Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
Dual Port Coaxial...2$1.35
EZ32C Telescopic...8$24.95
Rohn RSL Tower...8$156.00
53" X 2.00"...4$17.95
ROHN H50 Telescopi...45$189.00
BNC Female...1$2.25
#12 Solid Copper...1$24.95
225 FT RG11...9$99.00
ROHN 24 inch...10$88.00
Rohn RSL RGKG...6$430.00
ROHN 4 inch...5$39.00
ROHN 18 inch...12$86.00
4 inch TV Antenna...3$12.00
ROHN RSL 100...2$6,090.00
100 FT RG11...4$55.00
HOLLAND 20...1$2.65
Rohn RSL Tower...7$625.00
50 Foot Telescopic...3$282.00
4 inch W type...2$10.95
ROHN 12 inch...4$84.00
Rohn RSL Tower...7$1,150.00
Rohn RSL Tower...5$60.50
5' Foot X 1...9$16.30
EZ TM-50-U...8$164.00
RASK12 Accessory...2$296.00
ROHN 25G Tower...2$97.00
HOLLAND 8-Way...1$9.95
Gripple 1/8"...1$8.95
30 inch Telescopic...9$24.95
Rohn RSL Tower...1$3,710.00
21" J Pipe...2$19.95
18 inch Telescopic...5$28.40
ROHN TUF TUG...1$325.00
Single Port...1$1.05
Telescopic...5$117.00
4 inch Heavy...8$11.95
Portable 3...2$27.95
ROHN Universal...5$70.38
Rohn RSL Tower...3$310.00
Universal Tower...1$88.00
Single Port...2$0.95
50 Foot Telescopic...6$325.00
Mastic Sealing...2$1.95
Telescopic...25$164.00
ROHN 45G 30...1$1,260.00
Rohn RSL Tower...6$58.00
75 FT RG11...6$45.00
TTRSL100 Safety...5$850.00
3 dB Power...1$3.65
24 inch Deluxe...6$34.95
ROHN Leg Mounted...1$165.00
ROHN Bolt Kit...1$14.95
EZ32 Telescopic...8$14.95
9 dB 2 Port...1$2.89
HOLLAND LA...3$11.95
Rohn RSL Tower...4$1,345.00
Complete Grounding...5$32.00
EZ32A Telescopic...5$21.95
12 inch Telescopic...4$23.50
Holland HPF...2$2.45
EZ19B Roof...2$18.08
ROHN 25G Top...2$298.00
HOLLAND 6 dB...2$2.65
EZ46-3 Pitch...2$3.95
Rohn RSL Tower...4$345.00
EZ46-3PO Pitch...5$1.90
RG6 RG59 RG58...1$8.95
30 dB 2 Port...2$2.89
ROHN 25G Tower...1$290.00
ROHN 45G Tower...1$204.00
ROHN 25G Thrust...2$78.00
ROHN RSL 100...5$6,636.00
125 FT RG11...1$59.00
ROHN 8 inch...4$79.00
Heavy Duty...1$54.95
Rohn RSL Tower...13$592.00
30 Foot Telescopic...1$206.00
Thomas and...2$0.35
ROHN 65G 20...1$3,582.00
APICA AP-RCA...1$1.39
Rohn RSWGB...2$260.00
ROHN 65G 30...1$3,406.00
ROHN Bolt Kit...2$7.50
ROHN Lightning...5$145.00
1/4 inch Heavy...1$1.15
50 FT RG11...4$35.00
Dual Port Coaxial...1$1.65
ROHN 25G 30...2$694.00
ROHN Tower...3$38.00
10' Foot X...1$27.95
20 Foot Telescopic...1$158.00
ROHN 45G 35...1$1,715.00
ROHN RSL TOWER...5$33.00
ROHN 55G 45...1$2,640.00
LNS5010 Black...1$39.95
DC Voltage...1$1.95
Rohn RSL Tower...4$196.00
Telescopic...5$120.00
ROHN 55G 40...1$2,005.00
ROHN 45G 45...1$2,150.00
Gripple 1/8"...1$6.25
ROHN 65G Tower...2$734.00
Dual Side Arm...1$159.95
ROHN 45G/55G...1$558.00
Rohn RSL Tower...4$1,540.00
ROHN 25G Tower...1$260.00
RG6 Underground...2$68.00
Rohn RSL Tower...1$372.00
J Pipe Adapter...1$9.95
3 inch wall...2$12.95
ROHN 25G Side...1$43.00
ROHN 25G Accessory...2$74.00
ROHN 45G Complete...1$7,350.00
ROHN 65G 40...1$5,090.00
ROHN TUF TUG...4$335.00
10' Foot X...1$27.00
ROHN 65G 35...1$4,836.00
HOLLAND 9 dB...2$2.65
24 inch Telescopic...2$34.75
BNC Male to...1$1.55
ROHN BGK2G...1$89.00
RCA Male to...1$0.99
5' Foot by...1$14.50
75 Ohm F Port...25$0.45
RG6 Underground...1$70.00
Non-Penetrating...1$115.00
PPC EX6XL PLUS...2$0.26
ROHN 25G Tower...1$358.00
EZ48 48" Single...1$32.95
Non-Penetrating...1$24.95
30 Foot Telescopic...1$166.00
FAM-12 dB In...1$2.25
ROHN 25G 20...1$540.00
Aluminum Mast...1$121.00
Adjustable...1$8.95
ROHN 55G Tower...1$1,350.00
ROHN 55G Tower...1$332.00
ROHN 45G Tower...2$1,100.00
Goods Total481$167,195.98
View Cart Check out
ROHN Tower Down Guy and Anchor Materials

Tower Down Guy and Anchor Material included here are that which comprise the Kits specified by various dated and current ROHN catalogs. Reference the Pre-Engineered Kit Packages in the 25G 45G 55G 65G Buyer's Guides by Height and Wind load to build or supplement your ROHN G-Series Guyed Tower to current REV. G Specifications. New REV. G and Older REV. F Specification Sheets may be found in the various "ROHN Tower" links in the Footer section below and are made available only for study and reference. Any Departure or Questions of variance from the Pre-Engineered formats should be forwarded to and engaged by a Engineer qualified to make such determinations.

 


 

ROHN Complete Tower ID Nomenclature

GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections