Thomas & Betts TNB4003 Aluminum Dual Ground Block

Price$1.30
Manufacturer CodeTNB4003
Qty
AvailabilityUsually ships in 24 Hrs

Highlights

#17 to #8 Ground Connector

Bulk Quantities Available Here!

TnB TNB4003 Aluminum Dual Ground Lug
Appears on the DISH Network Approved List!

This dual ground lug is used as a double barrel ground lug for bolted connection to a frame or part.


This is what you want to use to Ground your Satellite, Cable TV or HDTV Antenna Coaxial Cable Outside before bringing the Signal Inside. This way, Lightning Strikes and Power Surges have an opportunity to arrest before reaching your TV and Entertainment Electronics. The grounding Block will convey this unwanted Electrical Energy to a Ground Rod via a Copper Ground Wire that you Install (not included). This Item Features a Hi Pressure Center Conductor Seizing Mechanism that Assures a Maintenance Free Connection for Longevity. Consult your Local Building Code and NEC for guidance to Properly Grounding your HD TV Antenna, Cable TV, WI-FI, Wireless Internet, Business Band, CB or Amateur Radio Antenna Installation.

Specification Sheet
grounding type
Ground Blocks

Structured Cable

Though Structured Cable Products and Home Network Wiring is Bundled Together for Economy in Space and Ease of Installation, the Component Cables and Wires should still be treated as Individual with the Systems to which they belong as compared to the Whole. No One System should be Sacrificed to serve the Needs of Another. When Preparing Terminations, Leave Plenty of Tail before Prep, and Plenty of Spare to Coil after. This will Serve Future Expansion Well. Most Manufacturers know the limitations of the Individual Wires and Cables their are Bundling, Make Sure you do too. It is Especially Important to Approach Installation as the Most Fragile of Components as the Major Consideration. Do not Force the Issue, If It doesn't fit, Be patient enough to Figure a Work-Around. A properly prepared Communications PVC Conduit route involves sweeps, not 90 Degree bends, and as few as possible. The size of the conduit should be 4 times that to be occupied. Install with MuleTape already inside for ease of pull-through. Do not under any circumstances collocate communications circuits with power. Even in Conduit, power circuits and routings should be crossed at 90 angles of intersect as to avoid field induction. If your routing has to be parallel, consider 2 feet to be minimum distance if either is shielded, 4 to 6 feet if not. Comm circuits should avoid flourescent lighting at all costs... The fields generated from the ballast transformer and even the bulb will wreak havoc on todays micro-circuits.

There are Panel Box Systems made for central inter-connection of Video, Telco, Internet and Intercom. Regardless of manufacture, they are pretty much standardized in the block-out of space inside, and the installation of the Modular blocks of Termination and patching. Again, AC power for the systems should remain outside the panel, with either the transformers plugged into the outlet and DC running through the bulhead inside the Panel, or the standard AC plug running through a bulk-head to the outlet outside the Panel.