Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
VMP Antenna...1$110.95
620 Steel Down...1$82.95
1/8CCF Forged...1$0.95
ROHN BPL45GSR...1$390.00
3 Foot Roof...1$54.00
ROHN H50 50'...5$225.00
Coaxial Cable...1$1.95
Goods Total11$1,765.80
View Cart Check out

Categories

Printer View Tell a Friend

3-Way Down Guy Wire Kit for 20 Foot Telescopic Antenna Mast H203WAYGUY

Price$126.00
Manufacturer CodeH203WAYGUY
Guy Wire ...:
Guy Anchor: View
Base Mount: View
Add a Mast :
Qty
AvailabilityUsually ships in 24 Hrs

Highlights

6 Strand/ 20GA Wire
30 inch Steel Anchors
"Gripple" Guy Wire Tension Grip
Mounts not included
Down Guy Kit for:
ROHN H20, Easy Up TM20

Bulk Quantities Available Here!

3 Star Inc H203WAYGUY 3-Way Down Guy Wire Kit for 20 Foot Telescopic Antenna Mast
This H203WAYGUY Kit is a 3-way Down Guy Wire and Anchor package to secure your ROHN H20 and Easy Up TM20 Telescopic Push Up Antenna Masts at 2 levels. Guy wire gauge, Anchor size and Base Mount are Selectable Options.
(Mast is not included)

Works with the following Telescopic Masts:

ROHN- H20
Easy Up- EZ TM-20, EZ TM-20-U-95
Channel Master- 1620, 1820

 

THE H203WAYGUY KIT INCLUDES THE FOLLOWING + OPTIONS
BILL OF MATERIALS: 20 Foot 3-Way Guy Wire & Anchor Kit
QUANTITY PART NUMBER DESCRIPTION
DOWN GUY WIRE SELECTION
200 FT (Includes) EZ 60 A 6 Strand 20 Gauge Guy Wire
200 FT (Optional) EZ 60 6 Strand 20 Gauge Guy Wire Plastic Coated
200 FT (Optional) 618 6 Strand 18 Gauge Guy Wire
DOWN GUY ANCHOR SELECTION
3 (Includes) EZ 30 30” by 1/2” DIA Screw Anchor w/ 3” Helix
3 (Optional) EZ 48 48” by 5/8” DIA Screw Anchor w/ 6” Helix
CLAMPS/GRIPPLES INCLUDED
6 (Includes) 61820GRPL Gripple for 20 and 18 Gauge Guy Wire used for
Termination and Tension Adjustment of Guy Wire
18 (Includes) 1/8CCF 1/8” Hot-Dipped Galvanized Cable Clamp
BASE PLATE MOUNT SELECTION
1 (Includes) EZ 32 Standard Baseplate
9" Sq. Plate/No Collar
Pier Pin Included
1 (Optional) EZ 32C Heavy-Duty Baseplate
9” Sq. Plate/ 6" Collar -w- (1) Set Screw
Accepts 2.25" OD Mast Pipe
Pier Pin Included
1 (Optional) EZ TS-50 Heavy-Duty Direct Ground Mount
9” Sq. Plate/18" Collar -w- (2) Set Screws
Accepts 2.25" OD Mast Pipe
18.75" Welded Drive-in Rod (Stake)
For Temporary Installations
TELESCOPIC MAST SELECTION
1 (Optional) EZ TM-20-U-95 UPS Shippable Telescopic Mast
Extends to 15 Feet ONLY

General Information

This 3-Way Guy Wire and Anchor Kit is for 20 Foot Telescopic Push Up Antenna Masts.
Includes the accessories needed to SECURELY affix a Ground Based Telescopic Mast at the (2) levels of Down Guys from Guy Rings.
(Guy Rings supplied on Your Mast)
The standard Baseplate given is solely used for GROUND Mounted Installations.
There are other Mounts Designed for Roof Installations.
Wall Brackets may add to Structural integrity but do Not Replace the need for Down Guys.
Manufacturers recommend that masts heights of 10 feet and higher above the uppermost bracket be guyed for Addition Wind Load Support. Bonding/Grounding should be made by affixment to Mast. Consult NEC and Applicable Local Code for further guidance
PLEASE CONTACT A STRUCTURAL ENGINEER or PROFESSIONAL before installing Premise attached Structure.
As with all masts, Guy Wire Support and Grounding are CRITICAL to Antenna Survival.

Note

Reference the Telescopic Mast ROHN Buyer’s Guide by Height to build or supplement your Telescopic Antenna Mast installation by clicking the Specification or More Info Tab above.
3-Way Down Guy Wire Kits are typically used for Ground-Based installations.
4-Way Down Guy Kits are typically used for Roof-Based installations.
Installations that are combination or hybrid and utilize substitution or additional structural components should be forwarded to and engaged by an Engineer qualified to make such decisions.

Installation Sheet
Telescopic Mast Install
Buyers Guide
ROHN Telescopic Mast

Understanding which Grounding Kits to use for what application can be a challenge. Again, REV. F and REV. G play a role in delineating the major differences between the kits and parts supplied with the Complete Tower Packages you purchase. As the approach to Grounding differs between the two, let's first understand which REV.# your Tower may be...

REV. F - All Self-Supporting Towers, all Bracketed Towers and those Guyed Tower Kits with a Part number containing a D between the windspeed and height designations ( ie. R-45G110D040) in the nominclature are REV. F classification and therefore will have these characteristics in common...

REV. F Tower Base Grounding - each Base Grounding Kit will come with material to bond one tower section rail to ground via a clamp, ten foot of solid copper wire and an eight foot ground rod. Depending on the Tower height and Base style, the Tower Kit may contain one, two or three of these Base Grounding Kits. For example; a ten foot Self-Supporting Tower Kit will come with one Base Rail Grounding Kit, the rest will come with two. A Bracketed Tower Kit likewise will come with the same number of Kits depending on Height. A Guyed Tower Kit will come with three of these Kits. A Tower with a Tapered Base Section will come with a Grounding Kit designed to attach via a Lug to one of the side panel plates on the section; rather than a Rail Clamp connection.

REV. F Tower Guy Grounding - each Tower Down Guy Grounding Kit will come with material to bond three Tower Down Guy Anchor locations via a Split Bolt clamp to each Down Guy Stranded Wire with 15 feet of Solid Copper wire to pass through all Split Bolt Bonds on its way to connect with one 8 foot Ground Rod.

REV. G - All Guyed Tower Kits with a a part number containing an R between the windspeed and height designations (ie. R-45G130R040) in the nomenclature are REV. G classification and will have these characteristics in common. The Base and Anchor Grounding Kits model number will end with a "GX"...

REV. G Tower Base Grounding - each Base Grounding Kit will come with material to bond one tower section rail to ground via a clamp, ten foot of solid copper wire and a ten foot ground rod. All Guyed Tower Kits will come with three of these Base Grounding Kits. Those Tower Kits with Tapered Bases will come with hardware to connect to that Base accordingly.

REV. G Tower Guy Grounding - each Tower Down Guy Grounding Kit will come with material to bond three Tower Down Guy Anchor locations via attachment to the Down Guy Anchor Rod itself with a Clamp, 15 feet of Braided Steel Wire Rope to a ten foot Ground Rod.

REV G GROUNDING REQUIREMENT FOR STRUCTURES

Rev G made signicant changes regarding the grounding requirements for structures. A prescriptive approach to grounding was used in Rev F where providing specic grounding leads and ground rods were considered adequate to protect a structure.

Rev G adopted a performance specication approach that requires providing a grounding system that will result in a maximum 10 ohm resistance to earth. Rev G also requires minimum ground lead and ground rod sizes that are greater than the Rev F prescriptive requirements.

Another change is that Rev G does not require specic grounding materials. Rev F required the use of galvanized ground rods with tinned copper leads. Rev G only requires that the leads and connections be compatible with the ground rods from a corrosion standpoint (i.e. minimize di-erence between metals connected).

Rev G does provide default grounding arrangements for various types of structures that are intended to meet the 10 ohm requirement for a wide variety of soil conditions. In accordance with Rev G, the actual resistance of a default grounding system must be veried based on site conditions. Additional ground rods or special grounding systems may be required.

It should be noted that the TIA-222 grounding requirements are meant to protect the structure and foundation from high fault currents. Other grounding requirements are often needed for the protection of antennas, radio equipment and other appurtenances.