Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
ProductQtyPrice
10 Foot Tri-Mount...1$59.95
Goods Total1$59.95
View Cart Check out

Categories

Printer View Tell a Friend

ROHN 45SR030 30' foot 45GSR Self-Supporting Tower Complete Pre-engineered Kit

Price$4,200.00
Manufacturer Code45SR030
Top Cap ..:
Grounding:
Stock Level: 5
Qty
AvailabilityIn stock call 804-550-7202 or request Freight Quote
Oversized Item - Request Freight Quote
Request Quote
Call (804) 550-7202
Email info@3starinc.com

Highlights

Hot Dip Galvanized
Flange Bolted Joints
Zig-Zag Rod Bracing
1-1/4" Solid Steel
Side Rails
16 3/4" Equilateral
Triangular Design
Can be used in:
Self Support Config

Bulk Quantities Available Here!

ROHN 45SR030 30' foot 45GSR Self-Supporting Tower Complete Pre-engineered Kit
Made in the USA!Made in the USA!
The ROHN 45SR030 30' foot 45GSR Self-Supporting Tower Kit comes Complete and Pre-engineered as Specified in the ROHN Catalog for Use at the Rated Height, Antenna load and Wind Speed indicated. This 45SR030 Kit is comprised of (1) 20' 45GSR20 Tower Section, (1) 10' 45GSR10 Tower Section, (1) 4' 45GSRSB Short Base Section and Grounding Package (optional), less Foundation and Installation.

This Product Order Supplies the Following BOM (Less Foundation and Installation) in accordance for Use as a Self Supporting 30 Foot ROHN 45GSR Tower with EPA (Effective Projected Area) REV. F Ratings for 70, 80 or 90 MPH (No Ice) and REV. G Ratings for 90, 100 or 110 MPH (No Ice) 3-second Gust Wind Speeds. For more info click on the "More Info" or "Specification" Tabs above.
This Item Ships Dedicated Flatbed Freight ONLY!
Please Contact 3 Star Inc. directly for a Freight Quote.

 

THIS 45SR030 KIT INCLUDES THE FOLLOWING + OPTIONS
INCLUDED MATERIALS WITH 45SR030 KIT
QUANTITY PART NUMBER DESCRIPTION
0 None Required See Top Cap/Plate Options Below
1 45GSR10 10' foot 45GSR Tower Section
1 45GSR20 20' foot 45GSR Tower Section
2 45GSRHDW Bolt Kit for 45GSR Tower Section
1 45GSRSB 4' 45GSR Short Base Section
1 ACWS Anti-Climb Warning Sign
1 ASSEMBLY GUIDE Printed Specification/Assembly Guide
OPTIONAL ACCESSORIES FOR 45SR030 KIT
QUANTITY PART NUMBER DESCRIPTION
2 BGK3G Tower Base Grounding Kit /includes:
(1) 10' of #4 Copper Wire
(1) 5/8" x 8' Copper Clad Ground Rod
(1) 5/8" Ground Rod Clamp
(1) 5/16" x 2 3/8" Grade 5 HDG Bolt
(1) 5/16" Hex HDG Nut
(1) Hy-Lug YA4C-L4 Compression Terminal Lug

 

None is the Default Selection for a Top Cap or Plate as there
are no Top Cap Sections in the 45GSR Series Tower Series.
The Rails are Solid, not Hollow, and Terminate to Flanges.
We Offer These Optional Caps and Plates when Ordering:

TOP CAP AND PLATE OPTIONS
OPTIONAL TOP CAPS / PLATES FOR 45SR030 KIT
PART NUMBER DESCRIPTION HEIGHT Mast OD
APL4A Assembly Plate and Accessory Mount 0' N/A
45GSRTTA Tapered Cap with Mast Stub 13.5" 2.375"
BPL45GSR Thrust Bearing Plate 0' N/A
Lightning Rod+Cap (1) LRCL + (1) VW132 Mount 0' N/A

 

Note

Self-Supporting Towers are limited in Height due to the nature of Antenna and Ice loads versus the Cantilever Nature Of Wind against them, offset by the weight of the Foundation and the cohesive of the soil to counter a Tower tip-over moment, as well as the strength of the tower members to withstand these Forces against them. ROHN Tower Kits are designed based on assumptions made regarding Windspeed, EPA (Antenna Load), Height, Standard Soil Conditions, Surrounding Environment and Duty. The Pre-packaged Kits contain the parts called for based on this Stock Design. The Stock Design of these Kits does not account for the Variations of Historic Windspeed, Number of Antenna(e) Loading at Specific Height(s), Soil Engineering recommendations, Adjacent Structures, Communications Purpose, or Geo-Political Rules, Laws and Codes That will be Applicable to Your Project. It is Recommended that you take the time to engage an local Engineer that has the expertise and available Information necessary to evaluate the Stock design for Applicability, and/or find the Tower Quote Data Sheet Form by clicking the link that appears on the Footer of this Page Below. *Per Rev G requirements, any structure greater than 10' foot requires a climber safety device.

Specification Sheet
45GSR SS Spec. Sheet
BGK2G Grounding
ROHN SS Guidelines
Buyers Guide
45GSR SS Buyers Guide
Loading G-SS REV H
Tower Design REV G

ROHN 65G Guyed Tower with Complete Kits

TIA/EIA-222-G, the national standard´s seventh revision for Steel Antenna Towers and Antenna Supporting Structures, became effective January 1, 2006. REV. F wind loading is calculated according to the Fastest-Mile Wind Speed for the structure´s location as recorded from the 1-in-50-year wind speeds encountered at that location that were constant over a distance of one mile. REV. G requires that wind loading be calculated according to the three-second-gust wind speed, allowing the tower´s design to accommodate instantaneous loads. Loadings will be determined by specific local county criteria from wind, ice, and seismic maps.
Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the 65G tower. All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance.

Wind Loading, Antenna Loading and Wind Survivability ratings vs. Height Documentation Provided by ROHN is available here as a Resource, but is by no means complete by itself or a substitution for Engineering Conducted Specific to your Application. Contact Us with any Questions you may have regarding Use prior to Purchase. All Information regarding the ROHN 65G Tower line, Parts and Accessories is as accurate and complete as we can possibly provide given that this Resource Offering is subject to change without Notice and is beyond Our Control.


ROHN Complete Tower ID Nomenclature

DESIGN NOTES:
1.
Tower designs are in accordance with ANSI/TIA-222-F-1996 and ANSI/TIA-222-G-2005, Class I Structures, Topographical Category 1.
2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain.
3. Designs assume two 7/8" diameter lines on each tower face.
4. Anchor radius is from tower base to intersection of anchor rod with ground.
5. Tower designs and guy chord lengths shown are based on level ground. Initial tensions for guys in pounds at 60º Fahrenheit are shown in ( ).
6. Antenna and mounts are assumed symmetrically placed at the tower top.

PARTS LIST NOTES:
1.
Items listed are required for complete (ground) guyed towers.
2. Base and anchor foundations listed refer to standard foundation designations.
3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.
4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.
5. Assembly Drawings and a safety package (P/N: ACWS) are included with each tower.
6. Parts lists are subject to change based on availability or revised design criteria.


ROHN 65G Buyers Guide

ROHN 65G Buyers Guide

 

This Buyers Guide will answer many questions you may have on this Product Line.

ROHN Tower series is the Workhorse of America's Large and Small Communications needs; from Governments, Institutions, Space Program, Olympics, TV AM FM Broadcast, Terrestrial Microwave to Business-Band Radio, HAM Radio Operators, to Off-Air Antenna TV and DTV Reception in Fringe areas outside the Suburban Broadcast Area. ROHN fabricates their towers from the highest quality steel. They maintain mill certification on the raw materials they receive to verify the material composition of each structural member. With a focus on quality, their fabrication facility has been awarded Certification by the American Institute of Steel Construction and the Canadian Welding Bureau. They have also been approved by the City of Los Angeles, CA and Clark County, NV as a certified fabricator. They are confident that their facility and staff can produce superior grade towers and poles that will meet your standards and weather the test of time. ROHN Towers, Accessories and their Construction/Assembly Assistance are also available via 3StarInc.com. Call 877-660-0974 at anytime for assistance.


GUIDELINES FOR THE PREPARATION OF A GEOTECHNICAL REPORT

I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a Geotechnical Engineer.

b) It is not ROHN´s purpose or intent to supercede the Geotechnical Engineer´s knowledge, judgement and/or experience. It is the Geotechnical Engineer´s responsibility to add or delete from these items, based on local site conditions and other factors.

c) Additional information is provided in ANSI/TIA-222-G Annex G "Geotechnical Investigations".

II. DISCLAIMER

a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS

a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers. For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken at each tower leg. A "small" self-supporting tower is assumed to have a face width less than 20 feet and a compression load less than 50 kips per leg. For pole structures, one boring may suffice.

b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.

c) If borings cannot be advanced to the desired depth, rock core samples should be taken. Rock Quality Designation (RQD) values and compressive strengths should be determined.

IV. GEOTECHNICAL REPORT

a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and summarized in the geotechnical report:

1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. "In-Situ" soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions

b) The following items should be discussed in the geotechnical report:

1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections