Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
EZ32C Telescopic...33$24.95
125 FT RG11...18$59.00
ROHN 8 inch...32$79.00
ROHN 24 inch...33$88.00
ROHN 25G Top...2$298.00
18 inch Telescopic...34$28.40
Rohn RSL Tower...25$1,540.00
30 inch Telescopic...37$24.95
ROHN 25G Thrust...1$78.00
75 FT RG11...24$45.00
12 inch Telescopic...32$23.50
ROHN 25G 20...3$540.00
HOLLAND 12...5$2.65
Holland G-F81F*...3$0.39
Rohn RSL Tower...33$372.00
225 FT RG11...27$99.00
ROHN TUF TUG...31$335.00
100 FT RG11...22$55.00
53" X 2.00"...11$17.95
50 FT RG11...31$35.00
5 Foot Heavy...2$79.95
5' Foot X 1...35$16.30
ROHN Bolt Kit...8$14.95
EZ32B Telescopic...1$11.65
Thomas and...4$0.35
EZ TM-40-U...1$139.95
24 inch Telescopic...9$34.75
EZ32A Telescopic...45$21.95
ROHN 18 inch...36$86.00
Rohn RSL Tower...20$625.00
EZ46-3PO Pitch...8$1.90
ROHN 25G Assembly...2$186.00
ROHN 25G Top...1$264.00
Heavy Duty...3$12.95
ROHN RSL 100...26$6,090.00
Adjustable...2$8.95
ROHN H40 Telescopi...5$163.00
Rohn RSL Tower...28$196.00
EZ46-3 Pitch...7$3.95
EZ TM-20-U...2$83.00
Rohn RSL Tower...25$592.00
EZ32 Telescopic...28$14.95
Rohn RSL Tower...28$1,345.00
HOLLAND LA...5$11.95
20 Foot Telescopic...1$158.00
Rohn RSL Tower...33$60.50
30 Foot Telescopic...3$206.00
Rohn RSL RGKG...32$430.00
Rohn RSL Tower...2$660.00
ROHN Lightning...35$145.00
Rohn RSL Tower...28$1,150.00
Rohn RSL Tower...25$58.00
EZ19B Roof...11$18.08
PPC EX6 PLUS...3$0.24
50 Foot Telescopic...24$282.00
ROHN H50 Telescopi...115$189.00
Rohn RSL Tower...24$156.00
Complete Grounding...29$32.00
HOLLAND 8-Way...1$9.95
Telescopic...190$164.00
12 dB 2 Port...3$2.89
RG6 Underground...2$38.00
Holland HPF...7$2.45
24 inch Deluxe...28$34.95
Rohn RSL Tower...21$345.00
Non-Penetrating...5$115.00
EZ TM-50-U...42$164.00
ROHN 4 inch...29$39.00
30 dB 2 Port...4$2.89
Turnbuckle...2$3.05
RASK12 Accessory...23$296.00
RG11 Quad Shield...20$154.95
DS-3000 J Pipe...5$28.95
ROHN 25G Antenna...2$415.00
TTRSL100 Safety...31$850.00
50 Foot Telescopic...35$325.00
ROHN 25G Adjustabl...1$203.00
ROHN NPPK Non...2$469.95
ROHN 25G Tower...1$985.00
5' Foot X 1...2$16.00
4 inch Heavy...26$11.95
ROHN TUF TUG...1$325.00
ROHN 65G Tower...2$780.00
75 Ohm F Port...125$0.45
ROHN Tower...6$38.00
ROHN 65G 10...6$1,908.00
Rohn RSL Tower...32$3,710.00
ROHN 25G Tower...3$205.00
3/16" Extra...1$110.00
ROHN Lightning...4$69.00
#12 Solid Copper...5$24.95
ROHN 12 inch...30$84.00
ROHN 25AG 45AG...5$49.00
Rohn RSWGB...30$260.00
ROHN Universal...28$70.38
Dual Port Coaxial...6$1.35
FAM-12HR 12...25$2.45
ROHN RSL TOWER...25$33.00
30 dB 1 GHz...3$2.65
BNC Male to...2$3.00
Rohn RSL Tower...25$310.00
ROHN 45G 10...2$570.00
PPC Single...5$1.25
ROHN 25G Tower...4$97.00
Telescopic...10$117.00
ROHN 55G Tower...3$420.00
MCR 3-Way Horizont...1$3.60
ROHN 45G/55G...2$558.00
4 inch W type...5$10.95
ROHN BGK2G...4$89.00
ROHN 55G Tower...3$1,350.00
YOKELESS PROJECTOR...1$104.28
HOLLAND 2-Way...2$1.60
ROHN 25G 10...5$156.00
Dual Port Coaxial...3$1.65
Protective...1$84.00
ROHN 25G Tower...1$369.00
ROHN RSL 100...17$6,636.00
BNC Male to...4$1.55
16 dB 2 Port...3$2.89
HOLLAND 9 dB...1$2.65
ROHN 25G 45G...7$210.00
ROHN 25G Accessory...2$74.00
Signal Vision...1$1.25
3 inch HDG...3$13.95
21" J Pipe...2$19.95
3S-2030 Crossover...1$29.95
3 Foot Roof...1$54.00
EZ TM-50-5U...1$115.00
ROHN 55G Tower...1$778.50
ROHN 65G 20...4$1,668.00
ROHN 45G Self...2$595.00
Non-Penetrating...4$131.00
ROHN 55G Tower...1$332.00
ROHN 65G 45...2$6,253.00
Dual Port Coaxial...10$1.30
LNS5010 Black...1$39.95
ROHN 25G 45G...5$318.00
3 inch wall...3$12.95
Universal Down...1$29.95
EZ47-S8 1.5"...2$1.45
8' Foot X 1...1$27.95
ROHN 65G 20...1$3,582.00
1/4 inch Heavy...4$1.15
ROHNJACK G...3$329.00
ROHN R-AGK1GGX...1$284.00
3 Foot Tripod...1$31.50
4 inch W type...1$10.95
ROHN 25G Tower...2$289.00
Non-Penetrating...1$126.00
Non-Penetrating...3$24.95
ROHN 65G 35...5$4,836.00
EZ48 48" Single...6$32.95
ROHN 25G Tower...3$260.00
HOLLAND HFS...2$2.50
Thomas & Betts...1$1.50
ROHN 45G 55G...4$290.00
J Pipe Adapter...1$9.95
40 Foot Telescopic...1$309.00
Telescopic...20$78.00
618 Telescopic...2$134.00
GEM4060 Adjustable...1$42.00
PPC AquaTight...2$2.95
ROHN 25G 40...3$865.00
ROHN 65G Anti...1$960.00
2 inch W type...2$10.95
HOLLAND HDA...3$189.95
Portable 3...1$27.95
3S60 620 Plastic...1$108.00
RG6 Coaxial...3$3.95
RCA Male to...1$1.10
BNC Connector...1$1.45
20 Foot Telescopic...3$126.00
45G Main Straight...1$13.95
RG6 Underground...2$34.00
ROHN TUF TUG...2$498.00
24 dB 2 Port...4$2.89
RG11 RG7 RG6...3$12.95
ROHN RSL 20...1$1,270.00
9 dB 2 Port...3$2.89
ROHN 65G Tower...2$734.00
TTRSL50 Safety...3$580.00
ROHN 25G Tower...2$7.95
FAM-3HR 3 dB...1$2.75
Thomas and...2$4.90
Aluminum Mast...1$55.00
ROHN GAS4303...1$33.00
ROHN 12 inch...1$45.00
EZ TM-30-U...5$112.00
3/8 X 4 Foot...3$16.00
ROHN 6 inch...1$39.00
ROHN 25G Tower...1$79.00
EZ47-S1 2"...1$2.00
ROHN Universal...5$695.00
Heavy Duty...1$54.95
ROHN 25G Tower...1$310.00
RG6 RG59 RG58...2$8.95
CTB-15 Self...2$8.95
FAM-16HR 16...25$2.45
Single Port...1$0.95
ROHN 25G 80...1$2,300.00
ROHN 25G Tower...3$101.00
ROHN 65G 50...1$6,607.00
30 Foot Telescopic...2$166.00
ROHN 8 inch...2$47.00
HOLLAND 6 dB...1$2.65
RG11 RG7 RG6...4$24.95
PLA1000 F Connecto...1$49.95
500 FT RG11...1$134.95
Push on F Connector...4$0.79
PPC EX6XL PLUS...4$0.26
PL-259 SO-239...1$6.59
LNS5000 Big...1$67.95
DC Voltage...5$1.95
HOLLAND HFS...2$2.25
ROHN 25G 100...2$2,585.00
ROHN 55G Tower...3$298.00
HOLLAND 16...2$2.65
ROHN 25G Tower...2$358.00
ROHN 45G Tower...1$204.00
RG11 Quad Shield...1$185.00
Coaxial Cable...2$1.95
BNC Male to...1$1.90
RG6 Underground...1$62.00
TFC RG11-OR...1$225.00
40 Foot Telescopic...1$240.00
4 inch TV Antenna...2$12.00
ROHN 65G Section...2$84.95
10' Foot X...1$27.95
ROHN 65g Top...1$319.95
6 inch TV Antenna...1$10.82
HOLLAND 20...2$2.65
APICA AP-RCA...1$1.39
Concrete Base...3$14.95
HOLLAND 2-Way...1$2.60
ROHN Leg Mounted...2$165.00
ROHN 45G 55G...3$745.00
Galvanized...1$11.95
Tower Side...1$139.95
Protective...2$24.95
24 dB 1 GHz...2$2.65
EVO1-SP-2 Cable...1$1.60
Gripple Tensioning...1$87.00
Power Passing...1$4.75
ROHN 25G Anti...2$598.00
Rohn Universal...1$49.00
12 inch Deluxe...2$19.95
Telescopic...5$120.00
8-Way Power...1$8.95
ROHN 25G Tower...1$325.00
RG6 Coaxial...1$12.95
EZ TS-50 Free...2$69.95
27 dB 2 Port...1$2.89
BNC Male to...1$1.55
3S-SQ4 Clamp...1$17.95
27" - 42" FLAT...1$118.00
EZ DM 166-2...1$22.00
ROHN 65G 30...1$3,406.00
ROHN 25G 35...1$897.00
ROHN 25G 30...1$694.00
Broadband Digital...1$26.95
Holland Electronic...1$2.95
ROHN Rubber...1$148.00
ROHN 25G Adjustabl...1$214.00
ROHN 45G Tower...1$430.00
MCR 4-Way Horizont...1$4.60
Dual Side Arm...1$159.95
ROHN 65G 40...1$5,090.00
Commscope RG11...2$230.00
ROHN 25G 50...1$1,790.00
ROHN 65G Adjustabl...1$745.00
Holland TSTL...1$24.95
Heavy Duty...1$9.95
FAM-8HR 8 dB...1$2.75
EZ60A 620 Steel...2$82.95
ROHN 65G 20...1$2,600.00
EZ60A 620 Steel...1$6.95
ROHN 65G Tower...1$390.00
ROHN RSL 100...1$6,400.00
ROHN 25G 40...1$1,639.00
3 dB Power...1$3.65
12u Wall Mountable...1$382.00
APICA AP-BNC...1$1.50
EZ30 30" Single...2$17.95
ROHN 25G 7...1$288.00
Holland G-F811...1$0.29
PPC EX6WS AquaTigh...1$0.28
ROHN 65G 40...1$4,995.00
16 AWG 2 Count...1$189.95
3 Foot Tripod...1$28.60
Aluminum Mast...1$68.00
ROHN H20 Telescopi...5$75.00
ROHN 45G Tower...1$162.00
ROHN 45G Tower...1$425.00
RCA Female...1$1.10
ROHN 24 inch...1$48.00
Goods Total2416$914,570.88
View Cart Check out

ROHN 45GSR Towers

ROHN Tower Accessories
Original OEM Plates, Brackets,
Bearings, Shelves, Hardware
Mounts and other Accessories
ROHN Tower Sections
Middle, Top Cap, Solid Rail, Base
and Specialty Tower Sections to
Build a ROHN Tower Installation

ROHN Guyed Towers
Pre-Engineered Tower Kits
TIA/EIA-222-F & TIA/EIA-222-G
Wind Speeds 70 to 130 MPH

ROHN Self Supporting Towers
ROHN G Series are available as 
self-supporting tower in Kits that
are Specifically Pre-Engineered

ROHN 45GSR Meteorological Towers
ROHN Meteorological Tower Kits
TIA/EIA-222-G Wind to 110 MPH
Structure Class II / Exposure C
ROHN 45GSR Towers, Sections, Parts and Accessories

Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the 45GSR tower. All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance.

 Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a susbstitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 45GSR Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.

 


 

ROHN Complete Tower ID Nomenclature

DESIGN NOTES:

1. Tower designs are in accordance with ANSI/TIA-222-G, Class I Structures, Topographic Category 1.

2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites

located on unusual terrain.

3. Designs assume two 7/8" diameter lines on each tower face.

4. Anchor radius is from tower base to intersection of anchor rod with ground.

5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60º Fahrenheit.

6. Antenna and mounts are assumed symmetrically placed at the tower top.

 

PARTS LIST NOTES:

1. Items listed are required for complete guyed towers.

2. Base and anchor foundations listed refer to standard foundation designations.

3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.

4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.

5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.

6. Parts lists are subject to change based on availability or revised design criteria.

 


 

ROHN 45GSR Buyers Guide



ROHN 45GSR Buyers Guide


Get Adobe Reader



This Buyers Guide will answer many questions you may have on this Product Line.

ROHN Tower series is the Workhorse of America's Large and Small Communications needs; from Governments, Institutions, Space Program, Olympics, TV AM FM Broadcast, Terrestrial Microwave to Business-Band Radio, HAM Radio Operators, to Off-Air Antenna TV and DTV Reception in Fringe areas outside the Surburban Broadcast Area. ROHN fabricates their towers from the highest quality steel. They maintain mill certification on the raw materials they receive to verify the material composition of each structural member. With a focus on quality, their fabrication facility has been awarded Certification by the American Institute of Steel Construction and the Canadian Welding Bureau. They have also been approved by the City of Los Angeles, CA and Clark County, NV as a certified fabricator. They are confident that their facility and staff can produce superior grade towers and poles that will meet your standards and weather the test of time. ROHN Towers, Accessories and their Construction/Assembly Assistance are also available via 3StarInc.com... Call 877-660-0974 at anytime for assistance.


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections