Towers | Poles | Mounts | Masts | Hardware | Guy | Cable | Wire | Carts | Racks | Tools
Your Cart
Your shopping cart is empty!
Printer View Tell a Friend

ROHN VW132 Lightning Rod Plate Kit for 45GSR Series Tower Cap Installation

Price$39.95
Manufacturer CodeVW132
Stock Level: 41
Qty
AvailabilityShips in 1 to 3 Days

Highlights

Hot Dip Galvanized
Flange Bolted Joints
Can be used in:
Guyed, Self Supporting
and Bracketed Config.s

Bulk Quantities Available Here!

ROHN VW132 Lightning Rod Plate Kit for 45GSR Series Tower Cap Installation
Made in the USA!Made in the USA!
The VW132 kit is comprised of (1) 3/16" inch thick Plate with bolts and nuts for installation onto a 45GSR Tower Section leg joint flange as an Assembly for (1) Leg with an additional Hole predrilled for the LRCL Lightning Rod.(available separately). Addition Top Caps are not included in this Kit as only One Lightning Rod is needed and with the leg rails of the Tower section being solid, there is no further need of additional caps to seal from Animal, Insect or Debris accumulation.

Specifications
grounding type
Grounding Kits

Ground your Coaxial Cable System

Commensurate with Coaxial Cable TV Antenna and Satellite TV Splitter Installation, you want to Ground your Cable TV or HDTV Antenna Coaxial Cable System Outside before bringing the TV Cable Inside. This way, Lightning Strikes and Power Surges have an opportunity to arrest before reaching your Satellite Receiver and TV Set(s). The Integral Grounding Block designed onto most Outdoor Use Compatible Satellite Signal Splitter we sell will effectively convey this unwanted Electrical Energy to a Ground Rod via a Copper Ground Wire that you Install (not included). Consult your Local Building Code and NEC for guidance to Properly Grounding your HD TV Antenna, Satellite TV, Cable TV, WI-FI, Wireless Internet, Business Band, CB or Amateur Radio Antenna Installation.

Grounding & Bonding Are Important

Ground Blocks and Proper Grounding are an Important, often overlooked, aspect of Your Over-all Cable TV, HDTV or Satellite Antenna Installation and Safety. Proper Grounding can also Reduce the Reception of Interfering RF Signals. Grounding of Masts, Antennas, Cable TV and other RF Distribution Systems are covered by the NEC. Grounding can be as simple as a 12 AWG Ground Wire connected a short distance away to a 8 foot 5/8" DIA Copper Ground Rod (not supplied) or Bonded to the Existing Power Ground by the Power Meter installed on the side of your Home or Office. You may notice that most new Cable TV, Satellite and TV Antenna Installations are effected in this Manner. However, most State and some Local codes will contain requirements that supersede that of the NEC. Please Refer to Your Local Building and Electrical Codes.