ROHN
Made in the USA!
The ROHN 25BRKT040 40' foot 25G Wall Bracketed Tower Kit comes Complete and Pre-engineered as Specified in the ROHN Catalog for Use at the Rated Height, Antenna load and Wind Speed indicated. This 25BRKT040 Kit is comprised of (3) 10' Tower Section, (1) Top Cap Section(s), (1) 5' Base Section, (2) Brackets and Grounding Package(optional), less Foundation and Installation.
This Product Order Supplies the Following BOM (Less Foundation and Installation) in accordance for Use as a Wall Bracketed 40 Foot ROHN 25G Tower with EPA (Effective Projected Area) Ratings for 70, 80 or 90 MPH (No Ice). For more info click on the "More Info" Tab above or click here to refer to Allowable Antenna Loading
This Item Ships LTL Freight ONLY!
| INCLUDED MATERIALS WITH 25BRKT040 KIT | ||
|---|---|---|
| QUANTITY | PART NUMBER | DESCRIPTION |
| 1 | 25AG2 | Top Cap Tower Section |
| 3 | 25G | 10' Tower Section |
| 1 | 25AJBK | Bolt Kit for 25G Top Section |
| 3 | 25JBK | Bolt Kit for 25G Tower Section |
| 2 | HBUTVRO | Heavy Duty Adjustable (18 - 36") House Bracket |
| 1 | SB25G5 | 5' Base Section |
| 1 | ACWS | Anti-Climb Warning Sign |
| 1 | ASSEMBLY GUIDE | Printed Specification/Assembly Guide |
| OPTIONAL ACCESSORIES FOR 25BRKT040 KIT | ||
| QUANTITY | PART NUMBER | DESCRIPTION |
| 2 | BGK3G | Tower Base Grounding Kit /includes: (1) 10' of #4 Copper Wire (1) 5/8" x 8' Copper Clad Ground Rod (1) 5/8" Ground Rod Clamp (1) 5/16" x 2 3/8" Grade 5 HDG Bolt (1) 5/16" Hex HDG Nut (1) Hy-Lug YA4C-L4 Compression Terminal Lug |
The 25AG2* Top Cap Tower Section is the Default Standard
Top Section for the 25G Series Tower Kits.
We Offer the following Substitutions when Ordering Our Kits:
| OPTIONAL TOP CAPS FOR 25BRKT040 KIT | |||
|---|---|---|---|
| PART NUMBER | DESCRIPTION | HEIGHT | O.D. |
| 25AG | Top Cap | 9' | 2" |
| 25AG1 | Top Cap | 9' - 3" | 1.66" |
| 25AG2* | Top Cap | 9' - 9" | 2.25" |
| 25AG3 | Top Cap | 9' - 3 1/2" | 2.25" |
| 25AG4 | Flat Plate Top Cap for Thrust Bearing |
8' - 3/16" | Pre-drilled FLAT |
| 25AG5 | Top Cap | 8' - 1/2" | 2.75" |
| APL25G | Assembly Plate | 0.0 | FLAT |
The ROHN APL25G is an Assembly Plate used for Finishing Off a Tower that doesn't require an AG Top Cap Section, and for mounting Aviation Beacon Lighting, Cameras and More.(Field Drilling may be Required)
When Selecting this Top Cap OPTION, a 10' foot Standard Main Tower Section will accompany the APL25G together in Substitution of an AG Top Cap Tower Section in order to maintain the Tower Height Ordered.
This 25G Tower is to be used in a Wall Bracketed Configuration according to the Foundation Specifications and Notes.
This Height Configuration relies on a SB25G5 Embedded in a Concrete Foundation Specified by Engineering. As a Wall Bracketed, Properly Mounted Structure, a 70, 80 or 90 MPH rated 25G Tower can rise to a maximum of 100 feet.
Visit our Knowledge Base for more ROHN 25G Tower Configurations, Foundation and Grounding Detail Information.
Wall Bracketed Towers are limited in Height due to the nature of Antenna and Ice loads versus the Cantilever Nature Of Wind against them, offset by the weight of the Foundation, the cohesion of the soil, the Structural Integrity of the Load-Bearing Wall and the Method of attaching the Wall Support Brackets to same to counter Tower Tipping Point, as well as the strength of the tower members to withstand these Forces against them. ROHN Tower Kits are designed based on assumptions made regarding Windspeed, EPA (Antenna Load), Height, Standard Soil Conditions, Surrounding Environment and Duty. The Pre-packaged Kits contain the parts called for based on this Stock Design. The Stock Design of these Kits does not account for the Variations of Historic Windspeed, Number of Antenna(e) Loading at Specific Height(s), Soil Engineering recommendations, Adjacent Structures, Communications Purpose, or Geo-Political Rules, Laws and Codes That will be Applicable to Your Project. It is Recommended that you take the time to engage an local Engineer that has the expertise and available Information necessary to evaluate the ROHN Catalog Pre-engineered design for Applicability, and/or find the Tower Quote Data Sheet Form by clicking the link that appears on the Footer of this Page Below. *Per Rev G requirements, any structure greater than 10' foot requires a climber safety device.
Understanding which Grounding Kits to use for what application can be a challenge. Again, REV. F and REV. G play a role in delineating the major differences between the kits and parts supplied with the Complete Tower Packages you purchase. As the approach to Grounding differs between the two, let's first understand which REV.# your Tower may be...
REV. F - All Self-Supporting Towers, all Bracketed Towers and those Guyed Tower Kits with a Part number containing a D between the windspeed and height designations ( ie. R-45G110D040) in the nominclature are REV. F classification and therefore will have these characteristics in common...
REV. F Tower Base Grounding - each Base Grounding Kit will come with material to bond one tower section rail to ground via a clamp, ten foot of solid copper wire and an eight foot ground rod. Depending on the Tower height and Base style, the Tower Kit may contain one, two or three of these Base Grounding Kits. For example; a ten foot Self-Supporting Tower Kit will come with one Base Rail Grounding Kit, the rest will come with two. A Bracketed Tower Kit likewise will come with the same number of Kits depending on Height. A Guyed Tower Kit will come with three of these Kits. A Tower with a Tapered Base Section will come with a Grounding Kit designed to attach via a Lug to one of the side panel plates on the section; rather than a Rail Clamp connection.
REV. F Tower Guy Grounding - each Tower Down Guy Grounding Kit will come with material to bond three Tower Down Guy Anchor locations via a Split Bolt clamp to each Down Guy Stranded Wire with 15 feet of Solid Copper wire to pass through all Split Bolt Bonds on its way to connect with one 8 foot Ground Rod.
REV. G - All Guyed Tower Kits with a a part number containing an R between the windspeed and height designations (ie. R-45G130R040) in the nomenclature are REV. G classification and will have these characteristics in common. The Base and Anchor Grounding Kits model number will end with a "GX"...
REV. G Tower Base Grounding - each Base Grounding Kit will come with material to bond one tower section rail to ground via a clamp, ten foot of solid copper wire and a ten foot ground rod. All Guyed Tower Kits will come with three of these Base Grounding Kits. Those Tower Kits with Tapered Bases will come with hardware to connect to that Base accordingly.
REV. G Tower Guy Grounding - each Tower Down Guy Grounding Kit will come with material to bond three Tower Down Guy Anchor locations via attachment to the Down Guy Anchor Rod itself with a Clamp, 15 feet of Braided Steel Wire Rope to a ten foot Ground Rod.
REV G GROUNDING REQUIREMENT FOR STRUCTURES
Rev G made signicant changes regarding the grounding requirements for structures. A prescriptive approach to grounding was used in Rev F where providing specic grounding leads and ground rods were considered adequate to protect a structure.
Rev G adopted a performance specication approach that requires providing a grounding system that will result in a maximum 10 ohm resistance to earth. Rev G also requires minimum ground lead and ground rod sizes that are greater than the Rev F prescriptive requirements.
Another change is that Rev G does not require specic grounding materials. Rev F required the use of galvanized ground rods with tinned copper leads. Rev G only requires that the leads and connections be compatible with the ground rods from a corrosion standpoint (i.e. minimize di-erence between metals connected).
Rev G does provide default grounding arrangements for various types of structures that are intended to meet the 10 ohm requirement for a wide variety of soil conditions. In accordance with Rev G, the actual resistance of a default grounding system must be veried based on site conditions. Additional ground rods or special grounding systems may be required.
It should be noted that the TIA-222 grounding requirements are meant to protect the structure and foundation from high fault currents. Other grounding requirements are often needed for the protection of antennas, radio equipment and other appurtenances.