620 Plastic Coated Steel Down Guy Wire for Antenna Mast Pole 500' feet

Price$64.95
Manufacturer Code3S-620-500
Stock Level: 272
Qty
AvailabilityUsually ships in 24 Hrs

Highlights

Ten 50 foot Hanks 500 feet Total
Plastic Coated
6 Strand 20 AWG
Perfect for Mast Guy

Bulk Quantities Available Here!

3 Star Inc 620-500 620 Plastic Coated Down Guy Wire for Antenna Mast Pole 500' Feet
This is 500 feet of Plastic Coated over Galvanized 6 Strand, 20 AWG Guy Wire for Light Duty Antenna Mast Guying. Comes in Ten contiguous 50 foot hanks for a total of 500' feet. Strip Plastic off before Terminating Down Guy ends with cable clamps.

Note

Antenna Mast Manufacturers recommend guying masts of ten feet and above in height. When Selecting Guy Wire for use in Guying Antenna Masts, Consider the Height, Antenna Size and Wind Loading being presented. This Stranded (6 Strands of 20 Gauge wire) Guy Wire is Just fine for Most all Antenna Mast Guying Scenarios, We recommend that You consider using this wire for Shorter, Lighter Load Applications Where Environmental, Insulative, and Protective Concerns are an issue.

GENERAL USE

The ROHN RSL is a light weight self-supporting tower designed for use in broadband, public safety and security applications. The RSL reaches above line-of-site obstacles such as tree tops, hilly terrain and buildings. The RSL is shipped knocked down to reduce shipping cost and time.

 

 

STRUCTURE CLASSIFICATION = I

 

 

That due to height, use or location poses a low hazard to human life and damage to property in the event of failure and/or used for services that are optional and/or where a delay in returning the services would be acceptable.

 

EXPOSURE CATEGORY = C

 

Open terrain with scattered obstructions having heights generally less than 30 ft (9.1 m) This category includes flat, open country, grasslands and shorelines in hurricane prone regions.

 

TOPOGRAPHICAL CATEGORY = 1

 

No abrupt changes in general topography, e.g. flat or rolling terrain, no wind speed-up consideration shall be required. 

 

3-SECOND GUST WIND SPEED WITH ICE = 40 MPH

 

DESIGN ICE THICKNESS = 1.0"

 

EARTHQUAKE SPECTRAL RESPONSE ACCELERATION, Ss = 2.50

 

ROHN RSL Angle Braced Class II
ROHN RSL Angle Braced Class II

The tabulated allowable effective projected areas (EPA) are limited to a maximum recommended value of 80 (ft2). EPA values shown as " - " indicate tower kit is not applicable for the corresponding wind speed. Site-specific designs are available upon request.

ANGLE BRACING
CLASS II LOADING