Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
ROHN 25SS040...2$898.00
ROHN WM12D...2$84.00
1.66" inch...1$17.95
ROHN ACL25G...1$636.00
ROHN WM18D...1$86.00
ROHN JRM27555...1$585.00
1.25" inch...1$52.00
175 FT RG11...1$79.00
Non-Penetrating...1$110.00
Rohn RSL Tube...3$720.00
Rohn RSL Tube...1$850.00
VMP Antenna...1$110.95
Adjustable...1$32.50
Rohn RSL Tube...1$768.00
ROHN 25SS035...1$950.00
Rohn RSL Tube...1$860.00
5' Foot Antenna...1$16.30
Rohn RSL Tube...1$870.00
Harger CPC1...1$44.95
Goods Total23$10,192.65
View Cart Check out

Categories

Printer View Tell a Friend

Harger CPC1.5/2 Clamp for Grounding ROHN 65G 55G Tower and Base Sections

× Harger CPC1.5/2 Clamp for Grounding ROHN 65G 55G Tower and Base Sections was added to your Shopping Cart.
Price$44.95
Manufacturer CodeCPC1.5/2
Qty
AvailabilityUsually ships in 24 Hrs

Highlights

For Ground Connection to:
65G/55G Main Tower & Base Sections
1.5" to 2" OD Pipe
Electroplated Tinned Bronze
Fits Conductors #6 Solid-250 MCM
Quick Connect Bi-Directional Design
UL Listed
Acceptable for Direct Burial

Bulk Quantities Available Here!

ROHN CPC1.5/2 Clamp for Grounding 55G 65G Tower and Base Sections
Made in the USA!Made in the USA!
The CPC1.5/2 Clamp is for Solid and Stranded Copper Wire and Stranded Wire Rope Grounding Connections to the 55G and 65G Main Tower Sections and Fixed Rigid Bases by means of affixing these 1.5 to 2.00 inch range Clamps around at any one of the (3) Tubular Rail (1.25" - 2.4" OD actual range) components at the lowest visible point possible above grade and in closest proximity to the Ground intended for use as to shorten the wire distance between as much as possible. The Lug also mates the connection to Solid/Stranded Copper or 7/16 6x25 EIP IWRC RRL Wire Rope as supplied in the BGK3GGX REV. G Grounding Kits (not included).
Harger CPC Pipe Ground Clamps compare to Burndy GAR

Made to connect to any of the three Leg Rail components of a 55G and 65G Main Tower or Fixed Rigid Base Sections in a Typical Tower Installation as these Tubes are within the nominal OD range above. This Clamp will also connect the Solid or Stranded Copper Ground Wire lead to the Ground Rod on the other end, completing your Grounding (Lightning Protection) System. Typically, 3 of these Clamps are used as most Systems will dictate that a separate Ground Connection be made to all three Tower Rail Tubes.

Buyers Guide
Spec Sheet
Data sheet

Telescoping Antenna Mast Mounts Accessories and Replacement Parts

Remember those older AM/FM Portable Radios with the antenna that you extended by pulling it out? Or the Radio Antennas on older cars that would pop- out, extend and retract when you turned on the radio? This Mast isn't an Antenna, but it extends and retracts by hand in similar fashion. Available in 20', 30', 40' and 50' heights. All ROHN telescoping masts are pre-galvanized and come assembled with hardware. Erection is made by simply connecting guys and brackets to the attached unique heavy duty rolled edge guy rings and clamps, extend each section one at a time (starting with the innermost section), insert the locking cotter pins, rotating the tubes to a locked position, and tightening the clamps. Repeat the process on each successive section until fully erect.

The unique ROHN Products design features interior tube flanging combined with a double crimped exterior tube to produce a stronger and more stable joint than most common masts. This design exclusive also prevents the sections from accidentally pulling apart and allows disassembly by pulling each section out through the lower end.
Each section extends deeper in to the lower tubes than most other designs, adding still further to the stability of the structure.

H Series
This heavy duty series uses 1-1/4" 16 gauge galvanized tubing for top section. All other sections are 18 gauge.

Assembly
1. Secure base and anchors (sold separately).
2. Attach lowered mast to base.
3. Secure guy lines to the lower Guy Ring and attach to anchors. Align the mast vertically by tightening the Guy Lines.
4. Secure upper Guy Ring using the appropriate Mast Clamp to desired location on the upper Tube (see note 8 on page 10).
5. Secure appropriate length guy lines to the upper Guy Ring and let them hang.
6. Raise the upper Tube and inset the cotter pin. Make sure that the cotter pin is inside the notch in the inside tube.
7. Secure the cotter pin and tighten the mast clamp.
8. Secure appropriate length guy lines to the next highest Guy Ring, and let them hang.
9. Raise the next smallest Tube and insert the cotter pin. Make sure that the cotter pin is inside the notch in the inside tube.
10. Secure the cotter pin and tighten the mast clamp.
11. Repeat steps 8-10 until all sections have been raised and are secured.
12. Attach all hanging Guy Lines to their respective anchor. Align the mast vertically by tightening the Guy Lines. Make sure to work your way up the mast while tightening.


ROHN Telescoping Masts

ROHN H-Series Masts

 

This Buyers Guide has will answer many questions you may have on this Product Line. For more detailed information and Specification Sheets covering many aspects of Various Parts, Accessories and Installation Scenarios. Please refer to the "Telescopic Mast" Link appearing in the Footer of this Page Below!
Telescoping Masts are not recommended for commercial, CB or beam antenna installations.