via a Split Bolt clamp to each Down Guy Stranded Wire with 15 feet of Solid Copper wire to pass through all Split Bolt Bonds on its way to connect with one 8 foot Ground Rod.
REV. G - All Guyed Tower Kits with a a part number containing an R between the windspeed and height designations (ie. R-45G130R040) in the nomenclature are REV. G classification and will have these characteristics in common. The Base and Anchor Grounding Kits model number will end with a "GX"...
REV. G Tower Base Grounding - each Base Grounding Kit will come with material to bond one tower section rail to ground via a clamp, ten foot of solid copper wire and a ten foot ground rod. All Guyed Tower Kits will come with three of these Base Grounding Kits. Those Tower Kits with Tapered Bases will come with hardware to connect to that Base accordingly.
REV. G Tower Guy Grounding - each Tower Down Guy Grounding Kit will come with material to bond three Tower Down Guy Anchor locations via attachment to the Down Guy Anchor Rod itself with a Clamp, 15 feet of Braided Steel Wire Rope to a ten foot Ground Rod.
REV G GROUNDING REQUIREMENT FOR STRUCTURES
Rev G made signicant changes regarding the grounding requirements for structures. A prescriptive approach to grounding was used in Rev F where providing specic grounding leads and ground rods were considered adequate to protect a structure.
Rev G adopted a performance specication approach that requires providing a grounding system that will result in a maximum 10 ohm resistance to earth. Rev G also requires minimum ground lead and ground rod sizes that are greater than the Rev F prescriptive requirements.
Another change is that Rev G does not require specic grounding materials. Rev F required the use of galvanized ground rods with tinned copper leads. Rev G only requires that the leads and connections be compatible with the ground rods from a corrosion standpoint (i.e. minimize di-erence between metals connected).
Rev G does provide default grounding arrangements for various types of structures that are intended to meet the 10 ohm requirement for a wide variety of soil conditions. In accordance with Rev G, the actual resistance of a default grounding system must be veried based on site conditions. Additional ground rods or special grounding systems may be required.
It should be noted that the TIA-222 grounding requirements are meant to protect the structure and foundation from high fault currents. Other grounding requirements are often needed for the protection of antennas, radio equipment and other appurtenances.