Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
20 Foot Telescopic...1$158.00
100 FT RG11...7$55.00
Add a Drawer...1$28.50
ROHN 65G 30...1$3,406.00
EZ19B Roof...1$18.08
1/4 inch Heavy...1$1.15
24 inch Telescopic...5$34.75
ROHN 65G 20...2$2,600.00
ROHN 18 inch...7$86.00
EZ32A Telescopic...18$21.95
ROHN TUF TUG...1$325.00
7/16 inch Heavy...1$3.95
ROHN Tower...1$29.95
18 inch Telescopic...18$28.40
EZ32C Telescopic...8$24.95
ROHN Universal...13$70.38
ROHN 65G Tower...1$1,350.00
EZ32 Telescopic...8$14.95
4 inch W type...1$10.95
75 FT RG11...8$45.00
Dual Port Coaxial...3$1.30
ROHN 65G 55...1$6,864.00
50 FT RG11...11$35.00
EZ TM-50-5U...1$115.00
ROHN 25G Side...1$43.00
Power Passing...1$4.95
ROHN 3 Foot...1$87.00
ROHN 25G 20...2$540.00
225 FT RG11...8$99.00
ROHN 25AG 45AG...4$49.00
Rohn RSWGB...9$260.00
Push on F Connector...1$0.79
Complete Grounding...11$32.00
ROHN Bolt Kit...1$7.50
Rohn RSL Tower...9$3,710.00
Rohn RSL Tower...5$310.00
ROHN 24 inch...11$88.00
3/4 Inch Ground...1$3.80
ROHN 25G Thrust...1$78.00
ROHN TUF TUG...8$335.00
EZ TM-50-U...10$164.00
4 inch Heavy...15$11.95
Rohn RSL Tower...16$1,150.00
30 dB 1 GHz...2$2.65
Rohn RSL Tower...10$58.00
DS-3000 J Pipe...1$28.95
30 Foot Telescopic...2$206.00
125 FT RG11...9$59.00
30 inch Telescopic...13$24.95
Telescopic...60$164.00
30 dB 2 Port...2$2.89
EZ30 30" Single...1$17.95
ROHN RSL TOWER...8$33.00
Rohn RSL Tower...8$196.00
12 inch Telescopic...9$23.50
Rohn RSL Tower...10$345.00
Rohn RSL Tower...5$60.50
3S60 620 Plastic...1$108.00
5' Foot X 1...9$16.30
Rohn RSL Tower...9$1,540.00
EZ60A 620 Steel...1$82.95
ROHN 65G Tower...3$734.00
RG11 RG7 RG6...2$24.95
PPC AquaTight...2$2.95
ROHN 25G Tower...2$101.00
ROHN 4 inch...12$39.00
50 Foot Telescopic...10$325.00
Rohn RSL Tower...6$592.00
Non-Penetrating...2$115.00
Rohn RSL RGKG...8$430.00
4 inch W type...2$10.95
RASK12 Accessory...9$296.00
EZ46-3PO Pitch...4$1.90
40 Foot Telescopic...1$240.00
ROHN 8 inch...10$79.00
RG11 Quad Shield...1$185.00
6 inch TV Antenna...2$10.82
ROHN 12 inch...19$84.00
ROHN Lightning...10$145.00
LNS5000 Big...2$67.95
Rohn RSL Tower...7$156.00
PPC EX6WS AquaTigh...3$0.28
Rohn RSL Tower...9$372.00
ROHN H50 Telescopi...40$189.00
27 dB 1 GHz...1$2.65
ROHN 65g Top...1$319.95
ROHN 65G 40...1$5,090.00
75 Ohm F Port...25$0.45
Rohn RSL Tower...5$1,345.00
50 Foot Telescopic...14$282.00
24 inch Deluxe...13$34.95
ROHN 55G Tower...2$778.50
Rohn RSL Tower...6$625.00
ROHN Tower...3$38.00
Thomas & Betts...1$4.95
4 inch TV Antenna...1$12.00
ROHN 65G 10...2$1,908.00
ROHN 25G Tower...2$335.00
ROHN 45G Tower...1$204.00
ROHN 45G 55G...2$290.00
21" J Pipe...2$19.95
ROHN 18 inch...1$47.00
Telescopic...10$117.00
ROHN 45G Tower...2$240.00
8' Foot X 1...2$27.95
20 Foot Telescopic...1$126.00
ROHN 24 inch...1$48.00
45G Main Straight...1$13.95
HOLLAND 9 dB...1$2.65
ROHNJACK G...2$329.00
HOLLAND 16...1$2.65
3 dB Power...1$3.65
ROHN RSL 100...10$6,636.00
30 Foot Telescopic...2$166.00
Mastic Sealing...1$1.95
RG6 Coaxial...1$3.95
ROHN Tower...1$63.00
3/8 X 4 Foot...2$16.00
Non-Penetrating...5$131.00
Coaxial Cable...1$1.95
ROHN 45G Self...1$595.00
618 Telescopic...2$134.00
3 inch HDG...2$13.95
Thomas and...1$0.35
ROHN 65G Tower...2$390.00
F-81 3 GHz...1$1.50
TTRSL100 Safety...4$850.00
ROHN 25G Accessory...1$74.00
ROHN 25G 40...4$865.00
RG6 Coaxial...1$6.95
3 inch wall...1$12.95
ROHN 45G 35...1$1,715.00
Aluminum Mast...1$121.00
EZ46-3 Pitch...2$3.95
Protective...1$24.95
3S-MCP Galvanized...1$10.95
ROHN RSL 100...6$6,090.00
Non-Penetrating...1$99.56
ROHN 45G Tower...1$1,100.00
ROHN 25G Tower...1$358.00
ROHN Tripod...1$284.00
ROHN 65G 20...2$3,582.00
RG6 Underground...1$38.00
10' Foot X...1$28.90
ROHN 25G Tower...1$97.00
ROHN 25G Tower...1$7.95
Banana Plug...1$3.50
53" X 2.00"...5$17.95
LNS5010 Black...1$39.95
ROHN 25G Complete...1$4,480.00
Commscope 2...1$1.25
Holland G-F81F*...1$0.39
EZ TM-30-U...1$112.00
ROHN 25G 30...1$694.00
ROHN H40 Telescopi...5$163.00
APICA AP-BNC...1$1.50
BNC Male to...1$4.95
ROHN 65G Tower...2$665.00
ROHN 25G 45G...2$210.00
FAM-3 dB In...1$2.25
RG6 Underground...1$34.00
Adjustable...1$8.95
ROHN Bolt Kit...1$14.95
Holland HPF...1$2.45
ROHN 65G 60...1$7,150.00
ROHN Universal...1$595.00
HOLLAND HDA...1$189.95
Six Port Keystone...1$1.05
ROHN 45G 30...1$1,260.00
Dual Port Coaxial...1$1.65
ROHN RSL 100...1$6,400.00
DC Voltage...1$1.95
5/8 inch Round...1$14.95
HOLLAND 20...1$2.65
2 inch W type...1$10.95
12 dB 2 Port...1$2.89
HOLLAND 12...1$2.65
Broadband Digital...1$26.95
Holland G-F811...1$0.29
Dual Port Coaxial...2$1.35
1 HDMI + 3...1$18.00
3S-FRM-150...1$110.00
ROHN 55G 40...1$2,005.00
40 Foot Telescopic...1$309.00
ROHN 55FK 40...1$8,200.00
BNC Connector...1$1.45
Goods Total782$337,547.15
View Cart Check out
ROHN Tower Down Guy and Anchor Materials

Tower Down Guy and Anchor Material included here are that which comprise the Kits specified by various dated and current ROHN catalogs. Reference the Pre-Engineered Kit Packages in the 25G 45G 55G 65G Buyer's Guides by Height and Wind load to build or supplement your ROHN G-Series Guyed Tower to current REV. G Specifications. New REV. G and Older REV. F Specification Sheets may be found in the various "ROHN Tower" links in the Footer section below and are made available only for study and reference. Any Departure or Questions of variance from the Pre-Engineered formats should be forwarded to and engaged by a Engineer qualified to make such determinations.

 


 

ROHN Complete Tower ID Nomenclature

GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections