Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN 18 inch...15$86.00
ROHN 65G 40...1$4,995.00
100 FT RG11...6$55.00
ROHN 12 inch...14$84.00
12 inch Deluxe...2$19.95
20 Foot Telescopic...5$158.00
225 FT RG11...10$99.00
5/8 X 8 Foot...1$24.95
F-81 Coupler...1$1.05
Channel Master...1$1.40
18 inch Telescopic...10$28.40
Holland G-F81F*...2$0.39
ROHN 25G 35...3$897.00
ROHN 25G Adjustabl...2$203.00
ROHN 25G 30...1$694.00
ROHN 25G 40...3$865.00
ROHN 65g Top...4$319.95
ROHN Bolt Kit...1$14.95
ROHN 25G Thrust...5$78.00
24 inch Telescopic...3$34.75
ROHN 25G Antenna...3$415.00
ROHN 25AG 45AG...2$49.00
ROHN 25G Adjustabl...1$186.00
50 FT RG11...11$35.00
ROHN 45G 55G...1$290.00
Holland TSTL...1$24.95
EZ46-3PO Pitch...6$1.90
EZ TM-50-5U...1$115.00
Telescopic...5$144.00
ROHN H40 Telescopi...10$163.00
HOLLAND 8-Way...1$9.95
ROHN 55FK 50...1$9,300.00
Add a Drawer...1$28.50
ROHN 25G 20...1$540.00
HOLLAND HDA...1$189.95
ROHN 24 inch...1$48.00
ROHN Lightning...7$145.00
ROHN 24 inch...17$88.00
ROHN Universal...6$70.38
50 Foot Telescopic...15$282.00
ROHN 4 inch...17$39.00
Rohn RSL Tower...9$625.00
12 inch Telescopic...15$23.50
Cat6 UTP 550...1$1.30
Rohn RSL Tower...8$1,150.00
Rohn RSL Tower...11$196.00
Telescopic...105$164.00
RASK12 Accessory...10$296.00
ROHN 65G 10...3$1,908.00
EZ TM-50-U...20$164.00
HOLLAND 12...2$2.65
TTRSL100 Safety...11$850.00
EZ32A Telescopic...14$21.95
ROHN 25G 10...4$156.00
ROHN RSL 100...8$6,090.00
EZ32C Telescopic...21$24.95
5 Foot Heavy...2$79.95
Rohn RSL Tower...11$1,345.00
4 inch Heavy...15$11.95
EZ19B Roof...3$18.08
Rohn RSL Tower...11$372.00
50 Foot Telescopic...14$325.00
ROHN RSL TOWER...8$33.00
45G Main Straight...1$13.95
Rohn RSL Tower...6$1,540.00
ROHN 55G Tower...1$1,350.00
EZ32 Telescopic...10$14.95
ROHN 25G Tower...2$335.00
ROHN H50 Telescopi...60$189.00
Rohn RSL Tower...7$345.00
ROHN 55G Tower...2$298.00
Rohn RSL RGKG...11$430.00
5' Foot X 1...20$16.30
ROHN Universal...2$695.00
125 FT RG11...12$59.00
3S60 620 Plastic...1$108.00
ROHN 25G Complete...2$4,480.00
RG11 Quad Shield...2$185.00
30 inch Telescopic...9$24.95
ROHN Bolt Kit...2$7.50
Rohn RSL Tower...11$60.50
ROHN RSL 100...6$6,636.00
Complete Grounding...14$32.00
ROHN 65G Tower...1$665.00
53" X 2.00"...7$17.95
TFC RG11-OR...1$225.00
ROHN 55G Tower...3$420.00
LNS5000 Big...3$67.95
1/4 inch Heavy...2$1.15
75 Ohm F Port...50$0.45
Rohn RSL Tower...6$592.00
EZ46-3 Pitch...3$3.95
ROHN TUF TUG...1$325.00
ROHN 25G 45G...1$316.00
Rohn RSL Tower...8$3,710.00
PLA1000 F Connecto...3$49.95
ROHN 8 inch...18$79.00
ROHN 45G/55G...1$558.00
#12 Solid Copper...3$24.95
Rohn RSL Tower...13$156.00
ROHN 25G Assembly...2$186.00
Rohn RSL Tower...10$310.00
ROHN 25G Tower...1$166.00
5' Foot X 1...3$16.00
Rohn RSWGB...8$260.00
ROHN TUF TUG...7$335.00
Holland Electronic...1$2.95
75 FT RG11...8$45.00
BNC Male to...1$2.25
21" J Pipe...1$19.95
Dual Port Coaxial...5$1.65
ROHN 65G 20...2$2,600.00
Dual Side Arm...1$159.95
Thomas and...2$0.35
HOLLAND 6 dB...1$2.65
ROHN BGK2G...1$89.00
ROHN 65G Adjustabl...1$745.00
Rohn RSL Tower...13$58.00
DC Voltage...4$1.95
EZ48 48" Single...3$32.95
HOLLAND 1 GHz...1$4.60
3 Foot Tripod...1$28.60
ROHN 45G 10...1$570.00
ROHN 65G 20...1$3,582.00
ROHN NPPK Non...3$469.95
Dual Port Coaxial...5$1.35
RG6 RG59 RG58...2$8.95
ROHN 65G 35...1$4,836.00
Telescopic...10$120.00
HOLLAND HFS...1$2.50
Telescopic...20$117.00
HOLLAND LA...2$11.95
ROHN 55FK 30...1$6,675.00
ROHN 45G 40...3$1,605.00
ROHN 45G Tower...1$240.00
618 Telescopic...1$134.00
ROHN Tower...3$38.00
ROHN 25G Tower...2$101.00
2.5" to 3.75"...1$14.50
27 dB 1 GHz...1$2.65
ROHN 25G Top...2$298.00
ASKA Mini Horz...1$2.95
40 Foot Telescopic...1$309.00
HOLLAND 2-Way...1$4.95
Protective...2$24.95
ROHNJACK G...1$329.00
Non-Penetrating...3$131.00
ROHN 55G Tower...1$778.50
3/8 X 4 Foot...2$16.00
ROHN GAS4303...2$33.00
24 dB 2 Port...1$2.89
30 dB 1 GHz...1$2.65
RG6 Underground...1$34.00
Gripple Tensioning...1$87.00
30 Foot Telescopic...1$206.00
Push on F Connector...2$0.79
ROHN 25G Tower...1$358.00
Non-Penetrating...1$115.00
8' Foot X 1...1$27.00
ROHN 25G 10...1$334.00
ROHN 25G Tower...1$290.00
3 dB Power...1$3.65
ROHN 25G Tower...1$205.00
BNC Male to...1$1.90
Gripple 1/8"...1$6.25
ROHN 65G 40...2$5,090.00
ROHN 25G Tower...1$260.00
Turnbuckle...1$3.05
Dual Port Coaxial...1$1.30
24 inch Deluxe...2$34.95
ROHN 25G 45G...4$210.00
18 inch Deluxe...1$26.95
27 dB 2 Port...1$2.89
27" - 42" FLAT...1$32.00
RG6 Underground...1$68.00
ROHN 65G Tower...2$1,350.00
ROHN 25G Anti...1$598.00
ROHN 25G Tower...2$97.00
3 Foot Roof...1$54.00
20 dB 2 Port...1$2.89
30 Foot Telescopic...1$166.00
1/8" Down...2$0.95
DS-3000 J Pipe...1$28.95
Rohn Universal...1$49.00
HOLLAND 16...1$2.65
RG11 RG7 RG6...1$24.95
Butyl Weather...1$3.20
24 dB 1 GHz...2$2.65
5' Foot by...1$14.50
Holland G-F811...1$0.29
Commscope 2...1$1.25
ROHN TB5125BA...1$35.23
ROHN 25G Complete...1$4,275.00
SILICONE SEALANT...1$4.50
Thomas & Betts...1$4.95
ROHN 65G Section...1$84.95
ROHN 25G 70...1$2,130.00
Goods Total1019$362,930.62
View Cart Check out

Sort by:

65G Camera Towers

ROHN 65G 10 Foot Camera Tower R-65SS010CT

ROHN 65G 10 Foot Camera Tower R-65SS010CT
Price$2,794.00
Manufacturer Code: 65SS010CT
Average Rating: 5
Grounding:
Qty:
Add to Cart Read More

ROHN 65G 20 Foot Camera Tower R-65SS020CT

ROHN 65G 20 Foot Camera Tower R-65SS020CT
Price$4,706.00
Manufacturer Code: 65SS020CT
Average Rating: 5
Grounding:

ROHN 65G 30 Foot Camera Tower R-65SS030CT

ROHN 65G 30 Foot Camera Tower R-65SS030CT
Price$4,395.00
Manufacturer Code: 65SS030CT
Average Rating: 5
Grounding:

ROHN 65G 40 Foot Camera Tower R-65SS040CT

ROHN 65G 40 Foot Camera Tower R-65SS040CT
Price$4,995.00
Manufacturer Code: 65SS040CT
Average Rating: 5
Grounding:

ROHN 65G 50 Foot Camera Tower R-65SS050CT

ROHN 65G 50 Foot Camera Tower R-65SS050CT
Price$6,565.00
Manufacturer Code: 65SS050CT
Average Rating: 5
Grounding:

ROHN Camera Towers

ROHN structures can be designed to be utilized for security towers and surveillance applications. Our security towers are supporting cameras at military and government installations around the world. We have both solid and tubular security tower designs and all welded or knock-down designs to meet your security needs.

The all welded 65G tower sections can support 14.5 square feet of camera in 90mph, ½" ice conditions. ROHN has standard 65G security camera towers from 10´ up to 50´. ROHN also designs site-specific towers for security applications in all wind and ice conditions. Our rigid designs limit tower top movement to help ensure camera functionality even through severe weather conditions.


STANDARD VG SELF-SUPPORTING CAMERA TOWERS (all-welded)

REV. G:

110 MPH 3-SEC GUST WIND SPEED (NO ICE),

40 MPH 3-SEC GUST WIND SPEED (3/4" ICE),

CLASS II , EXPOSURE C , TOPO CATEGORY 1

SEISMIC COEFFICIENT  S <1.0

 

ROHN 65G Camera Tower

STANDARD VG SELF-SUPPORTING CAMERA TOWERS (field bolted)

REV. G:

110 MPH 3-SEC GUST WIND SPEED (NO ICE),

40 MPH 3-SEC GUST WIND SPEED (3/4" ICE),

CLASS II , EXPOSURE C , TOPO CATEGORY 1

SEISMIC COEFFICIENT  S <1.0

 

ROHN Self Supporting Tower Rev.G

DESIGN NOTES:

1. Tower designs are in accordance with ANSI/TIA/222-G.

2. Camera and mount assumed symmetrically placed at tower top.

3. Tower design assumes one 7/8" line on each tower face.

4. Assembly drawings and standard foundation details are provided with the tower.

5. Standard foundation illustrated is for general information only and is based on Rev G presumptive clay soil parameters.

 

FEATURES:
o
Completely hot-dip galvanized after fabrication to provide absolute corrosion protection.
o Pre-engineered loading charts meet varying individual specs and site conditions.
o Typical uses include small dishes, broadband, security and two-way communication.


ROHN G-Series Self Supporting Towers



ROHN G-Series Self Supporting Towers


Get Adobe Reader



This ROHN G-Series Self Supporting Towers Guide will answer many questions you may have on this Product Line.


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections