Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN 25G Anti...3$598.00
Rohn RSL Tower...4$592.00
18 inch Deluxe...1$26.95
EZ TM-50-U...4$164.00
Rohn RSWGB...6$260.00
Rohn RSL Tower...4$345.00
ROHN 25G Top...1$298.00
EZ32A Telescopic...8$21.95
ROHN GAS604...1$69.95
Telescopic...15$164.00
ROHN 18 inch...5$86.00
Rohn RSL Tower...4$60.50
Holland TSTL...2$24.95
In-Line Cable...1$32.95
Rohn RSL Tower...6$196.00
50 FT RG11...3$35.00
Aluminum Mast...1$121.00
Dual Port Keystone...1$1.05
30 dB 1 GHz...1$2.65
ROHN 24 inch...5$88.00
75 Ohm F Port...50$0.45
ROHN 12 inch...4$84.00
24 inch Deluxe...4$34.95
3 inch wall...2$12.95
225 FT RG11...3$99.00
TTRSL100 Safety...5$850.00
PPC EX6 PLUS...2$0.24
HOLLAND 20...1$2.65
Rohn RSL Tower...4$1,345.00
75 FT RG11...2$45.00
Rohn RSL RGKG...2$430.00
50 Foot Telescopic...5$282.00
ROHN Lightning...3$145.00
Dual Side Arm...1$159.95
EZ19B Roof...1$18.08
Rohn RSL Tower...5$625.00
18 inch Telescopic...7$28.40
Rohn RSL Tower...6$3,710.00
EZ TS-50 Free...1$69.95
Digital Broadband...1$29.95
ROHN 25G Thrust...1$78.00
ROHN TUF TUG...1$325.00
Rohn RSL Tower...4$58.00
12 inch Telescopic...3$23.50
24 inch Telescopic...1$34.75
Rohn RSL Tower...1$156.00
ROHN RSL TOWER...3$33.00
EZ32 Telescopic...5$14.95
CAT6 Plenum...1$310.50
Complete Grounding...1$24.95
ROHN RT 120...1$14,282.00
ROHN 24 inch...1$48.00
RG6 Coaxial...1$3.95
50 Foot Telescopic...3$325.00
EZ TM-30-U...1$112.00
EZ32C Telescopic...2$24.95
ROHN 6 inch...1$39.00
4 inch Heavy...5$11.95
ROHN Universal...2$70.38
EZ TM-50-5U...1$115.00
ROHN H50 Telescopi...10$189.00
Rohn RSL Tower...5$1,540.00
ROHN 55G Tower...1$332.00
ROHN 45G Top...1$338.00
100 FT RG11...1$55.00
3S60 620 Plastic...1$108.00
Rohn RSL Tower...3$372.00
27 dB 1 GHz...1$2.65
Rohn RSL Tower...2$1,150.00
Thomas and...1$4.90
3 Foot Roof...1$54.00
Non-Penetrating...2$131.00
ROHN 8 inch...3$79.00
ROHN RSL 100...3$6,090.00
20 dB 2 Port...2$2.89
ROHN 45G Torque...1$325.00
ROHN RSL 100...3$6,636.00
RG6 Underground...1$70.00
30 Foot Telescopic...1$166.00
BNC Male to...1$1.55
Telescopic...5$120.00
EZ60A 620 Steel...1$82.95
Rohn RSL Tower...1$462.00
HOLLAND LA...1$11.95
ROHN 65G 20...1$3,582.00
B-22 Universal...1$242.00
57" Inch X...3$18.95
ROHN 4 inch...2$39.00
EZ46-3PO Pitch...2$1.90
ROHN 25G 10...1$156.00
Push on F Connector...1$0.79
125 FT RG11...3$59.00
DC Voltage...1$1.95
1/4 inch Heavy...1$1.15
30 inch Telescopic...1$24.95
Rohn RSL Tower...2$310.00
ROHN 55G Tower...1$778.50
27 dB 2 Port...1$2.89
HOLLAND 12...1$2.65
ROHN 25G Accessory...1$74.00
RG11 RG7 RG6...1$24.95
ROHN 65G Tower...1$734.00
DS-3000 J Pipe...1$28.95
3 inch HDG...1$13.95
CAT6 /RJ45...1$1.95
Aluminum Mast...1$68.00
ROHN 65G 10...1$1,250.00
ROHN 25G Tower...1$290.00
RASK12 Accessory...2$296.00
PPC EX6WS AquaTigh...1$0.28
ROHN 25AG 45AG...1$49.00
ROHN 12 inch...1$45.00
Dual Port Coaxial...1$1.30
FAM-6HR 6 dB...1$2.75
RG6 Underground...1$68.00
ROHN TUF TUG...1$335.00
ROHN 25G Tower...1$101.00
Goods Total317$133,442.36
View Cart Check out
ROHN Tower Down Guy and Anchor Materials

Tower Down Guy and Anchor Material included here are that which comprise the Kits specified by various dated and current ROHN catalogs. Reference the Pre-Engineered Kit Packages in the 25G 45G 55G 65G Buyer's Guides by Height and Wind load to build or supplement your ROHN G-Series Guyed Tower to current REV. G Specifications. New REV. G and Older REV. F Specification Sheets may be found in the various "ROHN Tower" links in the Footer section below and are made available only for study and reference. Any Departure or Questions of variance from the Pre-Engineered formats should be forwarded to and engaged by a Engineer qualified to make such determinations.

 


 

ROHN Complete Tower ID Nomenclature

GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections