Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN RSL TOWER...12$33.00
Rohn RSL Tower...15$1,540.00
RASK12 Accessory...10$296.00
Telescopic...80$164.00
Rohn RSL Tower...8$1,150.00
ROHN Lightning...8$145.00
ROHN 25G Tower...1$205.00
Rohn RSL Tower...15$196.00
3 dB Power...2$3.65
ROHN 65G Tower...1$390.00
ROHN TUF TUG...8$335.00
50 Foot Telescopic...15$282.00
225 FT RG11...8$99.00
18 inch Telescopic...12$28.40
75 FT RG11...12$45.00
Rohn RSL Tower...11$1,345.00
Rohn RSL Tower...14$372.00
5' Foot X 1...20$16.30
BNC Male to...1$1.90
ROHN 24 inch...10$88.00
100 FT RG11...13$55.00
ROHN RSL 100...5$6,090.00
EZ32C Telescopic...16$24.95
Rohn RSL Tower...9$3,710.00
ROHN Universal...10$70.38
53" X 2.00"...6$17.95
ROHN Tower...3$38.00
Rohn RSL RGKG...7$430.00
RG6 Coaxial...2$12.95
EZ TM-50-U...17$164.00
ROHN RSL 100...3$6,636.00
ROHN 4 inch...17$39.00
Rohn RSL Tower...5$345.00
Complete Grounding...18$32.00
45G Main Straight...1$13.95
21" J Pipe...6$19.95
125 FT RG11...6$59.00
Gripple Tensioning...1$87.00
HOLLAND 8-Way...1$9.95
ROHN 8 inch...10$79.00
Rohn RSL Tower...6$310.00
Rohn RSL Tower...9$625.00
Dual Port Coaxial...3$1.30
ROHN 55G Tower...2$332.00
ROHN 12 inch...12$84.00
1/4" Extra...1$129.95
ROHN 55G Tower...1$1,350.00
4 inch W type...4$10.95
PLA1000 F Connecto...1$49.95
RG11 Tri-Shield...1$290.00
RG6 Underground...1$38.00
50 Foot Telescopic...17$325.00
EZ47-S1 2"...1$2.00
EZ32A Telescopic...19$21.95
1/4 inch Heavy...1$1.15
20 Foot Telescopic...1$158.00
30 inch Telescopic...21$24.95
HOLLAND 12...1$2.65
EZ32 Telescopic...11$14.95
12 inch Deluxe...1$19.95
ROHN 45G Tower...1$204.00
Turnbuckle...1$3.05
ROHN H20 Telescopi...10$75.00
Non-Penetrating...1$126.00
Rohn RSL Tower...12$592.00
ROHN 65G 40...2$5,090.00
12 inch Telescopic...12$23.50
ROHN TUF TUG...1$325.00
Rohn RSL Tower...8$156.00
LNS5000 Big...1$67.95
MCR 4-Way Horizont...1$4.60
24 inch Deluxe...15$34.95
EZ46-3 Pitch...3$3.95
HOLLAND Horz...1$4.95
Broadband Digital...2$26.95
ROHN H50 Telescopi...50$189.00
Rohn RSL Tower...10$58.00
TTRSL100 Safety...11$850.00
CTB-15 Self...1$8.95
1/8" Down...2$0.95
4 inch Heavy...15$11.95
Rohn RSL Tower...12$60.50
Thomas and...2$4.90
ROHN 25G Tower...2$260.00
ROHN 65G Anti...1$960.00
FAM-8HR 8 dB...1$2.75
RG6 RG59 RG58...1$8.95
Rohn RSWGB...13$260.00
ROHN 18 inch...10$86.00
PPC EX6 PLUS...1$0.24
ROHN 45G 30...1$1,260.00
HOLLAND 2-Way...2$2.60
RG6 Underground...1$70.00
PPC EX6WS AquaTigh...2$0.28
618 Telescopic...1$134.00
Antronix 4...2$3.60
618 Telescopic...1$10.95
HOLLAND 8-Way...1$9.95
Holland HPF...1$2.45
Digital Broadband...1$29.95
ROHN 45G 10...2$570.00
ROHN 65G 20...3$2,600.00
Non-Penetrating...2$115.00
3 Foot Roof...1$54.00
ROHN 55G Tower...1$298.00
EZ48 48" Single...1$32.95
DC Voltage...2$1.95
ROHN 45G 45...1$2,150.00
ROHN BGK2G...1$89.00
5' Foot X 1...3$16.00
ROHN 45G Self...1$595.00
EZ19B Roof...6$18.08
ROHN 65G Tower...1$425.00
RG6 Coaxial...3$3.95
ROHN 65G 10...1$1,250.00
RG6 Underground...2$62.00
RG6 Underground...1$68.00
6 inch TV Antenna...1$10.82
#12 Solid Copper...1$24.95
In-Line Cable...1$32.95
Telescopic...25$117.00
EZ30 30" Single...1$17.95
EZ DM 166-2...1$22.00
24 inch Telescopic...6$34.75
ROHN 55G Tower...1$778.50
ROHN RSL 100...3$6,400.00
Gripple 1/8"...1$6.25
ROHN 55G Tower...2$420.00
ROHN 25G Tower...2$335.00
ROHN 65G 45...1$6,253.00
9 dB 2 Port...1$2.89
Non-Penetrating...1$131.00
EZ DM 166-2...1$17.95
EZ TM-50-5U...1$115.00
30 dB 2 Port...1$2.89
Mastic Sealing...1$1.95
30 dB 1 GHz...2$2.65
ROHN 45G 55G...2$745.00
16 dB 2 Port...1$2.89
RG11 RG7 RG6...4$12.95
ROHN 25G Tower...2$97.00
SILICONE SEALANT...1$4.50
EZ TS-50 Free...1$69.95
3 inch wall...4$12.95
ROHN 25G 45G...1$318.00
50 FT RG11...2$35.00
Dual Side Arm...1$159.95
ROHN 65G 35...1$4,836.00
Thomas & Betts...1$1.50
Single Port...1$0.95
RG6 Coaxial...1$19.95
Universal Tower...1$84.00
EZ TM-20-U...1$83.00
ROHN 25G Assembly...1$186.00
ROHN Bolt Kit...1$7.50
ROHN 65g Top...2$319.95
PPC Single...2$1.25
ROHN 55G 40...2$2,005.00
Dual Port Coaxial...1$1.35
Thomas & Betts...1$8.95
Dual Port Coaxial...3$1.65
ROHN Universal...1$595.00
20 dB 2 Port...1$2.89
DS-3000 J Pipe...1$28.95
EZ60A 620 Steel...3$82.95
10' Foot X...3$28.90
ROHN TB5125BA...1$35.23
5' Foot by...1$14.50
8' Foot X 1...1$27.00
ROHN 25G 10...1$334.00
Heavy Duty...1$16.95
3 inch HDG...1$13.95
ROHN 25G 45G...2$316.00
RG6 Underground...2$34.00
ROHN 25G Tower...1$325.00
Rohn RSL Tower...1$546.00
24 dB 1 GHz...2$2.65
HOLLAND 6 dB...1$2.65
ROHN 65G 10...1$1,908.00
ROHN 25G 20...1$540.00
Six Port Keystone...1$1.05
ROHN 25G Thrust...1$78.00
HOLLAND 3-Way...1$2.60
ROHN 25G Anti...1$598.00
4 inch TV Antenna...1$12.00
ROHN Universal...1$695.00
Holland TSTL...1$24.95
Non-Penetrating...1$24.95
ROHN 65G Tower...1$1,350.00
ROHN 25G Top...1$298.00
LNS5082 RG6...1$27.95
ROHN 45G Tower...1$1,100.00
ROHN 25G Tower...1$101.00
RG11 RG7 RG6...1$24.95
ROHN 45G 40...1$1,605.00
ROHN 24 inch...1$48.00
ROHN 45G/55G...1$840.00
Channel Master...1$1.40
ROHN 25AG 45AG...1$49.00
ROHN 65G Adjustabl...1$745.00
Holland G-F81F*...1$0.39
Rack Mounted...1$99.00
Protective...1$84.00
ROHN 65G Section...1$84.95
ROHN 45G 55G...1$156.00
30 Foot Telescopic...1$206.00
20 Foot Telescopic...1$126.00
Telescopic...5$144.00
APICA AP-RCA...1$1.39
30 Foot Telescopic...1$166.00
ROHN 25G Tower...1$398.00
Goods Total934$318,650.72
View Cart Check out
Printer View Tell a Friend

ROHN 25G Complete 40 Foot 90/ 70 MPH Guyed Tower 25G90R040

Price$3,125.00
Manufacturer Code25G90R040
Top Cap:
Qty
AvailabilityItem Ships 3 to 5 days .
ShippingCan ship Canada

Highlights

Hot Dip Galvanized
Double Bolted Joints
Zig-Zag Rod Bracing
1-1/4" Steel Tubing
Side Rails
12-1/2" Equalateral
Triangular Design
Can be used in:
Guyed Config

Bulk Quantities Available Here!

ROHN 25G90R040 Complete 25G 40 Foot 90 MPH Guyed Tower

 

The 25G90R040 25G Guyed Tower Supplies the Following BOM (Less Foundation and Installation) in accordance for Use as a 40 Foot ROHN 25G Tower with EPA Ratings (Effective Projected Area) for 90 MPH (Rev. G).

 

This Tower is EPA rated for 90 MPH (Rev. G) and 70 MPH (Rev. F).

Refer to larger image for EPA Information.

 

This Kit Includes the Following: Table (1) Complete Kit List

ROHN 25G90R040

Complete 25G 40 Foot 90 MPH Guyed Tower

QUANTITY

PART NUMBER

DESCRIPTION

1

25AG2

Top Cap Tower Section

3

25G

10’ Tower Section

1

25AJBK

Bolt Kit for 25G Top Section

3

25JBK

Bolt Kit for 25G Main Tower Section

1

BPC25G

Concrete Base Plate - Standard

1

GA25GD

Guy Wire Bracket

175 Ft

3/16” EHS

7 Strand - Extra High Strength (EHS) Guy Wire – 3/16”

3

PLP-115

Yellow Plastic Guard for Guy Wire

6

BG2142

3.16” Big Grip Pre-Formed Dead-Ends

6

5/16THH

5/16” Heavy-Duty Thimble

3

1/2TBE&J

1/2” x 12” Turnbuckle – Eye to Jaw

3

TBSAFETY

Turnbuckle Safety Wire and Clamp Kit

This Kit Includes

     (1) 14001 – 1/4” Galvanized U-Bolt Clip

     (1) 1/44GW15 – 1/4” x 15’ Guy Wire

3

GAC3455TOP

Anchor Rod with 5 Hole Equalizer Plate

1

AGK1GGX

Anchor Rod Grounding Kit

This Kit Includes

     (3) 15’ of 7/16” EIP IWRC RRL

     (3) 5/8” x 10’ Galvanized Ground Rod (aka 6260)

     (3) 3/4” Clamp No. 8034 WB (aka 340016)

     (3) CPC.5/.75 – Anchor Rod Clamp

3

BGK3GGX

Tower Base Section Grounding Kit

This Kit Includes

     (1) 15’ of 7/16” EIP IWRC RRL

     (1) 5/8” x 10’ Copper Clad Ground Rod

     (1) 3/4” Ground Rod Clamp

     (1) CPC1/1.25 – Anchor Rod Clamp

3

CPC.5/.75

Anchor Rod Clamp

1

3/4x12PP

Pier Pin Insert for 25G Tapered Base

1

Assembly Guide

 

 

The 25AG2 Top Cap Tower Section is the standard top section for the 25G Series,

but can be replaced with the following: Table (2) – Top Cap Tower Options

Alternative Top Caps for the ROHN 25G Tower Series

PART NUMBER

DESCRIPTION

HEIGHT

O.D.

25AG

Top Cap Tower Section

9’

2”

25AG1

Top Cap Tower Section

9’ – 3”

1.66”

25AG2*

Top Cap Tower Section (Standard Option)

9’ – 9”

2.25”

25AG3

Top Cap Tower Section

9’ – 3 1/2”

2.25”

25AG4

Top Cap Tower Section (Accessory Shelf Top Cap)

8’ – 3/16”

FLAT

25AG5

Top Cap Tower Section

8’ – 1/2"

2.75”

 

General Information

This 25G Tower is to be used in a Guyed Configuration according to Specifications in the

ROHN Catalog.

As a Guyed Structure, a 90 MPH Rated Tower can rise to a maximum of 190 Feet. Refer to ROHN Catalog for Foundation and Grounding Detail Information.

Consult ROHN Catalog PDFs in the Specifications Tab for more ROHN 25G Tower Details.

 

This Item Ships LTL Freight ONLY...

Buyers Guide
Data Sheet
Spec Sheet
Rate this product.
Product isn't rated yet. Write a review.

ROHN 25G Guyed Towers

TIA/EIA-222-G, the national standard´s seventh revision for Steel Antenna Towers and Antenna Supporting Structures, became effective January 1, 2006. REV. F wind loading is calculated according to the Fastest-Mile Wind Speed for the structure´s location as recorded from the 1-in-50-year wind speeds encountered at that location that were constant over a distance of one mile. REV. G requires that wind loading be calculated according to the three-second-gust wind speed, allowing the tower´s design to accommodate instantaneous loads. Loadings will be determined by specific local county criteria from wind, ice, and seismic maps.
Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the 25G tower. All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance.

Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a susbstitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 25G Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.


 

ROHN Complete Tower ID Nomenclature

DESIGN NOTES:
1.
Tower designs are in accordance with ANSI/TIA-222-F-1996 and ANSI/TIA-222-G-2005, Class I Structures.
2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain.
3. Designs assume two 1/2" diameter lines on each tower face.
4. Anchor radius is from tower base to intersection of anchor rod with ground.
5. Tower designs and guy chord lengths shown are based on level ground. Initial tensions for guys in pounds at 60º Fahrenheit are shown in ( ).
6. Antenna and mounts are assumed symmetrically placed at the tower top.

PARTS LIST NOTES:
1.
Items listed are required for complete (ground) guyed towers. Base and anchor details will be required for installation on roofs or for sites located on unusual terrains and wind loading criteria, for all roof type installations.
2. Standard guys provided with each standard tower include an additional 6% length.
3. Anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.
4. Installation information and a safety package (P/N: ACWS) are included with each tower.


ROHN 25G Buyers Guide



ROHN 25G Buyers Guide


Get Adobe Reader



This Buyers Guide will answer many questions you may have on this Product Line. For more detailed information and Specification Sheets covering many aspects of Various Parts, Accessories and Installation Scenarios... Please refer to the "ROHN 25G Tower" Link appearing in the Footer of this Page Below!


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections