Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN TUF TUG...1$325.00
ROHN 25G 40...2$865.00
Holland G-F811...1$0.29
ROHN 24 inch...8$88.00
EZ32A Telescopic...7$21.95
ROHN 4 inch...9$39.00
12 inch Telescopic...8$23.50
PPC AquaTight...1$2.95
EZ48 48" Single...1$32.95
Rohn RSWGB...5$260.00
ROHN Lightning...7$145.00
EZ32C Telescopic...8$24.95
ROHN 18 inch...11$86.00
Rohn RSL Tower...7$156.00
Six Port Keystone...1$1.05
Rohn RSL Tower...2$1,150.00
RG6 Coaxial...1$3.95
Push on F Connector...2$0.79
Rohn RSL Tower...9$345.00
Rohn RSL Tower...7$592.00
6 inch TV Antenna...1$10.82
30 dB 1 GHz...1$2.65
ROHN RSL TOWER...4$33.00
TTRSL100 Safety...6$850.00
18 inch Telescopic...14$28.40
HOLLAND 2-Way...1$2.60
Rohn RSL Tower...1$60.50
Rohn RSL Tower...7$310.00
ROHN TUF TUG...4$335.00
HOLLAND HFS...1$2.50
ROHN 25G Tower...2$97.00
50 Foot Telescopic...5$282.00
ROHN 45G 35...2$1,715.00
EZ32 Telescopic...8$14.95
ROHN 12 inch...7$84.00
RG6 Coaxial...2$4.95
Complete Grounding...7$32.00
75 FT RG11...3$45.00
Telescopic...10$164.00
50 FT RG11...3$35.00
Holland G-F81F*...1$0.39
30 inch Telescopic...6$24.95
Rohn RSL Tower...5$1,345.00
ROHN 8 inch...5$79.00
ROHN Universal...6$70.38
4 inch Heavy...7$11.95
Dual Port Coaxial...2$1.35
ROHN NPPK Non...1$469.95
100 FT RG11...6$55.00
EZ DM 166-2...1$22.00
HOLLAND 2-Way...1$1.60
EZ TM-50-U...3$164.00
RCA Male to...1$1.10
ROHN 25G 45G...1$316.00
ROHN RSL 100...4$6,090.00
RASK12 Accessory...3$296.00
ROHN RSL 100...6$6,636.00
24 inch Deluxe...3$34.95
PPC EX6 PLUS...1$0.24
Rohn RSL Tower...8$58.00
Rohn RSL RGKG...6$430.00
EZ46-3PO Pitch...1$1.90
20 Foot Telescopic...1$158.00
ROHN 65G Tower...1$425.00
5' Foot X 1...6$16.30
50 Foot Telescopic...5$325.00
ROHN H50 Telescopi...25$189.00
Rohn RSL Tower...6$1,540.00
ROHN Tower...1$38.00
RG6 Underground...1$68.00
3S-DCP Galvanized...1$7.95
ROHN 65G 10...1$1,250.00
3 inch wall...1$12.95
PPC EX6WS AquaTigh...1$0.28
Rohn RSL Tower...1$372.00
Rohn RSL Tower...2$625.00
ROHN 25G Adjustabl...1$203.00
Non-Penetrating...2$24.95
ROHN 25G Tower...1$260.00
53" X 2.00"...2$17.95
PLA1000 F Connecto...1$49.95
ROHN Bolt Kit...2$7.50
ROHN 25G Thrust...1$78.00
75 Ohm F Port...25$0.45
30 dB 2 Port...1$2.89
225 FT RG11...2$99.00
ROHN 25G Tower...1$205.00
RG6 Underground...1$70.00
ROHNJACK G...2$329.00
Broadband Digital...1$26.95
ROHN Leg Mounted...1$165.00
ROHN 25G 45G...1$210.00
ROHN 25G Tower...1$358.00
EZ19B Roof...1$18.08
Dual Port Coaxial...1$1.30
ROHN 25G Top...1$264.00
ROHN 55G 20...1$1,405.00
Ground Mount...2$39.95
5' Foot X 1...2$16.00
ROHN 45G 20...1$915.00
RG6 Coaxial...1$6.95
3 Foot Tripod...1$36.88
Rohn RSL Tower...3$196.00
ROHN 25G 10...1$156.00
ROHN 45G 55G...1$745.00
Beacon Top...1$125.00
Thomas and...1$0.35
ROHN BGK2G...1$89.00
8' Foot X 1...1$27.95
Rohn RSL Tower...1$3,710.00
EZ46-3 Pitch...1$3.95
ROHN 25G Top...1$298.00
3 Foot Roof...1$54.00
4 inch W type...2$10.95
Non-Penetrating...1$131.00
ROHN 65G 10...1$1,908.00
16 dB 2 Port...1$2.89
3 Foot Tripod...1$31.50
HOLLAND 9 dB...1$2.65
18 inch Deluxe...1$26.95
EZ TM-30-U...1$112.00
Non-Penetrating...1$115.00
125 FT RG11...1$59.00
24 inch Telescopic...1$34.75
LNS5000 Big...1$67.95
Single Port...1$0.95
ROHN 25G Tower...1$335.00
Mastic Sealing...1$1.95
Holland Electronic...1$2.95
HOLLAND 2-Way...1$2.60
Goods Total406$145,576.77
View Cart Check out
ROHN Tower Down Guy and Anchor Materials

Tower Down Guy and Anchor Material included here are that which comprise the Kits specified by various dated and current ROHN catalogs. Reference the Pre-Engineered Kit Packages in the 25G 45G 55G 65G Buyer's Guides by Height and Wind load to build or supplement your ROHN G-Series Guyed Tower to current REV. G Specifications. New REV. G and Older REV. F Specification Sheets may be found in the various "ROHN Tower" links in the Footer section below and are made available only for study and reference. Any Departure or Questions of variance from the Pre-Engineered formats should be forwarded to and engaged by a Engineer qualified to make such determinations.

 


 

ROHN Complete Tower ID Nomenclature

GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections